Failure study of secondary superheater tube out header damage in a 600-MW coal power plant

被引:7
|
作者
Nurbanasari, Meilinda [1 ]
Abdurrachim [2 ]
Pramono, Bowo [3 ]
Darmadi, I. Gede [3 ]
Saputro, Iwan Toni [1 ]
Gumilar, Gugum [1 ]
Ekajati, Alfan [1 ]
机构
[1] Inst Teknol Nas Bandung, Dept Mech Engn, Bandung, Indonesia
[2] Univ Pasundan, Dept Mech Engn, Bandung, Indonesia
[3] PT PLN Indonesia Power Suralaya Power Generat Unit, Kota Cilegon, Indonesia
关键词
Out header secondary superheater; Scale; Overheating; Bursting; SUPER-HEATER; BOILER; EXFOLIATION; OXIDATION;
D O I
10.1016/j.engfailanal.2023.107349
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Herein, a failure analysis of the out header of a secondary superheater tube in a 600-MW coal-fired power plant that has been operating for the past 26 years was performed. This type of failure generally results in the plant being shut down. Therefore, it is crucial to identify the cause of the failure to determine the necessary action to be taken and to avoid similar failures in future. The investigation involved visual inspection, chemical composition analysis, microstructure analysis, hardness test, and deposit analysis. It was found that the tube failed with a bending and burst opening and experienced an increase in hardness in the fractured area. There was no sig-nificant difference between the microstructures of the fractured area and other areas located away from the fractured area. The X-ray diffraction and scanning electron microscopy and energy-dispersive X-ray spectroscopy results confirmed the presence of a magnetite layer (scale) on the inner wall tube, and the layer thickness ranged 293-345 mu m, which exceeded the peeling critical thickness value of 160 mu m. The failure resulted from the exfoliation of the magnetite layer on the inner wall tube, which blocked the flow of steam in the U-bend. The tube blockage caused local overheating, which reduced the maximum allowable stress until the bursting.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Failure analysis of a reheater tube dissimilar metal weld failure in a 500 MW power plant
    Varma, Anand
    Yadavalli, Ravi Kumar
    ENGINEERING FAILURE ANALYSIS, 2020, 118
  • [32] Metallurgical Failure Analysis of Drum Arching Tube of a 140 MW Thermal Power Plant
    Mondal, Abhijit
    Roy, H.
    Ghosh, Debashis
    Shukla, A. K.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2014, 14 (05) : 574 - 577
  • [33] Failure Investigation of a Final Super Heater Tube in a 140 MW Thermal Power Plant
    Saha, Atanu
    Roy, H.
    Shukla, A. K.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2015, 15 (02) : 184 - 189
  • [34] Investigation on the Corrosion of the Elbows in the Flue Gas Cooler of a 600 MW Coal-Fired Power Plant
    Pan, Peiyuan
    Zhou, Weijian
    Chen, Heng
    Zhang, Naiqiang
    ACS OMEGA, 2020, 5 (50): : 32551 - 32563
  • [35] Component and process based exergy evaluation of a 600MW coal-fired power plant
    Wu, Lingnan
    Wang, Ligang
    Wang, Yang
    Hu, Xiaoying
    Dong, Changqing
    Yang, Zhiping
    Yang, Yongping
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 2097 - 2100
  • [36] Case Study on Fireside Erosion of Platen Superheater Boiler Tubes of a Coal-Fired Power Plant
    Adnyana, D. N.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (04) : 1578 - 1589
  • [37] Case Study on Fireside Erosion of Platen Superheater Boiler Tubes of a Coal-Fired Power Plant
    D. N. Adnyana
    Journal of Failure Analysis and Prevention, 2022, 22 : 1578 - 1589
  • [38] Evaluation and Assessment of a Superheater-Tube Elbow in a Coal-Based Power Plant Boiler after 10 Years of Operation
    Ramadhan, Faizal
    Aujul Majdi, M.
    Arfi, Abdulazis
    Suwarno, Suwarno
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (03) : 1356 - 1368
  • [39] Evaluation and Assessment of a Superheater-Tube Elbow in a Coal-Based Power Plant Boiler after 10 Years of Operation
    Faizal Ramadhan
    M. Aujul Majdi
    Abdulazis Arfi
    Suwarno Suwarno
    Journal of Failure Analysis and Prevention, 2023, 23 : 1356 - 1368
  • [40] The dynamic creep rupture of a secondary superheater tube in a 43 MW coal-fired boiler by the decarburization and multilayer oxide scale buildup on both sides
    Liu, William