Mechanical behavior and collagen structure of degenerative mitral valve leaflets and a finite element model of primary mitral regurgitation

被引:14
作者
Sadeghinia, Mohammad Javad [1 ]
Aguilera, Hans Martin [1 ]
Urheim, Stig [3 ,4 ]
Persson, Robert Matongo [3 ,4 ]
Ellensen, Vegard Skalstad [3 ]
Haaverstad, Rune [3 ,4 ]
Holzapfel, Gerhard A. [1 ,2 ]
Skallerud, Bjorn [1 ]
Prot, Victorien [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Struct Engn, Trondheim, Norway
[2] Graz Univ Technol, Inst Biomech, Graz, Austria
[3] Haukeland Hosp, Dept Heart Dis, Bergen, Norway
[4] Univ Bergen, Inst Clin Sci, Bergen, Norway
关键词
Mitral valve; Collagen; Tissue modeling; Finite element analysis; Second harmonic generation; Tissue clearing; DISEASE; MORPHOLOGY;
D O I
10.1016/j.actbio.2023.03.029
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Degenerative mitral valve disease is the main cause of primary mitral regurgitation with two phenotypes: fibroelastic deficiency (FED) often with localized myxomatous degeneration and diffuse myxomatous de-generation or Barlow's disease. Myxomatous degeneration disrupts the microstructure of the mitral valve leaflets, particularly the collagen fibers, which affects the mechanical behavior of the leaflets. The present study uses biaxial mechanical tests and second harmonic generation microscopy to examine the mechan-ical behavior of Barlow and FED tissue. Three tissue samples were harvested from a FED patient and one sample is from a Barlow patient. Then we use an appropriate constitutive model by excluding the colla-gen fibers under compression. Finally, we built an FE model based on the echocardiography of patients diagnosed with FED and Barlow and the characterized material model and collagen fiber orientation. The Barlow sample and the FED sample from the most affected segment showed different mechanical behavior and collagen structure compared to the other two FED samples. The FE model showed very good agreement with echocardiography with 2 . 02 & PLUSMN; 1 . 8 mm and 1 . 05 & PLUSMN; 0 . 79 mm point-to-mesh distance errors for Barlow and FED patients, respectively. It has also been shown that the exclusion of collagen fibers under compression provides versatility for the material model; it behaves stiff in the belly region, preventing excessive bulging, while it behaves very softly in the commissures to facilitate folding. Statement of significance This study quantifies for the first time the collagen microstructure and mechanical behavior of degenera-tive mitral valve (DMV) leaflets. These data will then be used for the first disease-specific finite element (FE) model of DMV. While current surgical repair of DMV is based on surgical experience, FE modeling has the potential to support decision-making and make outcomes predictable. We adopt a constitutive model to exclude collagen fiber under compressions, an important consideration when modeling the mi-tral valve, where the leaflets are folded to ensure complete closure. The results of this study provide essential data for understanding the relationship between collagen microstructure and degenerative mi-tral valve mechanics.& COPY; 2023 The Author(s). Published by Elsevier Ltd on behalf of Acta Materialia Inc. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ )
引用
收藏
页码:269 / 281
页数:13
相关论文
共 50 条
[41]   Neochord placement versus triangular resection in mitral valve repair: A finite element model [J].
Morgan, Ashley E. ;
Pantoja, Joe L. ;
Grossi, Eugene A. ;
Ge, Liang ;
Weinsaft, Jonathan W. ;
Ratcliffe, Mark B. .
JOURNAL OF SURGICAL RESEARCH, 2016, 206 (01) :98-105
[42]   Biomechanics of mitral valve leaflets: Second harmonic generation microscopy, biaxial mechanical tests and tissue modeling [J].
Sadeghinia, Mohammad Javad ;
Skallerud, Bjorn ;
Holzapfel, Gerhard A. ;
Prot, Victorien .
ACTA BIOMATERIALIA, 2022, 141 :244-254
[43]   Association of altered collagen content and lysyl oxidase expression in degenerative mitral valve disease [J].
Purushothaman, K-Raman ;
Purushothaman, Meerarani ;
Turnbull, Irene C. ;
Adams, David H. ;
Anyanwu, Anelechi ;
Krishnan, Prakash ;
Kini, Annapoorna ;
Sharma, Samin K. ;
O'Connor, William N. ;
Moreno, Pedro R. .
CARDIOVASCULAR PATHOLOGY, 2017, 29 :11-18
[44]   Finite element analysis of mitral valve annuloplasty in Barlow's disease [J].
Aguilera, Hans Martin ;
Urheim, Stig ;
Persson, Robert Matongo ;
Haaverstad, Rune ;
Skallerud, Bjorn ;
Prot, Victorien .
JOURNAL OF BIOMECHANICS, 2022, 142
[45]   Fluid-structure interaction simulation of pathological mitral valve dynamics in a coupled mitral valve-left ventricle model [J].
Cai, Li ;
Zhao, Tong ;
Wang, Yongheng ;
Luo, Xiaoyu ;
Gao, Hao .
INTELLIGENT MEDICINE, 2023, 3 (02) :104-114
[46]   Elevated Mitral Valve Pressure Gradient Is Predictive of Long-Term Outcome After Percutaneous Edge-to-Edge Mitral Valve Repair in Patients With Degenerative Mitral Regurgitation (MR), But Not in Functional MR [J].
Patzelt, Johannes ;
Zhang, Wenzhong ;
Sauter, Reinhard ;
Mezger, Matthias ;
Nording, Henry ;
Ulrich, Miriam ;
Becker, Annika ;
Patzelt, Tara ;
Rudolph, Volker ;
Eitel, Ingo ;
Saad, Mohammed ;
Bamberg, Fabian ;
Schlensak, Christian ;
Gawaz, Meinrad ;
Boekstegers, Peter ;
Schreieck, Juergen ;
Seizer, Peter ;
Langer, Harald F. .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (13)
[47]   Clinical and Prognostic Impact of a New Left Ventricular Ejection Index in Primary Mitral Regurgitation Because of Mitral Valve Prolapse [J].
Magne, Julien ;
Szymanski, Catherine ;
Fournier, Alexandre ;
Malaquin, Dorothee ;
Avierinos, Jean Francois ;
Tribouilloy, Christophe .
CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (09)
[48]   Mitral Valve Coaptation Reserve Index: A Model to Localize Individual Resistance to Mitral Regurgitation Caused by Annular Dilation [J].
Jainandunsing, Jayant S. ;
Massari, Dario ;
Vos, Jaap Jan ;
Wijdh-den Hamer, Inez J. ;
van den Heuvel, Ad F. M. ;
Mariani, Massimo A. ;
Mahmood, Feroze ;
Bouma, Wobbe ;
Scheeren, Thomas W. L. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (05) :690-697
[49]   Influence of Annular Dynamics and Material Behavior in Finite Element Analysis of Barlow’s Mitral Valve Disease [J].
Hans Martin Aguilera ;
Stig Urheim ;
Bjørn Skallerud ;
Victorien Prot .
Journal of Elasticity, 2021, 145 :163-190
[50]   Influence of Annular Dynamics and Material Behavior in Finite Element Analysis of Barlow's Mitral Valve Disease [J].
Aguilera, Hans Martin ;
Urheim, Stig ;
Skallerud, Bjorn ;
Prot, Victorien .
JOURNAL OF ELASTICITY, 2021, 145 (1-2) :163-190