Improved accuracy of the biodistribution and internal radiation dosimetry of 13N-ammonia using a total-body PET/CT scanner

被引:5
作者
Yu, Xiaofeng [1 ]
Sun, Hongyan [2 ]
Xu, Lian [1 ]
Han, Yuan [1 ]
Wang, Cheng [1 ]
Li, Lianghua [1 ]
Ng, YeeLing [2 ]
Shi, Fuxiao [2 ]
Qiu, Ju [1 ]
Huang, Gang [1 ]
Zhou, Yun [2 ]
Chen, Yumei [1 ,3 ]
Liu, Jianjun [1 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Renji Hosp, Sch Med, Dept Nucl Med, Shanghai, Peoples R China
[2] United Imaging Healthcare, Cent Res Inst, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Renji Hosp, Sch Med, Dept Nucl Med, 160 Pujian Rd, Shanghai 200127, Peoples R China
基金
中国国家自然科学基金;
关键词
13N-ammonia; biodistribution; internal radiation dose; total-body PET; CT; uEXPLORER;
D O I
10.1002/mp.16450
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundConventional short-axis PET typically utilizes multi-bed multi-pass acquisition to produce quantitative whole-body dynamic images and cannot record all the uptake information simultaneously, resulting in errors when fitting the time-activity curves (TACs) and calculating radiation doses. PurposeThe aim of this study is to evaluate the N-13-ammonia biodistribution and the internal radiation doses using a 194 cm long total-body PET/CT scanner (uEXPLORER), and make a comparison with the previous short-axis PET results. MethodsTen subjects (age 40-74 years) received N-13-NH3 injection (418.1-670.81 MBq) and were under a dynamic scan for about 60 min with using a 3-dimensional whole-body protocol. ROIs were drawn visually on 11 major organs (brain, thyroid, gallbladder, heart wall, kidneys, liver, pancreas, spleen, lungs, bone marrow, and urinary bladder content) for each subject. TACs were generated using Pmod and the absorbed radiation doses were calculated using Olinda 2.2. To compare with the conventional PET/CT, five points were sampled on uEXPLORER's TACs to mimic the result of a short-axis PET/CT (15 cm axial FOV, consisted of 9 or 10 bed positions). Then the TACs were obtained using the multi-exponential fitting method, and the residence time and radiation dose were also calculated and compared with uEXPLORER. ResultsThe highest absorbed organ doses were the pancreas, thyroid, spleen, heart wall, and kidneys for the male. For the female, the first five highest absorbed organ dose coefficients were the pancreas, heart wall, spleen, lungs, and kidneys. The lowest absorbed dose was found in red marrow both for male and female. The simulated short-axis PET can fit TACs well for the gradually-changed uptake organs but typically underestimated for the rapid-uptake organs during the first-10 min, resulting in errors in the calculated radiation dose. ConclusionuEXPLORER PET/CT can measure N-13-ammonia's TACs simultaneously in all organs of the whole body, which can provide more accurate biodistribution and radiation dose estimation compared with the conventional short-axis scanners.
引用
收藏
页码:5865 / 5874
页数:10
相关论文
共 25 条
  • [1] First Human Imaging Studies with the EXPLORER Total-Body PET Scanner
    Badawi, Ramsey D.
    Shi, Hongcheng
    Hu, Pengcheng
    Chen, Shuguang
    Xu, Tianyi
    Price, Patricia M.
    Ding, Yu
    Spencer, Benjamin A.
    Nardo, Lorenzo
    Liu, Weiping
    Bao, Jun
    Jones, Terry
    Li, Hongdi
    Cherry, Simon R.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (03) : 299 - 303
  • [2] Berger M. J., 1971, Journal of Nuclear Medicine, V12, P5
  • [3] Bolch WE., 1991, J NUCL MED, V40, p11s
  • [4] MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry-Standardization of Nomenclature
    Bolch, Wesley E.
    Eckerman, Keith F.
    Sgouros, George
    Thomas, Stephen R.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (03) : 477 - 484
  • [5] Performance characteristics of the digital uMI550 PET/CT system according to the NEMA NU2-2018 standard
    Chen, Shuguang
    Hu, Pengcheng
    Gu, Yushen
    Yu, Haojun
    Shi, Hongcheng
    [J]. EJNMMI PHYSICS, 2020, 7 (01)
  • [6] Cherry SR, 2006, J NUCL MED, V47, P1735
  • [7] Diagnostic accuracy of 13N-ammonia PET, 11C-methionine PET and 18F-fluorodeoxyglucose PET: a comparative study in patients with suspected cerebral glioma
    He, Qiao
    Zhang, Linqi
    Zhang, Bing
    Shi, Xinchong
    Yi, Chang
    Zhang, Xiangsong
    [J]. BMC CANCER, 2019, 19 (1)
  • [8] Internal dosimetry in F-18 FDG PET examinations based on long-time-measured organ activities using total-body PET/CT: does it make any difference from a short-time measurement?
    Hu, Pengcheng
    Lin, Xin
    Zhuo, Weihai
    Tan, Hui
    Xie, Tianwu
    Liu, Guobing
    Chen, Shuguang
    Chen, Xin
    Yu, Haojun
    Zhang, Yiqiu
    Shi, Hongcheng
    Liu, Haikuan
    [J]. EJNMMI PHYSICS, 2021, 8 (01)
  • [9] Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET
    Karakatsanis, Nicolas A.
    Zhou, Yun
    Lodge, Martin A.
    Casey, Michael E.
    Wahl, Richard L.
    Zaidi, Habib
    Rahmim, Arman
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (22) : 8643 - 8673
  • [10] Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application
    Karakatsanis, Nicolas A.
    Lodge, Martin A.
    Tahari, Abdel K.
    Zhou, Y.
    Wahl, Richard L.
    Rahmim, Arman
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20) : 7391 - 7418