A Prospective Cohort Study of Radiation Exposure to a Spine Surgeon's Exposed Body Parts During Utilization of Intraoperative Radiation-based Imaging

被引:1
作者
Chauhan, Daksh [1 ]
Ahmad, Hasan S. [1 ]
Singh, Shikha [1 ]
Albayar, Ahmed [1 ]
Patel, Arjun [1 ]
Welch, William C. [1 ]
Yoon, Jang W. [1 ,2 ]
机构
[1] Univ Penn, Perelman Sch Med, Dept Neurosurg, Philadelphia, PA USA
[2] Penn Hosp, Dept Neurosurg, 800 Spruce St, Philadelphia, PA 19107 USA
来源
CLINICAL SPINE SURGERY | 2023年 / 36卷 / 03期
关键词
radiation monitoring; dosimetry; spine surgery; fluoroscopy; navigation; INTERVENTIONAL RADIOLOGY; NAVIGATION; PATIENT; SHIELD; TRENDS; CANCER; RISK;
D O I
10.1097/BSD.0000000000001450
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design:Prospective cohort study. Summary of Background Data:C-arm fluoroscopy and O-arm navigation are vital tools in modern spine surgeries, but their repeated usage can endanger spine surgeons. Although a surgeon's chest and abdomen are protected by lead aprons, the eyes and extremities generally receive less protection. Objective:In this study, we compare differences in intraoperative radiation exposure across the protected and unprotected regions of a surgeon's body. Methods:Sixty-five consecutive spine surgeries were performed by a single spine-focused neurosurgeon over 9 months. Radiation exposure to the primary surgeon was measured through dosimeters worn over the lead apron, under the lead apron, on surgical loupes, and as a ring on the dominant hand. Differences were assessed with rigorous statistical testing and radiation exposure per surgical case was extrapolated. Results:During the study, the measured radiation exposure over the apron, 176 mrem, was significantly greater than that under the apron, 8 mrem (P = 0.0020), demonstrating a shielding protective effect. The surgeon's dominant hand was exposed to 329 mrem whereas the eyes were exposed to 152.5 mrem of radiation. Compared with the surgeon's protected abdominal area, the hands (P = 0.0002) and eyes (P = 0.0002) received significantly greater exposure. Calculated exposure per case was 2.8 mrem for the eyes and 5.1 mrem for the hands. It was determined that a spine-focused neurosurgeon operating 400 cases annually will incur a radiation exposure of 60,750 mrem to the hands and 33,900 mrem to the eyes over a 30-year career. Conclusions:Our study found that spine surgeons encounter significantly more radiation exposure to the eyes and the extremities compared with protected body regions. Lifetime exposure exceeds the annual limits set by the International Commission on Radiologic Protection for the extremities (50,000 mrem/y) and the eyes (15,000 mrem/y), calling for increased awareness about the dangerous levels of radiation exposure that a spine surgeon incurs over one's career.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 36 条
[1]  
Akram S.M., 2022, STATPEARLS
[2]  
[Anonymous], 2014, Strategies for the Management of Localized Prostate Cancer: A Guide for Radiation Oncologists, P1
[3]   Effect of C-Arm Year Model on Radiation Scatter [J].
Bakr, Omar ;
Morshed, Saam ;
Marmor, Meir .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (01)
[4]   National Trends in Ambulatory Surgery for Intervertebral Disc Disorders and Spinal Stenosis: A 12-Year Analysis of the National Surveys of Ambulatory Surgery [J].
Best, Matthew J. ;
Buller, Leonard T. ;
Eismont, Frank J. .
SPINE, 2015, 40 (21) :1703-1711
[5]   Radiation Exposure of Patient and Operating Room Personnel by Fluoroscopy and Navigation during Spinal Surgery [J].
Bratschitsch, G. ;
Leitner, L. ;
Stuecklschweiger, G. ;
Guss, H. ;
Sadoghi, P. ;
Puchwein, P. ;
Leithner, A. ;
Radl, R. .
SCIENTIFIC REPORTS, 2019, 9 (1)
[6]  
Burns S, 2013, J BONE JOINT SURG AM, V95A, P1307, DOI [10.2106/JBJS.L.00893, 10.2106/JBJS.L00893]
[7]  
CDC, 2022, Centers for Disease Control and Prevention WWW Document
[8]   Risk of cataract after exposure to low doses of ionizing radiation: A 20-year prospective cohort study among US radiologic technologists [J].
Chodick, Gabriel ;
Bekiroglu, Nural ;
Hauptmann, Michael ;
Alexander, Bruce H. ;
Freedman, D. Michal ;
Doody, Michele Morin ;
Cheung, Li C. ;
Simon, Steven L. ;
Weinstock, Robert M. ;
Bouville, Andre ;
Sigurdson, Alice J. .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2008, 168 (06) :620-631
[9]   Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study [J].
Chung, Kwang Hyun ;
Park, Young Sook ;
Ahn, Sang Bong ;
Son, Byoung Kwan .
BMJ OPEN, 2019, 9 (03)
[10]   Unprotected Operator Eye Lens Doses in Oncologic Interventional Radiology Are Clinically Significant: Estimation from Patient Kerma-area-product Data [J].
Dauer, Lawrence T. ;
Thornton, Raymond H. ;
Solomon, Stephen B. ;
St Germain, Jean .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (12) :1859-1861