Very high-power and short-duration radiofrequency ablation for atrial fibrillation in a Latin American low-volume private center

被引:0
作者
Keegan, Roberto [1 ]
Garmendia, Francisco [1 ]
Gregorietti, Franco [1 ]
Urruti, Ricardo [1 ]
Onetto, Leonardo [1 ]
机构
[1] Hosp Privado Sur, Electrophysiol Serv, Bahia Blanca, Buenos Aires, Argentina
关键词
Atrial fibrillation; Catheter ablation; Radiofrequency; High-power short-duration; Low-volume center; PULMONARY VEIN ISOLATION; CATHETER ABLATION; MULTICENTER;
D O I
10.1007/s10840-024-01756-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundC enter volume and operator experience/training are important factors impacting outcomes in AFib CA. Setting for RF delivery (power, duration, and contact force) associated with better outcomes remains to be determined. Methods This is an observational, longitudinal, and retrospective study. All consecutive procedures performed between December 12, 2013, and March 9, 2023, in a low-volume private center in Latin America were analyzed. Procedure characteristics and outcomes were compared between STD and vHPSD. Results Two hundred ten procedures were performed on 194 patients. Median annual number of procedures was 19 (7-29). Median age was 62 (52-68), and majority were male (71%). Median procedure duration was 155 (125-195) min, mean fluoroscopy time 32.8 +/- 15 min and mean fluoroscopy dose 373.5 +/- 208.9 mGray. Median follow-up was 27 months, significantly longer in STD compared with vHPSD group (43 [31-68] vs. 13 [8-19], respectively; P <= 0.001). The recurrence rate was 33.2% and major complications 8.6%. Compared with STD, vHPSD resulted in a significantly shorter procedure duration (125 vs. 180 min, P <= 0.001), shorter fluoroscopy time (22.7 +/- 9.5 vs. 39.2 +/- 14.3 min, P <= 0.001), and lower fluoroscopy dose (283.8 +/- 161.1 vs. 438.3 +/- 216.1 mGray, P <= 0.001). No long-term recurrence difference was observed when the follow-up periods were comparable. No difference in complication rate was observed (8.5% vs. 8.6%, P=0.988). Conclusions Outcomes in AFib CA in a Latin American low-volume private center can be considered acceptable, with efficacy and safety similar to those reported in the literature. Compared with STD ablation, vHPSD showed higher efficiency with similar efficacy and safety.
引用
收藏
页码:1399 / 1406
页数:8
相关论文
共 26 条
[1]   High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability [J].
Barkagan, Michael ;
Contreras-Valdes, Fernando M. ;
Leshem, Eran ;
Buxton, Alfred E. ;
Nakagawa, Hiroshi ;
Anter, Elad .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (09) :1287-1296
[2]   Five seconds of 50-60 W radio frequency atrial ablations were transmural and safe: an in vitro mechanistic assessment and force-controlled in vivo validation [J].
Bhaskaran, Abhishek ;
Chik, William ;
Pouliopoulos, Jim ;
Nalliah, Chrishan ;
Qian, Pierre ;
Barry, Tony ;
Nadri, Fazlur ;
Samanta, Rahul ;
Tran, Ying ;
Thomas, Stuart ;
Kovoor, Pramesh ;
Thiagalingam, Aravinda .
EUROPACE, 2017, 19 (05) :874-880
[3]   High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics [J].
Bourier, Felix ;
Duchateau, Josselin ;
Vlachos, Konstantinos ;
Lam, Anna ;
Martin, Claire A. ;
Takigawa, Masateru ;
Kitamura, Takeshi ;
Frontera, Antonio ;
Cheniti, Ghassen ;
Pambrun, Thomas ;
Klotz, Nicolas ;
Denis, Arnaud ;
Derval, Nicolas ;
Cochet, Hubert ;
Sacher, Frederic ;
Hocini, Meleze ;
Haissaguerre, Michel ;
Jais, Pierre .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) :1570-1575
[4]  
Calkins H, 2018, EUROPACE, V20, pE1, DOI [10.1093/europace/eux274, 10.1093/europace/eux275, 10.1016/j.hrthm.2017.05.012]
[5]  
Calkins H, 2017, HEART RHYTHM, V14, pE445, DOI [10.1016/j.hrthm.2017.05.012, 10.1093/europace/eux275, 10.1016/j.hrthm.2017.07.009]
[6]   Multicenter prospective comparison of conventional and high-power short duration radiofrequency application for pulmonary vein isolation: the high-power short-duration radiofrequency application for faster and safer pulmonary vein ablation (POWER FAST III) trial [J].
Castrejon-Castrejon, Sergio ;
Cossiani, Marcel Martinez ;
Jauregui-Abularach, Miguel ;
Sola, Nuria Basterra ;
Criado, Jose Luis Ibanez ;
Asensi, Joaquin Osca ;
Luque, Ivo Roca ;
Mitjans, Angel Moya ;
Dorador, Aurelio Quesada ;
Olivares, Victor Manuel Hidalgo ;
Castellano, Nicasio Perez ;
Gomez, Juan Manuel Fernandez ;
Macias-Ruiz, Maria Rosa ;
Villanueva, Bruno Bochard ;
Bada, Nerea Gonzalo ;
Prieto, Andres Fernandez ;
Lopez, Leonardo Elias Guido ;
Maldonado, Maria Eugenia Martinez ;
Merino, Daniel ;
Cervantes, Carlos Escobar ;
Merino, Jose Luis ;
OWER FAST III trial invest .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (08) :1889-1899
[7]   Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study [J].
Castrejon-Castrejon, Sergio ;
Martinez Cossiani, Marcel ;
Ortega Molina, Marta ;
Escobar, Carlos ;
Froilan Torres, Consuelo ;
Gonzalo Bada, Nerea ;
Diaz de la Torre, Marta ;
Suarez Parga, Jose Manuel ;
Lopez Sendon, Jose Luis ;
Luis Merino, Jose .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (01) :57-65
[8]   Inpatient hospital procedural volume and outcomes following catheter ablation of atrial fibrillation [J].
Cheung, Jim W. ;
Yeo, Ilhwan ;
Cheng, Edward P. ;
Ip, James E. ;
Thomas, George ;
Liu, Christopher F. ;
Markowitz, Steven M. ;
Kim, Luke K. ;
Lerman, Bruce B. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) :1908-1919
[9]   THE BIOPHYSICS OF RADIOFREQUENCY CATHETER ABLATION IN THE HEART - THE IMPORTANCE OF TEMPERATURE MONITORING [J].
HAINES, DE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03) :586-591
[10]  
Hosseini Seyed Mohammadreza, 2017, JACC Clin Electrophysiol, V3, P1240, DOI 10.1016/j.jacep.2017.05.005