Intracardiac echocardiography-guided pulsed-field ablation for successful ablation of atrial fibrillation: a propensity-matched analysis from a large nationwide multicenter experience

被引:17
作者
Dello Russo, Antonio [1 ,2 ,3 ]
Tondo, Claudio [4 ]
Schillaci, Vincenzo [5 ]
Casella, Michela [1 ,2 ,6 ]
Iacopino, Saverio [7 ]
Bianchi, Stefano [8 ]
Fassini, Gaetano [4 ]
Rossillo, Antonio [9 ]
Compagnucci, Paolo [1 ,2 ,3 ]
Schiavone, Marco [4 ]
Salito, Armando [5 ]
Maggio, Ruggero [10 ]
Cipolletta, Laura [1 ,2 ]
Themistoclakis, Sakis [11 ]
Pandozi, Claudio [12 ]
Filannino, Pasquale [7 ]
Rossi, Pietro [8 ]
Bonanno, Carlo [9 ]
Parisi, Quintino [1 ,2 ]
Malacrida, Maurizio [13 ]
Solimene, Francesco [3 ,5 ]
机构
[1] Univ Hosp Osped Riuniti Umberto I Lancisi Salesi, Dept Cardiol, Via Conca 71, I-60126 Ancona, Italy
[2] Univ Hosp Osped Riuniti Umberto I Lancisi Salesi, Arrhythmol Clin, Via Conca 71, I-60126 Ancona, Italy
[3] Marche Polytech Univ, Dept Biomed Sci & Publ Hlth, Ancona, Italy
[4] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[5] Montevergine Clin, Mercogliano, AV, Italy
[6] Marche Polytech Univ, Dept Clin Special & Dent Sci, Ancona, Italy
[7] Maria Cecilia Hosp, Cotignola, RA, Italy
[8] Fatebenefratelli Isola Tiberina Gemelli Isola Hosp, Rome, Italy
[9] San Bortolo Hosp, Vicenza, Italy
[10] Infermi Hosp, Rivoli, TO, Italy
[11] DellAngelo Hosp, Venice, VE, Italy
[12] San Filippo Neri Hosp, Rome, Italy
[13] Boston Sci, Milan, Italy
关键词
Atrial fibrillation; Electroporation; Pulsed-field ablation; Intracardiac echocardiography;
D O I
10.1007/s10840-023-01699-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Intracardiac echocardiography (ICE) is increasingly employed in atrial fibrillation (AF) ablation procedures, with the potential to enhance procedural efficacy. Nevertheless, there is currently a lack of evidence assessing the impact of ICE on the efficiency, effectiveness, and safety outcomes in the context of novel pulsed-field ablation (PFA) for AF.Purpose: We aimed to assess whether the use of ICE could improve procedural parameters in a large population undergoing AF ablation with FARAPULSE (TM) catheter.Methods: Consecutive patients who had undergone PFA of AF from nine Italian centers were included. In procedures where the ICE catheter was employed for guidance (ICE-guided group), it was used to maneuver the PFA catheter within the left atrium to achieve optimal contact with atrial structures.Results: We analyzed 556 patients: 357 (66%) with paroxysmal AF, 499 (89.7%) de novo PVI. ICE-guided procedures (n = 138) were propensity matched with patients with a standard approach (n = 138), and their outcomes were compared. During ICE-guided procedures, no improvement in procedural metrics was recorded (ICE vs Standard, 23 +/- 6 min vs 18.5 +/- 9 min for time to PVI, p < 0.0001; 38.8 +/- 7 vs 32.5 +/- 5 number of PFA deliveries to achieve PVI, p < 0.0001; 68.8 +/- 19 min vs 71.8 +/- 29 min for primary operator time, p = 0.5301; 16.1 +/- 8 min vs 18.2 +/- 10 min for fluoroscopy time, p = 0.5476) except for support time (76.8 +/- 26 min vs 91.4 +/- 37 min, p = 0.0046). No major procedure-related adverse events were reported.Conclusion: Our findings confirmed that PFA could be consistently performed in a rapid, safe, and efficacious manner. The use of ICE to guide PFA was not associated with an improvement in procedural metrics.
引用
收藏
页码:1257 / 1266
页数:10
相关论文
共 21 条
[1]   Safety and efficacy of intracardiac echocardiography-guided zero-fluoroscopic cryoballoon ablation for atrial fibrillation: a prospective randomized controlled trial [J].
Ahn, Jinhee ;
Shin, Dong Geum ;
Han, Sang-Jin ;
Lim, Hong Euy .
EUROPACE, 2023, 25 (05)
[2]   Contemporary management of patients undergoing atrial fibrillation ablation: in-hospital and 1-year follow-up findings from the ESC-EHRA atrial fibrillation ablation long-term registry [J].
Arbelo, Elena ;
Brugada, Josep ;
Blomstrom-Lundqvist, Carina ;
Laroche, Cecile ;
Kautzner, Josef ;
Pokushalov, Evgeny ;
Raatikainen, Pekka ;
Efremidis, Michael ;
Hindricks, Gerhard ;
Barrera, Alberto ;
Maggioni, Aldo ;
Tavazzi, Luigi ;
Dagres, Nikolaos .
EUROPEAN HEART JOURNAL, 2017, 38 (17) :1303-1316
[3]   New energy sources and technologies for atrial fibrillation catheter ablation [J].
Boersma, Lucas .
EUROPACE, 2022, 24 (SUPPL 2) :44-51
[4]  
Dello Russo Antonio, 2013, J Atr Fibrillation, V5, P786, DOI 10.4022/jafib.786
[5]   Usefulness of intracardiac echocardiography during pulmonary vein isolation with the novel multipolar irrigated ablation catheter (nMARQTM) [J].
Dello Russo, Antonio ;
Fassini, Gaetano ;
Casella, Michela ;
Di Monaco, Antonio ;
Riva, Stefania ;
Romano, Valentina ;
Moltrasio, Massimo ;
Tundo, Fabrizio ;
De Martino, Giuseppe ;
Majocchi, Benedetta ;
Marino, Vittoria ;
Russo, Eleonora ;
Pizzamiglio, Francesca ;
Del Giorno, Giuseppe ;
Pelargonio, Gemma ;
Di Biase, Luigi ;
Natale, Andrea ;
Tondo, Claudio .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 44 (01) :39-45
[6]   Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF) [J].
Ekanem, Emmanuel ;
Reddy, Vivek Y. ;
Schmidt, Boris ;
Reichlin, Tobias ;
Neven, Kars ;
Metzner, Andreas ;
Hansen, Jim ;
Blaauw, Yuri ;
Maury, Philippe ;
Arentz, Thomas ;
Sommer, Philipp ;
Anic, Ante ;
Anselme, Frederic ;
Boveda, Serge ;
Deneke, Tom ;
Willems, Stephan ;
van der Voort, Pepijn ;
Tilz, Roland ;
Funasako, Moritoshi ;
Scherr, Daniel ;
Wakili, Reza ;
Steven, Daniel ;
Kautzner, Josef ;
Vijgen, Johan ;
Jais, Pierre ;
Petru, Jan ;
Chun, Julian ;
Roten, Laurent ;
Fueting, Anna ;
Rillig, Andreas ;
Mulder, Bart A. ;
Johannessen, Arne ;
Rollin, Anne ;
Lehrmann, Heiko ;
Sohns, Christian ;
Jurisic, Zrinka ;
Savoure, Arnaud ;
Combes, Stephanes ;
Nentwich, Karin ;
Gunawardene, Melanie ;
Ouss, Alexandre ;
Kirstein, Bettina ;
Manninger, Martin ;
Bohnen, Jan-Eric ;
Sultan, Arian ;
Peichl, Petr ;
Koopman, Pieter ;
Derval, Nicolas ;
Turagam, Mohit K. ;
Neuzil, Petr .
EUROPACE, 2022, :1256-1266
[7]   First experience with pulsed field ablation as routine treatment for paroxysmal atrial fibrillation [J].
Fueting, Anna ;
Reinsch, Nico ;
Hoewel, Dennis ;
Brokkaar, Lenny ;
Rahe, Gilbert ;
Neven, Kars .
EUROPACE, 2022, :1084-1092
[8]   The use of intracardiac echocardiography catheters in endocardial ablation of cardiac arrhythmia: Meta-analysis of efficiency, effectiveness, and safety outcomes [J].
Goya, Masahiko ;
Frame, Diana ;
Gache, Larry ;
Ichishima, Yoko ;
Tayar, Daiane Oliveira ;
Goldstein, Laura ;
Lee, Stephanie Hsiao Yu .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (03) :664-673
[9]   Pulsed-field ablation combined with ultrahigh-density mapping in patients undergoing catheter ablation for atrial fibrillation: Practical and electrophysiological considerations [J].
Gunawardene, Melanie A. ;
Schaeffer, Benjamin N. ;
Jularic, Mario ;
Eickholt, Christian ;
Maurer, Tilman ;
Akbulak, Ruken O. ;
Flindt, Max ;
Anwar, Omar ;
Pape, Ulrich F. ;
Maasberg, Sebastian ;
Gessler, Nele ;
Hartmann, Jens ;
Willems, Stephan .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (03) :345-356
[10]  
Hindricks G, 2021, EUR HEART J, V42, P546, DOI [10.1093/eurheartj/ehaa945, 10.1093/eurheartj/ehaa612]