Rheological engineering of perovskite suspension toward high-resolution X-ray flat-panel detector

被引:36
|
作者
Song, Zihao [1 ,2 ]
Du, Xinyuan [1 ,2 ]
He, Xin [1 ,2 ]
Wang, Hanqi [1 ,2 ]
Liu, Zhiqiang [1 ,2 ]
Wu, Haodi [1 ,2 ]
Luo, Hongde [3 ]
Jin, Libo [3 ]
Xu, Ling [1 ,2 ]
Zheng, Zhiping [1 ,2 ]
Niu, Guangda [1 ,2 ,4 ]
Tang, Jiang [1 ,2 ,4 ]
机构
[1] Huazhong Univ Sci & Technol HUST, Wuhan Natl Lab Optoelect WNLO, Wuhan 430074, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol HUST, Sch Opt & Elect Informat, Wuhan 430074, Peoples R China
[3] iRay Technol Co Ltd, Shanghai 201206, Peoples R China
[4] Huazhong Univ Sci & Technol, Ezhou Ind Technol Res Inst, Ezhou 436060, Peoples R China
基金
中国国家自然科学基金;
关键词
AMORPHOUS SELENIUM; LARGE-AREA; FABRICATION; UNIFORMITY; QUALITY; IODIDE;
D O I
10.1038/s41467-023-42616-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Solution-processed polycrystalline perovskite film is promising for the next generation X-ray imaging. However, the spatial resolution of current perovskite X-ray panel detectors is far lower than the theoretical limit. Herein we find that the pixel level non-uniformity, also known as fixed pattern noise, is the chief culprit affecting the signal-to-noise ratio and reducing the resolution of perovskite detectors. We report a synergistic strategy of rheological engineering the perovskite suspensions to achieve X-ray flat panel detectors with pixel-level high uniformity and near-to-limit spatial resolution. Our approach includes the addition of methylammonium iodide and polyacrylonitrile to the perovskite suspension, to synergistically enhance the flowability and particle stability of the oversaturated solution. The obtained suspension perfectly suits for the blade-coating process, avoiding the uneven distribution of solutes and particles within perovskite films. The assembled perovskite panel detector exhibits greatly improved fixed pattern noise value (1.39%), high sensitivity (2.24 x 104 mu C Gyair-1 cm-2), low detection limit (28.57 nGyair center dot s-1) as well as good working stability, close to the performance of single crystal detectors. Moreover, the detector achieves a near-to-limit resolution of 0.51 lp/pix. The film uniformity is essential to the fixed pattern noise (FPN) and resolution of X-ray detectors. Here the authors demonstrate the rheological engineering of the perovskite suspension to achieve low FPN of 1.39% and high resolution of 0.51 lp/pix.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications
    Hata, Akinori
    Yamada, Yoshitake
    Tanaka, Rie
    Nishino, Mizuki
    Hida, Tomoyuki
    Hino, Takuya
    Ueyama, Masako
    Yanagawa, Masahiro
    Kamitani, Takeshi
    Kurosaki, Atsuko
    Sanada, Shigeru
    Jinzaki, Masahiro
    Ishigami, Kousei
    Tomiyama, Noriyuki
    Honda, Hiroshi
    Kudoh, Shoji
    Hatabu, Hiroto
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (04) : 634 - 651
  • [22] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Choi, JY
    Park, JK
    Lee, DG
    Kang, SS
    Nam, SH
    NEW APPLICATIONS FOR WIDE-BANDGAP SEMICONDUCTORS, 2003, 764 : 265 - 270
  • [23] Prospects for x-ray exposure reduction using digital radiography with a flat-panel detector
    Okusako, K
    Hatagawa, M
    Kishimoto, K
    Tanaka, K
    Kudo, H
    Yamada, R
    RADIOLOGY, 2001, 221 : 158 - 158
  • [24] Measurement of the MTF of a flat panel detector in variable resolution x-ray detection
    Zhang, S.
    DiBianca, F.
    MEDICAL PHYSICS, 2007, 34 (06) : 2620 - 2620
  • [25] A-Si TFT off-current analysis for flat-panel x-ray detector
    Kinno, Akira
    Ikeda, Mitsushi
    Atsuta, Masaki
    Uchikoga, Shuichi
    IDW/AD '05: PROCEEDINGS OF THE 12TH INTERNATIONAL DISPLAY WORKSHOPS IN CONJUNCTION WITH ASIA DISPLAY 2005, VOLS 1 AND 2, 2005, : 247 - 250
  • [26] Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging
    Tanaka R.
    Radiological Physics and Technology, 2016, 9 (2) : 139 - 153
  • [27] Experimental evaluation of a novel CdZnTe flat-panel X-ray detector for digital radiography and fluoroscopy
    Tokuda, S
    Adachi, S
    Sato, T
    Yoshimuta, T
    Nagata, H
    Uehara, K
    Izumi, Y
    Teranuma, O
    Yamada, S
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 140 - 147
  • [28] X-ray flat-panel detector geometry correction to improve dimensional computed tomography measurements
    Luethi, Melina
    Bircher, Benjamin A.
    Meli, Felix
    Kueng, Alain
    Thalmann, Rudolf
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (03)
  • [29] The use of a flat-panel detector for seven-beam x-ray coherent scatter imaging
    Foran, Kelly A.
    Johns, Paul C.
    MEDICAL PHYSICS, 2017, 44 (08) : 4377 - 4377
  • [30] Achieving high-resolution in flat-panel imagers for digital radiography
    Rahn, JT
    Lemmi, F
    Lu, JP
    Mei, P
    Street, RA
    Ready, SE
    Ho, J
    Apte, RB
    van Schuylenbergh, K
    Lau, R
    Weisfield, RL
    Lujan, R
    Boyce, J
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 136 - 145