Corrosion monitoring of reinforced concrete structures: The DGZfP specification B12 Collaboration

被引:1
作者
Ebell, Gino [1 ]
Mayer, Till Felix [2 ]
Harnisch, Jorg [3 ]
Dauberschmidt, Christoph [4 ]
机构
[1] Bundesanstalt Materialforschung & Prufung BAM, D-12205 Berlin, Germany
[2] Ingenieurburo Schiessl Gehlen Sodeikat GmbH, Munich, Germany
[3] FH Munster Univ Appl Sci, Munster, Germany
[4] Munich Univ Appl Sci, Munich, Germany
来源
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION | 2024年 / 75卷 / 02期
关键词
corrosion; corrosion monitoring; durability; nondestructive testing; ELECTROCHEMICAL TECHNIQUES;
D O I
10.1002/maco.202313934
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Corrosion monitoring of reinforced or prestressed concrete structures has become increasingly important in recent years. Areas of application include components that are no longer accessible after completion or where potential field measurements cannot be carried out due to existing coatings. Corrosion monitoring can also be used to monitor the progress of corrosion in corroding systems, e.g. to prove the success of repair measures according to repair principle 8 in accordance with EN 1504-9 or repair method 8.3 in accordance with the DIBt repair guideline. It also could be used to prove the functionality of cathodic corrosion protection systems in accordance with ISO 12696. Despite the increasing importance of corrosion monitoring, no guidelines or recommendations existed until 2018. This gap was closed by the English version of specification B12, "Corrosion Monitoring of Reinforced and Prestressed Concrete Structures," of the German Society for Non-Destructive Testing, which was published in 2021. This article introduces specification B12 by explaining the basic measurement principles and illustrating the potential of corrosion monitoring in new and existing buildings.
引用
收藏
页码:188 / 196
页数:9
相关论文
共 19 条
[1]  
[Anonymous], 2022, 12969 ISO
[2]  
[Anonymous], 2008, Products and Systems for the Protection and Repair of Concrete StructuresDefinitions, Requirements, Quality Control and Evaluation of ConformityPart 9: General Principles for the Use of Products and Systems
[3]  
[Anonymous], 2022, C876C87622 ASTM
[4]  
Deutsches Institut f?r Bautechnik,, 2022, TECHN REG INST BET 1
[5]   Half-cell potential measurements - Potential mapping on reinforced concrete structures [J].
Elsener, B ;
Andrade, C ;
Gulikers, J ;
Polder, R ;
Raupach, M .
MATERIALS AND STRUCTURES, 2003, 36 (261) :461-471
[6]  
German Committee for Reinforced Concrete,, 2001, GUID PROT REP REINF
[7]  
German Society for Non-destructive Testing (DGZfP),, 2014, B03 DGZFP
[8]  
German Society for Non-destructive Testing (DGZfP),, 2021, B12 DGZFP
[9]  
Hiemer F., 2018, MONITORING REINFORCE, V35
[10]  
Kapteina G., 2014, CONCR AUST, V40, P42