Simplified Liquid Chromatography-Mass Spectrometry Methods for Gestagen Analysis in Animal Fat and Liver

被引:1
|
作者
Purves, Randy W. [1 ,2 ]
West, Michelle [1 ]
Vaghela, Ratnadipsinh [1 ]
Kinar, Jana [1 ]
Patel, Yash [1 ]
Belford, Michael W. [3 ]
Shurmer, Bryn O. [1 ]
机构
[1] Canadian Food Inspect Agcy, Ctr Vet Drug Residues, Saskatoon, SK S7N 2R3, Canada
[2] Univ Saskatchewan, Coll Pharm & Nutr, Saskatoon, SK S7N 5E5, Canada
[3] Thermo Fisher Sci, San Jose, CA 95134 USA
关键词
MRL; melengestrol acetate; MGA; massspectrometry; LC-MS; food safety; progestogens; DIFFERENTIAL MOBILITY SPECTROMETRY; KIDNEY FAT; MELENGESTROL ACETATE; ANABOLIC-STEROIDS; FAIMS; SEPARATION; QUANTITATION; SENSITIVITY;
D O I
10.1021/acs.jafc.3c01200
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Gestagens, a classof veterinary drugs also called progestogens,are synthetic hormones used to increase feed efficiency and rate ofgain in heifers. The Canadian Food Inspection Agency analyzes progestogensmelengestrol acetate (MGA), megestrol acetate, and chlormadinone acetateusing liquid chromatography-mass spectrometry (LC-MS).Our conventional gestagen method for kidney fat has many time-consumingsteps, including solid-phase extraction. A sample preparation procedurehaving fewer clean-up steps was developed for routine diagnostic analysisof kidney fat and provided similar results faster, and at lower cost.A confirmatory liver method for gestagens, developed using salt-assistedextraction, employed minimal clean-up steps that resulted in highchemical background at the desired lower limit of quantification (LLOQ).Differential ion mobility spectrometry, specifically high-field asymmetricwaveform ion mobility spectrometry (FAIMS), was used to filter chemicalbackground in the gas phase. The effect of the ionization probe positionon FAIMS parameters, including sensitivity, is described. With LC-FAIMS-MS,chemical background for each gestagen was virtually eliminated, resultingin a quantitative liver method having the desired 0.6 ng/g LLOQ andestimated limits of detection (LODs) up to 140 times lower than LC-MS.Incurred MGA samples, analyzed using kidney fat and liver methodsfrom the same animal, show levels within the quantitative ranges ofboth methods.
引用
收藏
页码:9877 / 9885
页数:9
相关论文
共 50 条
  • [1] Confirmatory method for the determination of various acetylgestagens in animal kidney fat using liquid chromatography-tandem mass spectrometry
    Malone, Edward
    Dowling, Geraldine
    Elliott, Chris
    Kennedy, Glenn
    Regan, Liam
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (05): : 672 - 682
  • [2] Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids
    Ahonen, Linda
    Keski-Rahkonen, Pekka
    Saarelainen, Taija
    Paviala, Jenni
    Ketola, Raimo A.
    Auriola, Seppo
    Poutanen, Matti
    Kostiainen, Risto
    ANALYTICA CHIMICA ACTA, 2012, 721 : 115 - 121
  • [3] The Application of Chromatography-Mass Spectrometry: Methods to Metabonomics
    Wu, Zeming
    Huang, Zhiqiang
    Lehmann, Rainer
    Zhao, Chunxia
    Xu, Guowang
    CHROMATOGRAPHIA, 2009, 69 : S23 - S32
  • [4] Analysis of milk with liquid chromatography-mass spectrometry: a review
    Imperiale, Sebastian
    Morozova, Ksenia
    Ferrentino, Giovanna
    Scampicchio, Matteo
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2023, 249 (04) : 861 - 902
  • [5] Validation of lipidomic analysis of human plasma and serum by supercritical fluid chromatography-mass spectrometry and hydrophilic interaction liquid chromatography-mass spectrometry
    Wolrab, Denise
    Chocholouskova, Michaela
    Jirasko, Robert
    Peterka, Ondrej
    Holcapek, Michal
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (10) : 2375 - 2388
  • [6] Classification of natural resins by liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry using chemometric analysis
    Rhourrhi-Frih, B.
    West, C.
    Pasquier, L.
    Andre, P.
    Chaimbault, P.
    Lafosse, M.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1256 : 177 - 190
  • [7] Applications of liquid chromatography-mass spectrometry for food analysis
    Di Stefano, Vita
    Avellone, Giuseppe
    Bongiorno, David
    Cunsolo, Vincenzo
    Muccilli, Vera
    Sforza, Stefano
    Dossena, Arnaldo
    Drahos, Laszlo
    Vekey, Karoly
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 : 74 - 85
  • [8] Protein glycosylation analysis by liquid chromatography-mass spectrometry
    Wuhrer, M
    Deelder, AM
    Hokke, CH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (02): : 124 - 133
  • [9] Derivatization for liquid chromatography-mass spectrometry
    Qi, Bao-Ling
    Liu, Ping
    Wang, Qiu-Yi
    Cai, Wen-Jing
    Yuan, Bi-Feng
    Feng, Yu-Qi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 59 : 121 - 132
  • [10] Recent applications of liquid chromatography-mass spectrometry to residue analysis of antimicrobials in food of animal origin
    Bogialli, Sara
    Di Corcia, Antonio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (04) : 947 - 966