Dual-Energy Processing of X-ray Images of Beryl in Muscovite Obtained Using Pulsed X-ray Sources

被引:4
作者
Komarskiy, Alexander [1 ]
Korzhenevskiy, Sergey [1 ]
Ponomarev, Andrey [1 ]
Chepusov, Alexander [1 ]
机构
[1] Russian Acad Sci, Inst Electrophys, Ural Branch, Ekaterinburg 620016, Russia
基金
俄罗斯科学基金会;
关键词
dual-energy X-ray imaging; X-ray absorption; pulsed X-ray source; computed tomography; beryl; muscovite; image processing; TOMOGRAPHY; DIAMOND; DENSITY;
D O I
10.3390/s23094393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the development of a method for dual-energy processing of X-ray images using pulsed X-ray sources for the contrast detection of beryl in muscovite mica in 2D X-ray and CT images. These substances have similar chemical properties and are difficult to differentiate when one is against the background of the other using methods based on X-ray absorption. In the experiments, we used three pulsed X-ray sources with different maximum voltages. We performed modeling of the emission spectra and selection of the necessary energy bands due to X-ray absorbing filters: a positive effect was shown for dual-energy image processing when the function of converting X-ray radiation into a signal using the VIVIX-V 2323D detector was taken into account. As a result, a pulsed X-ray source with the pulse voltage of 330 kV was chosen for the contrast detection of beryl, with the content of 5-7% against the background of muscovite and the thickness up to 70 mm. Using this source and the developed mathematical algorithms, it is possible to obtain a band of low-energy radiation at the level of 70-80 keV, as well as high-energy radiation in the range of 180 keV. Methods based on the X-ray absorption can become both additional and independent methods for studying and monitoring membranes; these objects range from tens of nanometers to several micrometers in size.
引用
收藏
页数:18
相关论文
共 50 条
[21]   Body composition assessment by dual-energy X-ray absorptiometry (DXA) [J].
Andreoli, A. ;
Scalzo, G. ;
Masala, S. ;
Tarantino, U. ;
Guglielmi, G. .
RADIOLOGIA MEDICA, 2009, 114 (02) :286-300
[22]   Dual-Energy X-ray Imaging by Simultaneous Integration and Campbelling Readout [J].
Roessl, Ewald ;
Thran, Axel ;
Martens, Gerhard ;
Istel, Thomas ;
Proksa, Roland ;
Schlomka, Jens-Peter .
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, :2112-2115
[23]   The Methods of Processing of Microfocus X-ray Images [J].
Staroverov, Nikolay E. ;
Kholopova, Ekaterina D. ;
Gryaznov, Artem Yu. ;
Zhamova, Karina K. .
PROCEEDINGS OF THE 2017 IEEE RUSSIA SECTION YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (2017 ELCONRUS), 2017, :745-747
[24]   Method for obtaining and dual-energy processing of X-ray sinograms for identifying low-contrast ubstances in CT using sources with a continuous radiation spectrum [J].
Komarskiy, A. A. ;
Korzhenevskiy, S. R. ;
Krinitsin, V. V. .
COMPUTER OPTICS, 2025, 49 (02) :282-291
[25]   Noninterferometric phase-contrast images obtained with incoherent x-ray sources [J].
Olivo, Alessandro ;
Ignatyev, Konstantin ;
Munro, Peter R. T. ;
Speller, Robert D. .
APPLIED OPTICS, 2011, 50 (12) :1765-1769
[26]   Enhanced contrast in X-ray microtomographic images of the membranous labyrinth using different X-ray sources and scanning modes [J].
Goyens, Jana ;
Vasilopoulou-Kampitsi, Menelia ;
Claes, Raf ;
Sijbers, Jan ;
Mancini, Lucia .
JOURNAL OF ANATOMY, 2018, 233 (06) :770-782
[27]   Investigation of dual-energy X-ray photon counting using a cadmium telluride detector with dual-energy selection electronics [J].
Sato, Eiichi ;
Kosuge, Yoshiyuki ;
Yamanome, Hayato ;
Mikata, Aldko ;
Miura, Tatsuya ;
Oda, Yasuyuki ;
Ishii, Tomotaka ;
Hagiwara, Osahiko ;
Matsukiyo, Hiroshi ;
Watanabe, Manabu ;
Kusachi, Shinya .
RADIATION PHYSICS AND CHEMISTRY, 2017, 130 :385-390
[28]   Comparison of Methods for Modifying the Emission Spectrum of a Pulsed X-ray Source to Determine the Most Effective Dual-Energy Image Processing [J].
Komarskiy, A. A. ;
Korzhenevskiy, S. R. ;
Ponomarev, A. V. ;
Chepusov, A. S. ;
Krinitzin, V. V. ;
Krasniy, O. D. .
RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2024, 60 (09) :1040-1050
[29]   Validity and reliability of dual-energy X-ray absorptiometry for the assessment of abdominal adiposity [J].
Glickman, SG ;
Marn, CS ;
Supiano, MA ;
Dengel, DR .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (02) :509-514
[30]   Application of conventional- and dual-energy X-ray tomography in process engineering [J].
Gehrke, S ;
Wirth, KE .
IEEE SENSORS JOURNAL, 2005, 5 (02) :183-187