Dual-Energy Processing of X-ray Images of Beryl in Muscovite Obtained Using Pulsed X-ray Sources

被引:4
|
作者
Komarskiy, Alexander [1 ]
Korzhenevskiy, Sergey [1 ]
Ponomarev, Andrey [1 ]
Chepusov, Alexander [1 ]
机构
[1] Russian Acad Sci, Inst Electrophys, Ural Branch, Ekaterinburg 620016, Russia
基金
俄罗斯科学基金会;
关键词
dual-energy X-ray imaging; X-ray absorption; pulsed X-ray source; computed tomography; beryl; muscovite; image processing; TOMOGRAPHY; DIAMOND; DENSITY;
D O I
10.3390/s23094393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the development of a method for dual-energy processing of X-ray images using pulsed X-ray sources for the contrast detection of beryl in muscovite mica in 2D X-ray and CT images. These substances have similar chemical properties and are difficult to differentiate when one is against the background of the other using methods based on X-ray absorption. In the experiments, we used three pulsed X-ray sources with different maximum voltages. We performed modeling of the emission spectra and selection of the necessary energy bands due to X-ray absorbing filters: a positive effect was shown for dual-energy image processing when the function of converting X-ray radiation into a signal using the VIVIX-V 2323D detector was taken into account. As a result, a pulsed X-ray source with the pulse voltage of 330 kV was chosen for the contrast detection of beryl, with the content of 5-7% against the background of muscovite and the thickness up to 70 mm. Using this source and the developed mathematical algorithms, it is possible to obtain a band of low-energy radiation at the level of 70-80 keV, as well as high-energy radiation in the range of 180 keV. Methods based on the X-ray absorption can become both additional and independent methods for studying and monitoring membranes; these objects range from tens of nanometers to several micrometers in size.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] APPLICATION OF A DUAL-ENERGY MONOCHROMATIC X-RAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY
    Chang, S.
    Lee, H. K.
    Cho, G.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2012, 44 (01) : 61 - 70
  • [2] X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)
    Kim, Kwang Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2155 - 2158
  • [3] Capabilities of Dual-Energy X-Ray Imaging in Medicine and Security
    Ryzhikov, Volodymyr D.
    Grinyov, Borys V.
    Opolonin, Oleksandr D.
    Galkin, Serhiy M.
    Lysetska, Olena K.
    Voronkin, Yevheniy F.
    Kostioukevitch, Serhiy A.
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS XIII, 2012, 8509
  • [4] Resolution enhancement in dual-energy x-ray imaging
    Gravel, P
    Després, P
    Beaudoin, G
    de Guise, JA
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 614 - 624
  • [5] Distribution of electron density using dual-energy X-ray CT
    Tsunoo, T
    Torikoshi, M
    Sasaki, M
    Endo, M
    Yagi, N
    Uesugi, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1678 - 1682
  • [6] Inspection of cargo using dual-energy X-ray radiography: A review
    Moshkbar-Bakhshayesh, Khalil
    Afarideh, Hossein
    Azimirad, Rouhollah
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [7] Identification of materials in X-Ray inspections of objects by the dual-energy method
    Osipov, S. P.
    Udod, V. A.
    Wang, Y.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2017, 53 (08) : 568 - 587
  • [8] Rock porosity quantification by dual-energy X-ray computed microtomography
    Teles, A. P.
    Lima, I.
    Topes, R. T.
    MICRON, 2016, 83 : 72 - 78
  • [9] Dual-Energy X-Ray Absorptiometry for Quantification of Visceral Fat
    Kaul, Sanjiv
    Rothney, Megan P.
    Peters, Dawn M.
    Wacker, Wynn K.
    Davis, Cynthia E.
    Shapiro, Michael D.
    Ergun, David L.
    OBESITY, 2012, 20 (06) : 1313 - 1318
  • [10] Parameter identification method for dual-energy X-ray imaging
    Osipov, Sergei
    Libin, Eduard
    Chakhlov, Sergei
    Osipov, Oleg
    Shtein, Alexander
    NDT & E INTERNATIONAL, 2015, 76 : 38 - 42