Two peak elution behavior of a monoclonal antibody in cation exchange chromatography as a screening tool for excipients

被引:2
|
作者
Stange, Carolin [1 ]
Hafiz, Supriyadi [2 ]
Erwin, Nelli [2 ]
Hafner, Mathias [3 ]
Frech, Christian [1 ,4 ]
机构
[1] Univ Appl Sci Mannheim, Inst Biochem, D-68163 Mannheim, Germany
[2] Merck KGaA, D-64293 Darmstadt, Germany
[3] Univ Appl Sci Mannheim, Inst Mol Biol & Cell Culture Technol, D-68163 Mannheim, Germany
[4] Univ Appl Sci Mannheim, Inst Biochem, Paul Wittsack Str 10, D-68163 Mannheim, Germany
关键词
Two peak elution behavior; Cation exchange chromatography; Unfolding; Aggregation; Temperature; Excipients; PROTEIN STABILIZATION; STABILITY; AGGREGATION; MECHANISM; ARGININE; TAURINE; STORAGE;
D O I
10.1016/j.jchromb.2022.123563
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aggregation of proteins is a critical quality attribute and a major concern during the purification of therapeutic proteins, like monoclonal antibodies. In-solution experiments applying different stress scenarios, e.g., mechan-ical, or physical stresses, can determine the overall conformational stability of the protein to enhance drug product shelf-life. Several groups have reported surface-induced unfolding and aggregation of monoclonal an-tibodies and their derivatives during cation exchange chromatography, which results in a two-peak elution behavior of the protein and its species. We have investigated universal influencing factors, like temperature and hold time, on this phenomenon. The formation of the second peak is a kinetic process, which is strongly influ-enced by temperature during the hold time. However, our main focus was the application of excipients and their influence on the two-peak elution behavior. We compared the on-column screening results with results obtained through a "traditional" in-solution screening using nanoDSF. Mostly, stabilizing excipients, like Sucrose, show their stabilizing abilities in both systems, but some discrepancies, e.g., using Arginine, between the two orthogonal techniques show the potential of the on-column screening system to lead to unexpected results, which would not necessarily be visible in in-solution experiments.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Characterization of the glycosylation state of a recombinant monoclonal antibody using weak cation exchange chromatography and mass spectrometry
    Gaza-Bulseco, Georgeen
    Bulseco, Ashley
    Chumsae, Chris
    Liu, Hongcheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 155 - 160
  • [32] Separation of monoclonal antibody charge variants using cation exchange chromatography: Resins and separation conditions optimization
    Jing, Shu-Ying
    Gou, Jin-Xia
    Gao, Dong
    Wang, Hai-Bin
    Yao, Shan-Jing
    Lin, Dong-Qiang
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 235 (235)
  • [33] Preparative separation of monoclonal antibody aggregates by cation-exchange laterally-fed membrane chromatography
    Madadkar, Pedram
    Sadavarte, Rahul
    Butler, Michael
    Durocher, Yves
    Ghosh, Raja
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1055 : 158 - 164
  • [34] Characterization of the Acidic Species of a Monoclonal Antibody Using Weak Cation Exchange Chromatography and LC-MS
    Ponniah, Gomathinayagam
    Kita, Adriana
    Nowak, Christine
    Neill, Alyssa
    Kori, Yekaterina
    Rajendran, Saravanamoorthy
    Liu, Hongcheng
    ANALYTICAL CHEMISTRY, 2015, 87 (17) : 9084 - 9092
  • [35] Antibody aggregation and unfolding on cation exchange chromatography media
    Guo, Jing
    Fernandez, Erik J.
    O'Connell, John P.
    Carta, Giorgio
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [36] Optimization of monoclonal antibody purification by ion-exchange chromatography - Application of simple methods with linear gradient elution experimental data
    Ishihara, T
    Yamamoto, S
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1069 (01) : 99 - 106
  • [37] Prediction tool for loading, isocratic elution, gradient elution and scaling up of ion exchange chromatography of proteins
    Marek, Wojciech Kazimierz
    Sauer, Dominik
    Duerauer, Astrid
    Jungbauer, Alois
    Piatkowski, Wojciech
    Antos, Dorota
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1566 : 89 - 101
  • [38] PEAK COMPRESSION IN STEPWISE PH ELUTION WITH FLOW REVERSAL IN ION-EXCHANGE CHROMATOGRAPHY
    KIM, SU
    BERNINGER, JA
    YU, QM
    WANG, NHL
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1992, 31 (07) : 1717 - 1730
  • [39] MUTUAL SEPARATION OF RARE-EARTHS IN MONAZITE WITH CATION-EXCHANGE ELUTION CHROMATOGRAPHY
    CHEN, YM
    SUNG, NKY
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1975, 22 (02) : 113 - 127
  • [40] Adsorption of monoclonal antibody variants on analytical cation-exchange resin
    Melter, Lena
    Stroehlein, Guido
    Butte, Alessandro
    Morbidelli, Massimo
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 121 - 131