Two peak elution behavior of a monoclonal antibody in cation exchange chromatography as a screening tool for excipients

被引:2
|
作者
Stange, Carolin [1 ]
Hafiz, Supriyadi [2 ]
Erwin, Nelli [2 ]
Hafner, Mathias [3 ]
Frech, Christian [1 ,4 ]
机构
[1] Univ Appl Sci Mannheim, Inst Biochem, D-68163 Mannheim, Germany
[2] Merck KGaA, D-64293 Darmstadt, Germany
[3] Univ Appl Sci Mannheim, Inst Mol Biol & Cell Culture Technol, D-68163 Mannheim, Germany
[4] Univ Appl Sci Mannheim, Inst Biochem, Paul Wittsack Str 10, D-68163 Mannheim, Germany
关键词
Two peak elution behavior; Cation exchange chromatography; Unfolding; Aggregation; Temperature; Excipients; PROTEIN STABILIZATION; STABILITY; AGGREGATION; MECHANISM; ARGININE; TAURINE; STORAGE;
D O I
10.1016/j.jchromb.2022.123563
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aggregation of proteins is a critical quality attribute and a major concern during the purification of therapeutic proteins, like monoclonal antibodies. In-solution experiments applying different stress scenarios, e.g., mechan-ical, or physical stresses, can determine the overall conformational stability of the protein to enhance drug product shelf-life. Several groups have reported surface-induced unfolding and aggregation of monoclonal an-tibodies and their derivatives during cation exchange chromatography, which results in a two-peak elution behavior of the protein and its species. We have investigated universal influencing factors, like temperature and hold time, on this phenomenon. The formation of the second peak is a kinetic process, which is strongly influ-enced by temperature during the hold time. However, our main focus was the application of excipients and their influence on the two-peak elution behavior. We compared the on-column screening results with results obtained through a "traditional" in-solution screening using nanoDSF. Mostly, stabilizing excipients, like Sucrose, show their stabilizing abilities in both systems, but some discrepancies, e.g., using Arginine, between the two orthogonal techniques show the potential of the on-column screening system to lead to unexpected results, which would not necessarily be visible in in-solution experiments.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Influence of ligand density variations on the two peak elution behavior of a monoclonal antibody in cation exchange chromatography
    Stange, Carolin
    Sanchez-Reyes, Gabriela
    Graalfs, Heiner
    Frech, Christian
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1680
  • [2] Influence of ligand density variations on the two peak elution behavior of a monoclonal antibody in cation exchange chromatography
    Stange, Carolin
    Sánchez-Reyes, Gabriela
    Graalfs, Heiner
    Frech, Christian
    Journal of Chromatography A, 2022, 1680
  • [3] Surface induced three-peak elution behavior of a monoclonal antibody during cation exchange chromatography
    Guo, Jing
    Creasy, Arch D.
    Barker, Gregory
    Carta, Giorgio
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1474 : 85 - 94
  • [4] Two-peak elution behavior of therapeutic IgG4 on cation exchange chromatography
    Chen, Zhiqiang
    Wang, Mian
    Xu, Xuankuo
    Ghose, Sanchayita
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [5] Rapid development of cation exchange chromatography step elution for monoclonal antibody purification
    Young, Lucian
    Cai, Katherine
    Varma, Amit
    Huang, Ping Y.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [6] Influence of ligand density on two-peak elution behavior of mAb charge variants in cation exchange chromatography
    Reyes, Gabriela Sanchez
    Stange, Carolin
    Frech, Christian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [7] Effects of salt-induced reversible self-association on the elution behavior of a monoclonal antibody in cation exchange chromatography
    Luo, Haibin
    Macapagal, Nathaniel
    Newell, Kelcy
    Man, Adrian
    Parupudi, Arun
    Li, Yiming
    Li, Yuling
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1362 : 186 - 193
  • [8] Double-peak elution profile of a monoclonal antibody in cation exchange chromatography is caused by histidine-protonation-based charge variants
    Luo, Haibin
    Cao, Mingyan
    Newell, Kelcy
    Afdahl, Christopher
    Wang, Jihong
    Wang, William K.
    Li, Yuling
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1424 : 92 - 101
  • [9] Robustness assessment of cation-exchange chromatography with in-silico peak deconvolution in monoclonal antibody purification
    Kitamura, Ryunosuke
    Aiso, Takaki
    Kawatsu, Kosaku
    Masuda, Yumiko
    Kawabe, Takefumi
    Nonaka, Koichi
    Yonemochi, Etsuo
    JOURNAL OF CHROMATOGRAPHY OPEN, 2022, 2
  • [10] pH-based cation exchange chromatography in the capture and elution of monoclonal antibodies
    Ng, Paul K.
    Snyder, Mark A.