A Novel Multiobjective Function for Finite-Element Model Updating of a Long-Span Cable-Stayed Bridge Using In Situ Static and Dynamic Measurements

被引:11
|
作者
Qin, Shiqiang [1 ]
Yuan, Yonggang [1 ]
Han, Shuo [1 ]
Li, Shiwei [2 ]
机构
[1] Wuhan Univ Technol, Sch Civil Engn & Architecture, Wuhan 430070, Peoples R China
[2] Kunming Univ Sci & Technol, Fac Civil Engn & Mech, Kunming 650500, Peoples R China
关键词
Finite-element model updating; Kriging model; Global sensitivity analysis; Displacement assurance criterion; Multiobjective optimization; Cable-stayed bridge; Neutral axis; NEUTRAL AXIS TRACKING; DAMAGE DETECTION; IDENTIFICATION;
D O I
10.1061/(ASCE)BE.1943-5592.0001974
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The traditional objective function (TOF) of bridge model updating is usually defined on the basis of the structural response residuals between numerically calculated and experimentally measured values. However, this model finds it difficult to determine the weighting factors, and the updated model lacks accuracy. To offset these disadvantages, this study proposes a novel objective function (NOF) for finite-element model updating of a long-span cable-stayed bridge using in situ static and dynamic measurements. The proposed NOF comprises the residual functions of the displacement assurance criterion, the position of the neutral axis, and the natural frequency. The global sensitivity analysis-based model updating uses the Kriging model as the surrogate model to save computational costs. The nondominated sorting genetic algorithm II is employed to find the Pareto solutions. The updating results with the TOF defined directly using displacement, stress, and frequency are listed for the purposes of comparison. The results show that the NOF avoids determining the weighting factors and provides more accurate results than the TOF. The updated displacement curves, the position of the neutral axis, and the frequencies obtained from the NOF are all closer to the experimentally measured ones than those obtained from the TOF. After model updating, the displacement's relative errors are around 5% without considering the displacement values under 10 mm. The relative errors of the first four frequencies are all less than 10%. The updated model can serve as the baseline finite-element model of the bridge.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Evaluation of long-service-life cable-stayed bridge strengthening schemes using a two-phase finite element model updating technology
    Qiu, Kai
    Li, Shuchen
    Sun, Huahuai
    Wang, Youzhi
    Lv, Bin
    STRUCTURES, 2023, 47 : 625 - 637
  • [32] Bayesian Finite Element Model Updating and Assessment of Cable-Stayed Bridges Using Wireless Sensor Data
    Asadollahi, Parisa
    Huang, Yong
    Li, Jian
    SENSORS, 2018, 18 (09)
  • [33] Study on Dynamic Characteristics of Long-Span Highway-Rail Double-Tower Cable-Stayed Bridge
    Guo, Shijie
    Jiang, Yuhang
    Zhang, Wenli
    Zeng, Yong
    BUILDINGS, 2024, 14 (06)
  • [34] Dynamic Response of Railway Vehicles Running on Long-Span Cable-Stayed Bridge Under Uniform Seismic Excitations
    Li, Yongle
    Zhu, Siyu
    Cai, C. S.
    Yang, Cheng
    Qiang, Shizhong
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2016, 16 (05)
  • [35] Framework of Nonlinear Dynamic Simulation of Long-Span Cable-Stayed Bridge and Traffic System Subjected to Cable-Loss Incidents
    Zhou, Yufen
    Chen, Suren
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (03)
  • [36] Dynamic Analysis of Suspension-Type Monorail Long-Span Cable-Stayed Bridge in a Wind-Vehicle-Bridge System
    Zhu, Bing
    Zhang, Chengran
    Zhang, Zhen
    Luo, Lei
    Bai, Xiaozu
    URBAN RAIL TRANSIT, 2023, 9 (01) : 19 - 30
  • [37] Dynamic Analysis of Suspension-Type Monorail Long-Span Cable-Stayed Bridge in a Wind-Vehicle-Bridge System
    Bing Zhu
    Chengran Zhang
    Zhen Zhang
    Lei Luo
    Xiaozu Bai
    Urban Rail Transit, 2023, 9 : 19 - 30
  • [38] Geometry control of long-span continuous girder concrete bridge during construction through finite element model updating
    Wu, Jie
    Yan, Quan-sheng
    Li, Jian
    Hu, Min-yi
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2016, 2016, 9805
  • [39] Automated modal identification using principal component and cluster analysis: Application to a long-span cable-stayed bridge
    Mao, Jian-Xiao
    Wang, Hao
    Fu, Yu-Guang
    Spencer, Billie F., Jr.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (10)
  • [40] Model calibration of a long-span concrete cable-stayed bridge based on structural health monitoring data: Influence of concrete variability
    Natalicchio, Cortney
    Al-Khateeb, Hadi
    Chajes, Michael J.
    Wu, Zheng Y.
    Shenton, Harry W., III
    BRIDGE STRUCTURES, 2022, 18 (1-2) : 45 - 62