Mechanical and chemical characterization of contemporary occlusal splint materials fabricated with different methods: a systematic review

被引:8
作者
Benli, Merve [1 ,2 ]
Husain, Nadin Al-Haj [3 ,4 ,5 ]
Ozcan, Mutlu [6 ,7 ]
机构
[1] MUSC, Dept Oral Rehabil, James B Edwards Coll Dent Med, Charleston, SC 29425 USA
[2] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[3] Univ Zurich, Ctr Dent Med, Div Dent Biomat, Clin Reconstruct Dent, CH-8032 Zurich, Switzerland
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[5] Univ Zurich, Ctr Dent Med, Clin Masticatory Disorders, CH-8032 Zurich, Switzerland
[6] Univ Zurich, Ctr Dent Med, Div Dent Biomat, Clin Reconstruct Dent, Plattenstr 11, CH-8032 Zurich, Switzerland
[7] Univ Zurich, Ctr Dent Med, Clin Chewing Funct Disturbances, Clin Reconstruct Dent, Plattenstr 11, CH-8032 Zurich, Switzerland
关键词
Oral appliances; Digital splints; Bruxism; 3D printing; Occlusal devices; TEMPOROMANDIBULAR DISORDER; 2-BODY WEAR; POLISHABILITY; CONVERSION; POLYAMIDE; POLYMERS; HARDNESS; PAIN;
D O I
10.1007/s00784-023-05360-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo systematically review studies on various occlusal splint materials and describe their mechanical and chemical properties.MethodsMEDLINE (PubMed), Scopus, and Web of Science searches were conducted for in vitro studies focusing on occlusal splint materials. Two reviewers performed an assessment of the identified studies and data abstraction independently, and this was complimented by an additional hand search. The articles were limited to those in the English language that were published between January 1st, 2012, and December 1st, 2022.ResultsThe initial search yielded 405 search results of which 274 were selected for full-text review following abstract evaluation. 250 articles that did not meet the inclusion criteria were excluded, and the remaining 25 articles (with 1 article identified from the reference lists of included articles) providing mechanical and chemical values were used in this review. Poly methyl methacrylate (PMMA) -based occlusal splint materials showed the highest values in terms of hardness, wear resistance, flexural strength, flexural modulus, e-modulus, and fracture toughness. The material group with the highest water sorption and water solubility was 3D printed (PR) splint materials. In addition, the lowest degree of double bond conversion was also observed in this group of materials.ConclusionsThe outcome of this review suggests that mechanically and chemically acceptable properties can be attained with PMMA-based occlusal splint materials using both conventional and digital production methods. PR splint materials should not be considered as the primary choice for long-term treatments due to their low mechanical and chemical properties.Clinical RelevanceThis review provides clinical recommendations for selecting the appropriate material and fabrication method for occlusal splints while taking the patients' needs and the materials ' mechanical and chemical properties into account.
引用
收藏
页码:7115 / 7141
页数:27
相关论文
共 56 条
  • [1] Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations
    Alharbi, Nawal
    Osman, Reham
    Wismeijer, Daniel
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06) : 760 - 767
  • [2] Alifui-Segbaya Frank, 2019, Compend Contin Educ Dent, V40, pe7
  • [3] Thermal, structural and morphological characterization of dental polymers for clinical applications
    Benli, Merve
    Gumus, Beril Eker
    Kahraman, Yusuf
    Yagci, Ozlem
    Erdogan, Duygu
    Huck, Olivier
    Ozcan, Mutlu
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (02) : 176 - 185
  • [4] A novel treatment modality for myogenous temporomandibular disorders using aromatherapy massage with lavender oil: A randomized controlled clinical trial
    Benli, Merve
    Olson, Jessica
    Huck, Olivier
    Ozcan, Mutlu
    [J]. CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2023, 41 (01): : 48 - 58
  • [5] Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers
    Benli, Merve
    Gumus, Beril Eker
    Kahraman, Yusuf
    Gokcen-Rohlig, Bilge
    Evlioglu, Gulumser
    Huck, Olivier
    Ozcan, Mutlu
    [J]. ODONTOLOGY, 2020, 108 (02) : 240 - 250
  • [6] Comparing the mechanical properties of pressed, milled, and 3D-printed resins for occlusal devices
    Berli, Constantin
    Thieringer, Florian M.
    Sharma, Neha
    Muller, Johannes A.
    Dedem, Philipp
    Fischer, Jens
    Rohr, Nadja
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06) : 780 - 786
  • [7] Duymus Z.Y., 2016, OPEN J STOMATOL, V6, P114, DOI DOI 10.4236/OJST.2016.64014
  • [8] CAD/CAM splints for the functional and esthetic evaluation of newly defined occlusal dimensions
    Edelhoff, Daniel
    Schweiger, Josef
    Prandtner, Otto
    Trimpl, Johannes
    Stimmelmayr, Michael
    Gueth, Jan-Frederik
    [J]. QUINTESSENCE INTERNATIONAL, 2017, 48 (03): : 181 - 191
  • [9] Treatment outcome of appliance therapy in temporomandibular disorder patients with myofascial pain after 6 and 12 months
    Ekberg, E
    Nilner, M
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2004, 62 (06) : 343 - 349
  • [10] Additive manufacturing of ceramics for dental applications: A review
    Galante, Raquel
    Figueiredo-Pina, Celio G.
    Serro, Ana Paula
    [J]. DENTAL MATERIALS, 2019, 35 (06) : 825 - 846