Altitude Correction Method for Audible Noise of ± 800 kV UHVdc Overhead Transmission Line and its Engineering Application

被引:5
|
作者
Zhao, Luxing [1 ]
Xie, Li [1 ]
Wang, Dafei [2 ]
He, Kun [1 ]
Gao, Lei [2 ]
Ju, Yong [1 ]
Lu, Jiayu [1 ]
机构
[1] China Elect Power Res Inst Co Ltd, Beijing 100192, Peoples R China
[2] State Grid Tibet Elect Power Co Ltd, Elect Power Res Inst, Lhasa 850001, Peoples R China
关键词
UHVdc; overhead transmission line; corona discharge; audible noise; test line; altitude correction; engineering application;
D O I
10.1109/TPWRD.2023.3273714
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the improvement of the voltage level of DC overhead transmission lines (OHTLs), the audible noise (AN) caused by the corona discharge of conductors is an increasingly serious problem. AN has become a critical parameter that determines the selection of conductors, line structures and specifications for UHVdc OHTLs in high-altitude areas. To study the altitude correction method of AN for UHVdc OHTLs, we erected 6 x 720 mm(2) and 6 x 900 mm(2) conductors on DC full-scale test lines located at altitudes of 4,300 m and 50 m, respectively. We carried out an experimental study on AN over a long period and obtained its distribution law at high and low altitudes and its altitude-related increment. At the same time, on four DC reduced-scale test lines located at 4,300 m, 3,400 m, 1,700 m and 50 m above sea level, 6 x 95 mm(2) conductors were erected for experiments. The law that the AN of the DC OHTL shows a nonlinear change with increasing altitude is obtained. Based on the combination of full-scale and reduced-scale tests, an altitude correction method of AN for UHVdc OHTLs considering the influences of both altitude and electric field strength on the conductor surface is proposed. From 0 to 4,300 m above sea level, when the maximum electric field strength on the conductor surface is 19 kV/cm, the increase in AN calculated with the formula suggested by this article is only 55% of the value calculated with the method recommended by the EPRI. The altitude correction formula of AN proposed herein is applicable to the design of UHVdc OHTLs in high-altitude areas, which can greatly save line investment while meeting the requirements of environmental protection.
引用
收藏
页码:3375 / 3386
页数:12
相关论文
共 50 条
  • [41] Designing and Application of High Voltage Overhead Transmission Line Typhoon Disaster Prediction Method
    Zhou, Xiangxian
    Li, Te
    Jiang, Wendong
    Mei, Binxiao
    Zou, Yang
    Li, Lin
    PROCEEDINGS OF 2019 INTERNATIONAL FORUM ON SMART GRID PROTECTION AND CONTROL (PURPLE MOUNTAIN FORUM), VOL II, 2020, 585 : 769 - 777
  • [42] Spectrum characters of the audible noise from ±500 kV Ge-Nan and Yi-Hua transmission line and affecting factors
    Lu, Yao
    Qi, Xiao-Man
    Zhang, Guang-Zhou
    Wan, Bao-Quan
    Zhang, Ze-Ping
    Ni, Yuan
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (11): : 2754 - 2759
  • [43] Traveling Wave Differential Protection Technology and Its Application in Ultra-Long-Distance UHVDC Transmission Line
    Dong, Xinzhou
    Wang, Haozong
    Chen, Binshu
    Jin, Boliang
    Li, Xinyuan
    Dong, Qihuan
    Shi, Shenxing
    Wang, Bin
    Lv, Pengfei
    Qian, Guoming
    Chen, Fufeng
    Fan, Zhanfeng
    Li, Baowei
    Xie, Min
    Feng, Xiaoping
    IEEE TRANSACTIONS ON POWER DELIVERY, 2025, 40 (02) : 1078 - 1088
  • [44] Dynamic Response of Overhead Transmission Line in Turbulent Wind Flow with Application of the Spectral Element Method
    Dutkiewicz, Maciej
    Machado, Marcela R.
    3RD WORLD MULTIDISCIPLINARY CIVIL ENGINEERING, ARCHITECTURE, URBAN PLANNING SYMPOSIUM (WMCAUS 2018), 2019, 471
  • [45] Reduction of audible noise using asymmetrical bundles for 1000 kV transmission lines: Full-scale test results of Akagi test line
    Tanabe, K
    Takebe, T
    Isozaki, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1482 - 1491
  • [46] Application Research on Large Cross-section Profile Conductors in ±800 kV DC Transmission Line with Large Capacity
    Liu, Zhen
    Li, Dong Qing
    Liu, Long
    Zhu, Kuan Jun
    Chen, Yuan
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY V, 2015, : 834 - 840
  • [47] A new method for live line measurement of zero-sequence parameters of transmission line containing t-connection transmission line with mutual inductance and its engineering application
    Fang, Li-Hua
    Hu, Zhi-Jian
    Dianwang Jishu/Power System Technology, 2010, 34 (04): : 204 - 208
  • [48] Finite Element Method Based Simulations of the Magnetic Fields Around the Overhead Transmission Line and Its Dosimetric Analysis
    Ates, Kayhan
    Ozen, Sukni
    Carlak, H. Feza
    2019 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO 2019), 2019, : 642 - 645
  • [49] Quantum Transmission Line Modeling Method and Its Application to Quantum Dot Amplifiers
    Xia, Mingjun
    Ghafouri-Shiraz, Hooshang
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 2016, 52 (05)
  • [50] "Virtual" Power Line Method to Correct the Calculation of Current Ground Faults in the Parallel Overhead Transmission Lines 110-220 kV
    Ukraintsev, A., V
    Nagay, I., V
    2016 2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2016,