Evaluation of the efficacy and safety of day surgery for cervical disc herniation treated with low temperature plasma radiofrequency ablation

被引:0
|
作者
An, Zhongcheng [1 ]
Fan, Guangya [1 ,2 ]
Su, Wenshuo [1 ,2 ]
Chen, Chen [1 ]
Lai, Tingyuan [1 ]
Dong, Liqiang [1 ]
机构
[1] Zhejiang Chinese Med Univ, Affiliated Hosp 2, Dept Orthoped & Traumatol, Hangzhou 310005, Zhejiang, Peoples R China
[2] Zhejiang Chinese Med Univ, Clin Med Coll 2, Hangzhou 310005, Zhejiang, Peoples R China
关键词
Low-temperature plasma radiofrequency ablation; Cervical disc herniation; Day surgery procedure; Traditional inpatient procedure; NUCLEOPLASTY;
D O I
10.1007/s00264-023-05955-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this study was to evaluate and compare the clinical efficacy of patients with cervical disc herniation (CDH) treated by low-temperature plasma radiofrequency ablation (LTP-RFA) as day surgery with traditional inpatients. Methods According to the selection criteria, single-segment mild to moderate CDH patients who received LTP-RFA from January 2020 to December 2021 were divided into day surgery procedure (DSP) group and a traditional inpatient procedure (TIP) group. The visual analogue score (VAS) and modified Japanese Orthopedic Association score (mJOA) of neurological function of patients in the two groups were recorded at the time of preoperative, and one day, three months, six months after surgery and the last follow-up respectively. The gender, age, responsible segment, surgical complications, hospitalization time, hospitalization expenses, and patient satisfaction were recorded and analyzed for both groups. The modified Macnab standard was used to evaluate the postoperative efficacy at one month and six months after operation. Results A total of 127 patients (75 in DSP;52 in TIP) with complete data were enrolled and completed six month follow-up. There were no statistically significant pre-treatment VAS scores and mJOA scores in the two groups (P>0.05). The postoperative VAS and mJOA scores in both groups were improved after surgery (P<0.05). However, there was no significant difference in VAS scores and mJOA scores between the two groups in the same postoperative period (all P > 0.05). The efficacy of MacNab was similar one month and six months after operation (P > 0.05). The hospitalization time and hospitalization cost were significantly lower in DSP group (all P<0.05). As the treatment effects were comparable, patients in both groups were similarly satisfied at discharge. Conclusion LTP-RFA is an effective method for the treatment of mild to moderate CDH. We suggest that the application of LTP-RFA in DSP for mild to moderate CDH is worthy of wide application.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 26 条
  • [1] Evaluation of the efficacy and safety of day surgery for cervical disc herniation treated with low temperature plasma radiofrequency ablation
    Zhongcheng An
    Guangya Fan
    Wenshuo Su
    Chen Chen
    Tingyuan Lai
    Liqiang Dong
    International Orthopaedics, 2024, 48 : 211 - 219
  • [2] Clinical evaluation of CT-guided radiofrequency target thermocoagulation combined with ozone injection ablation for treatment of cervical disc herniation
    Zeng, Zhenhua
    Yan, Min
    Dai, Yi
    Deng, Shuo
    Zhou, Sanbao
    Yin, Jun
    Chen, Yanfei
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (03): : 2299 - 2305
  • [3] Clinical study on the efficacy and safety of percutaneous endoscopic anterior cervical discectomy in the treatment of cervical disc herniation
    Ma, Haijun
    Zhang, Haoping
    Zhou, Honggang
    Zhao, Xiaobing
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (05) : 1247 - 1256
  • [4] Clinical study on the efficacy and safety of percutaneous endoscopic anterior cervical discectomy in the treatment of cervical disc herniation
    Ma Haijun
    Zhang Haoping
    Zhou Honggang
    Zhao Xiaobing
    International Orthopaedics, 2021, 45 : 1247 - 1256
  • [5] Percutaneous plasma laser disc coagulation and navigable ablation decompression in the treatment of cervical disc herniation: a single center experience
    Ceylan, Aysegul
    Asik, Ibrahim
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (01) : 258 - 264
  • [6] Efficacy and safety of percutaneous endoscopic cervical discectomy for cervical disc herniation: a systematic review and meta-analysis
    Jinjie Zhang
    Qiujun Zhou
    Yan Yan
    Jianlei Ren
    Shenyu Wei
    Haijia Zhu
    Zhoufeng Song
    Journal of Orthopaedic Surgery and Research, 17
  • [7] Efficacy and safety of percutaneous endoscopic cervical discectomy for cervical disc herniation: a systematic review and meta-analysis
    Zhang, Jinjie
    Zhou, Qiujun
    Yan, Yan
    Ren, Jianlei
    Wei, Shenyu
    Zhu, Haijia
    Song, Zhoufeng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [8] CT-Guided Radiofrequency Ablation Targeting the Herniation Edge of the Cervical Disc for the Treatment of Neck Pain: A Retrospective Study
    Zhang, Nannan
    Hu, Jiaqi
    Cai, Wenjun
    Liu, Wenlong
    Li, Shun
    Ru, Bin
    PAIN AND THERAPY, 2024, 13 (01) : 87 - 97
  • [9] CT-Guided Radiofrequency Ablation Targeting the Herniation Edge of the Cervical Disc for the Treatment of Neck Pain: A Retrospective Study
    Nannan Zhang
    Jiaqi Hu
    Wenjun Cai
    Wenlong Liu
    Shun Li
    Bin Ru
    Pain and Therapy, 2024, 13 : 87 - 97
  • [10] Low-Temperature Plasma Radiofrequency Ablation for Congenital Epiglottic Cysts
    Cai, Hao
    Gao, Jinjian
    ENT-EAR NOSE & THROAT JOURNAL, 2024,