Development and validation of a chiral LC-MS method for the enantiomeric resolution of (+) and (-)-Mebeverine Hydrochloride in bulk drug by using polysaccharide-based chiral stationary phase

被引:0
|
作者
Gowramma, Byran [1 ]
Ramachandran, Senthil Kumar [2 ]
Lakshmanan, Kaviarasan [3 ]
Kalirajan, Rajagopal [1 ]
Meyyanathan, Subramanian Nainar [2 ]
Swaminathan, Gomathi [1 ]
机构
[1] JSS Acad Higher Educ & Res, JSS Coll Pharm, Dept Pharmaceut Chem, Nilgiris 643001, Tamil Nadu, India
[2] JSS Acad Higher Educ & Res, JSS Coll Pharm, Dept Pharmaceut Anal, Nilgiris 643001, Tamil Nadu, India
[3] Sathyabama Inst Sci & Technol, Sch Pharm, Dept Pharmaceut Chem, Chennai, Tamil Nadu, India
关键词
Chirality; ICH; Mebeverine; LC-MS; Enantiomers; Validation;
D O I
10.1080/22297928.2023.2244492
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study was to develop a simple, specific, sensitive and precise LC-MS method for the determination of mebeverine enantiomers in pharmaceutical formulations and it was validated as per ICH guidelines. The chromatographic separation was achieved on Phenomenex (R) Lux Cellulose 1 (250 mm x 4.6 mm i.d, 5 mu m particle size) column using mobile phase system containing acetonitrile: 10 mM ammonium acetate (85:15) at the flow rate of 0.8 mL/min. In the spectral investigation by LC-MS, the standard solution of Mebeverine showed major peak at m/z of 430.70, which was assigned to the [M+H] ion of Mebeverine. The described method was linear over the range of 15-75 ng /mL for (& PLUSMN;) Mebeverine enantiomers with a correlation coefficient (r2 = 0.999). Detection limits and quantification limits of (+) Mebeverine and (-) Mebeverine were found to be 5 ng/mL and 15 ng/mL respectively. The recovery study of mebeverine from tablet formulation was found to be 99.16%. Mebeverine standard solution and mobile phase were found to be stable for at least 48h. The Mebeverine enantiomers were well resolved with mean retention times of about 1.16 min and 1.20 min respectively. The developed method was extensively validated and proved to be robust, accurate, precise, and suitable for analysis of Mebeverine enantiomers in tablet dosage form.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 50 条
  • [31] Development and validation of sensitive methods for determination of sibutramine hydrochloride monohydrate and direct enantiomeric separation on a protein-based chiral stationary phase
    Universidade de São Paulo, Faculdade de Ciências Farmacêuticas, Departamento de Farmácia, CP 66355, CEP: 05315-970, São Paulo-SP, Brazil
    不详
    Journal of AOAC International, 1600, 91 (03): : 572 - 579
  • [32] Separation of Ketorolac enantiomers on polysaccharide-based chiral stationary phases using a polar organic mobile phase
    He, Yunchao
    Wu, Yaling
    Cheng, Lingping
    He, Shanshan
    Wang, Qiuhua
    Wang, Huiying
    Ke, Yanxiong
    SEPARATION SCIENCE PLUS, 2018, 1 (05): : 351 - 358
  • [33] Validation of LC method in determining enantiomeric purity of pramipexole using polysaccharide-derived chiral stationary phases under organic-aqueous mode
    Ching-Chia Chang
    Shu-Yu Fan
    Chi-Zong Zang
    Ya-Hui Hsu
    Mei-Chih Lin
    Der-Yuan Wang
    Hwei-Fang Cheng
    SN Applied Sciences, 2019, 1
  • [34] Validation of LC method in determining enantiomeric purity of pramipexole using polysaccharide-derived chiral stationary phases under organic-aqueous mode
    Chang, Ching-Chia
    Fan, Shu-Yu
    Zang, Chi-Zong
    Hsu, Ya-Hui
    Lin, Mei-Chih
    Wang, Der-Yuan
    Cheng, Hwei-Fang
    SN APPLIED SCIENCES, 2019, 1 (01):
  • [35] Pharmaceutical-enantiomers resolution using immobilized polysaccharide-based chiral stationary phases in supercritical fluid chromatography
    De Klerck, Katrijn
    Vander Heyden, Yvan
    Mangelings, Debby
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1328 : 85 - 97
  • [36] HPLC-FLUORESCENCE METHOD FOR THE ENANTIOSELECTIVE ANALYSIS OF PROPRANOLOL IN RAT SERUM USING IMMOBILIZED POLYSACCHARIDE-BASED CHIRAL STATIONARY PHASE
    AL-Suwailem, A. K.
    CARDIOLOGY, 2015, 131 : 386 - 386
  • [37] Enantioselective analysis of propafenone in plasma using a polysaccharide-based chiral stationary phase under reversed-phase conditions
    de Gaitani, CM
    Lanchote, VL
    Bonato, PS
    JOURNAL OF CHROMATOGRAPHY B, 1998, 708 (1-2): : 177 - 183
  • [38] Method Development and Validation for Determination of p-Toluenesulfonoxypropyl-(+)-Dihydrotetrabenazine Enantiomeric Purity by HPLC on a Chiral Stationary Phase
    Li, Xiaomin
    Chen, Zhengping
    Liu, Chunyi
    Tang, Jie
    Xue, Danlu
    Cao, Lihua
    Xu, Dong
    CHROMATOGRAPHIA, 2017, 80 (03) : 483 - 488
  • [39] Method Development and Validation for Determination of p-Toluenesulfonoxypropyl-(+)-Dihydrotetrabenazine Enantiomeric Purity by HPLC on a Chiral Stationary Phase
    Xiaomin Li
    Zhengping Chen
    Chunyi Liu
    Jie Tang
    Danlu Xue
    Lihua Cao
    Dong Xu
    Chromatographia, 2017, 80 : 483 - 488
  • [40] Chiral Resolution of Enantiomers of Homocamptothecin Derivatives, Antitumor Topoisomerase I Inhibitors, Using High Performance Liquid Chromatography on Polysaccharide-Based Chiral Stationary Phases
    J.F. Goossens
    C. Foulon
    C. Bailly
    D.C.H. Bigg
    J.P. Bonte
    C. Vaccher
    Chromatographia, 2004, 59 : 305 - 313