A resin gauge for performance testing of X-ray CT and its calibration by multiple orientation measurements

被引:0
|
作者
Watanabe, M. [1 ]
Sato, O. [1 ]
Matsuzaki, K. [1 ]
Telada, S. [1 ]
Watanabe, T. [1 ]
Bitou, Y. [1 ]
Takatsuji, T. [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan NMIJ, AIST Tsukuba Cent 3,1-1-1 Umezono, Tsukuba, Ibaraki 3058560, Japan
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2023年 / 84卷
关键词
Three-dimensional measurement; X-ray computed tomography; Calibration; Reference standard; Gauge; Measurement uncertainty;
D O I
10.1016/j.precisioneng.2023.06.009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An accurate and traceable performance testing of the X-ray computed tomography (XCT) is crucial for the application of the XCT in various industrial fields. For the performance testing of the XCT, we proposed a novel gauge with spheres embedded in a cylindrical resin. The proposed gauge is free from the artifacts caused by the gauge structure, and the spheres can be arranged at any position of the gauge. Additionally, the gauge can be placed with different orientations and it can be produced at an economical price. We verified the feasibility of using the proposed gauge as a reference standard, in terms of the coefficient of thermal expansion and secular change of the resin. Furthermore, we developed the associated calibration method for the gauge through multiple orientation measurements using the XCT. From the results, the proposed gauge can be calibrated with an un-certainty of 1.9 & mu;m when the gauge size is 30 mm.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 37 条
  • [21] Characterising the asphalt concrete fracture performance from X-ray CT Imaging and finite element modelling
    Wang, Hainian
    Wang, Chonghui
    You, Zhanping
    Yang, Xu
    Huang, Zhihan
    INTERNATIONAL JOURNAL OF PAVEMENT ENGINEERING, 2018, 19 (03) : 307 - 318
  • [22] High-performance deep learning segmentation for non-destructive testing of X-ray tomography
    Xu, Cong
    Wei, Gongxiang
    Guan, Yu
    Zhang, Shou
    Wang, Hongwei
    Chen, Xingbang
    Wang, Fuli
    Liu, Huiqiang
    JOURNAL OF MANUFACTURING PROCESSES, 2024, 128 : 98 - 110
  • [23] A novel calibration for L-shell x-ray fluorescence measurements of bone lead concentration using the strontium Kβ/Kα ratio
    Gherase, Mihai R.
    Serna, Blaz
    Kroeker, Sarah
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (04)
  • [24] Energy Calibration of a Silicon-Strip Detector for Photon-Counting Spectral CT by Direct Usage of the X-ray Tube Spectrum
    Liu, Xuejin
    Chen, Han
    Bornefalk, Hans
    Danielsson, Mats
    Karlsson, Staffan
    Persson, Mats
    Xu, Cheng
    Huber, Ben
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 68 - 75
  • [25] Chandrayaan-2 Large Area Soft X-ray Spectrometer (CLASS): Calibration, In-flight performance and first results
    Pillai, Netra S.
    Narendranath, S.
    Vadodariya, K.
    Tadepalli, Srikar P.
    Radhakrishna, V
    Tyagi, Anurag
    Yadav, Reena
    Singh, Brajpal
    Sharan, Vaishali
    Athiray, P. S.
    Sreekumar, P.
    Sankarasubramanian, K.
    Bhatt, Megha
    Sarbadhikari, Amit Basu
    Mithun, N. P. S.
    Vadawale, Santosh
    ICARUS, 2021, 363
  • [26] Detailed calibration of the PI-LCX:1300 high performance single photon counting hard x-ray CCD camera
    洪伟
    温贤伦
    魏来
    朱斌
    吴玉迟
    董克攻
    焦春晔
    伍波
    何颖玲
    张发强
    周维民
    谷渝秋
    Chinese Physics B, 2017, (02) : 338 - 344
  • [27] The effect of storage time and repeated measurements on the elastic properties of isolated porcine aortas using high resolution x-ray CT
    Medynsky, AO
    Holdsworth, DW
    Sherebrin, MH
    Rankin, RN
    Roach, MR
    CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1998, 76 (04) : 451 - 456
  • [28] Evaluating conventional and deep learning segmentation for fast X-ray CT porosity measurements of polymer laser sintered AM parts
    Bellens, Simon
    Probst, Gabriel M.
    Janssens, Michel
    Vandewalle, Patrick
    Dewulf, Wim
    POLYMER TESTING, 2022, 110
  • [29] Detailed calibration of the PI-LCX: 1300 high performance single photon counting hard x-ray CCD camera
    Hong, Wei
    Wen, Xian-Lun
    Wei, Lai
    Zhu, Bin
    Wu, Yu-Chi
    Dong, Ke-Gong
    Jiao, Chun-Ye
    Wu, Bo
    He, Ying-Ling
    Zhang, Fa-Qiang
    Zhou, Wei-Min
    Gu, Yu-Qiu
    CHINESE PHYSICS B, 2017, 26 (02)
  • [30] The Optics and Alignment of the Divergent Beam Laboratory X-ray Powder Diffractometer and its Calibration Using NIST Standard Reference Materials
    Cline, James P.
    Mendenhall, Marcus H.
    Black, David
    Windover, Donald
    Henins, Albert
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2015, 120 : 173 - 222