A resin gauge for performance testing of X-ray CT and its calibration by multiple orientation measurements

被引:0
|
作者
Watanabe, M. [1 ]
Sato, O. [1 ]
Matsuzaki, K. [1 ]
Telada, S. [1 ]
Watanabe, T. [1 ]
Bitou, Y. [1 ]
Takatsuji, T. [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan NMIJ, AIST Tsukuba Cent 3,1-1-1 Umezono, Tsukuba, Ibaraki 3058560, Japan
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2023年 / 84卷
关键词
Three-dimensional measurement; X-ray computed tomography; Calibration; Reference standard; Gauge; Measurement uncertainty;
D O I
10.1016/j.precisioneng.2023.06.009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An accurate and traceable performance testing of the X-ray computed tomography (XCT) is crucial for the application of the XCT in various industrial fields. For the performance testing of the XCT, we proposed a novel gauge with spheres embedded in a cylindrical resin. The proposed gauge is free from the artifacts caused by the gauge structure, and the spheres can be arranged at any position of the gauge. Additionally, the gauge can be placed with different orientations and it can be produced at an economical price. We verified the feasibility of using the proposed gauge as a reference standard, in terms of the coefficient of thermal expansion and secular change of the resin. Furthermore, we developed the associated calibration method for the gauge through multiple orientation measurements using the XCT. From the results, the proposed gauge can be calibrated with an un-certainty of 1.9 & mu;m when the gauge size is 30 mm.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 37 条
  • [1] Research on calibration model of X-ray thickness gauge
    Xu, G.-D., 1600, Atomic Energy Press (48): : 925 - 929
  • [2] A spectral calibration technique for x-ray CT
    Johnston, Samuel M.
    Badea, Cristian T.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [3] X-ray image calibration and its application to clinical orthopedics
    Schumann, Steffen
    Thelen, Benedikt
    Ballestra, Steven
    Nolte, Lutz-P.
    Buechler, Philippe
    Zheng, Guoyan
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (07) : 968 - 974
  • [4] Performance testing of dimensional X-ray computed tomography systems
    Zwanenburg, E. A.
    Williams, M. A.
    Warnett, J. M.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2022, 77 : 179 - 193
  • [5] Dimensional metrology with X-ray CT: A comparison with CMM measurements on internal features and compliant structures
    Villarraga-Gomez, Herminso
    Lee, ChaBum
    Smith, Stuart T.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2018, 51 : 291 - 307
  • [6] PERFORMANCE EVALUATION OF DIAGNOSTIC RADIOLOGY DOSIMETERS IN CLINICAL AND CALIBRATION X-RAY BEAMS
    Hourdakis, Costantine John
    Boziari, Argyro
    Manetou, Aggeliki
    HEALTH PHYSICS, 2010, 98 (05): : 704 - 716
  • [7] Prediction of porosity characteristics of aluminium castings based on X-ray CT measurements
    Weidt, M.
    Hardin, R. A.
    Garb, C.
    Rosc, J.
    Brunner, R.
    Beckermann, C.
    INTERNATIONAL JOURNAL OF CAST METALS RESEARCH, 2018, 31 (05) : 289 - 307
  • [8] X-ray Mirror Assembly for the X-Ray Imaging and Spectroscopy Mission (XRISM): comparison between ground-calibration measurements and raytracing simulations
    Boissay-Malaquin, Rozenn
    Hayashi, Takayuki
    Tamura, Keisuke
    Okajima, Takashi
    Yagoub, Tahir
    Eckart, Megan E.
    Hell, Natalie
    Leutenegger, Maurice
    Loewenstein, Michael
    Sato, Toshiki
    SPACE TELESCOPES AND INSTRUMENTATION 2024: ULTRAVIOLET TO GAMMA RAY, PT 1, 2024, 13093
  • [9] Ground Calibration of the X-ray Mirror Assembly for the X-Ray Imaging and Spectroscopy Mission (XRISM) III - Performance variation across the aperture
    Hayashi, Takayuki
    Boissay-Malaquin, Rozenn
    Tamura, Keisuke
    Okajima, Takashi
    Sato, Toshiki
    Olsen, Lawrence G.
    Koenecke, Richard
    Lara, Wilson
    Bleier, Leor
    Leutenegger, Maurice A.
    Eckart, Megan E.
    Yaqoob, Tahir
    Chiao, Meng
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [10] Exploiting multiple view geometry in X-ray testing: Part I, theory
    Mery, D
    MATERIALS EVALUATION, 2003, 61 (11) : 1226 - 1233