Transcatheter Aortic Valve Implantation: Addressing the Subsequent Risk of Permanent Pacemaker Implantation

被引:6
作者
Lauten, Philipp [1 ]
Costello-Boerrigter, Lisa C. [1 ]
Goebel, Bjoern [1 ]
Gonzalez-Lopez, David [1 ]
Schreiber, Matthias [1 ]
Kuntze, Thomas [1 ]
Al Jassem, Mahmoud [1 ]
Lapp, Harald [1 ]
机构
[1] Zent Klin Bad Berka, Heart Ctr, Dept Cardiol, Robert Koch Allee 9, D-99437 Bad Berka, Germany
关键词
TAVI; pacemaker; conduction disturbances; implantation depth; PPI; BUNDLE-BRANCH BLOCK; CONDUCTION DISTURBANCES; CLINICAL-OUTCOMES; REPLACEMENT; PREDICTORS; IMPACT; NEED; ABNORMALITIES; STENOSIS; TAVI;
D O I
10.3390/jcdd10060230
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation (TAVI) is now a commonly used therapy in patients with severe aortic stenosis, even in those patients at low surgical risk. The indications for TAVI have broadened as the therapy has proven to be safe and effective. Most challenges associated with TAVI after its initial introduction have been impressively reduced; however, the possible need for post-TAVI permanent pacemaker implantation (PPI) secondary to conduction disturbances continues to be on the radar. Conduction abnormalities post-TAVI are always of concern given that the aortic valve lies in close proximity to critical components of the cardiac conduction system. This review will present a summary of noteworthy pre-and post-procedural conduction blocks, the best use of telemetry and ambulatory device monitoring to avoid unnecessary PPI or to recognize the need for late PPI due to delayed high-grade conduction blocks, predictors to identify those patients at greatest risk of requiring PPI, important CT measurements and considerations to optimize TAVI planning, and the utility of the MInimizing Depth According to the membranous Septum (MIDAS) technique and the cusp-overlap technique. It is stressed that careful membranous septal (MS) length measurement by MDCT during pre-TAVI planning is necessary to establish the optimal implantation depth before the procedure to reduce the risk of compression of the MS and consequent damage to the cardiac conduction system.
引用
收藏
页数:19
相关论文
共 50 条
[21]   Predictors for the risk of permanent pacemaker implantation after transcatheter aortic valve replacement: A systematic review and meta-analysis [J].
Wang, Tongyu ;
Ou, Aixin ;
Xia, Ping ;
Tian, Jiahu ;
Wang, Hongchang ;
Cheng, Zeyi .
JOURNAL OF CARDIAC SURGERY, 2022, 37 (02) :377-405
[22]   Short-term pacemaker dependency after transcatheter aortic valve implantation [J].
Schernthaner, Christiana ;
Kraus, Johannes ;
Danmayr, Franz ;
Hammerer, Matthias ;
Schneider, Jens ;
Hoppe, Uta C. ;
Strohmer, Bernhard .
WIENER KLINISCHE WOCHENSCHRIFT, 2016, 128 (5-6) :198-203
[23]   Leadless pacemaker with transcatheter aortic valve implantation: A single-center experience [J].
Gao, Feng ;
Kherallah, Riyad ;
Koetting, Mackenzie ;
Simpson, Leo ;
Seger, John ;
Koneru, Srikanth ;
Coselli, Joseph ;
Preventza, Ourania ;
Orozco-Sevilla, Vicente ;
Manon, Nastasya ;
Silva, Guilherme, V .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (07) :615-622
[24]   Prognostic impact of permanent pacemaker implantation after transcatheter aortic valve replacement [J].
Sharobeem, Sam ;
Boulmier, Dominique ;
Leurent, Guillaume ;
Bedossa, Marc ;
Leclercq, Christophe ;
Mabo, Philippe ;
Martins, Raphael P. ;
Tomasi, Jacques ;
Verhoye, Jean-Philippe ;
Donal, Erwan ;
Sost, Gwenaelle ;
Le Guellec, Marielle ;
Le Breton, Herve ;
Auffret, Vincent .
HEART RHYTHM, 2022, 19 (07) :1124-1132
[25]   A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement [J].
Qi, Yiming ;
Lin, Xiaolei ;
Pan, Wenzhi ;
Zhang, Xiaochun ;
Ding, Yuefan ;
Chen, Shasha ;
Zhang, Lei ;
Zhou, Daxin ;
Ge, Junbo .
EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
[26]   Correlation of tricuspid regurgitation and new pacemaker implantation in patients undergoing transcatheter aortic valve implantation [J].
Schewel, Dimitry ;
Schewel, Jury ;
Schlueter, Michael ;
Kreidel, Felix ;
Schmidt, Tobias ;
Schmoeckel, Michael ;
Elsaesser, Albrecht ;
Kuck, Karl-Heinz ;
Frerker, Christian .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 261 :37-41
[27]   Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis [J].
Droppa, Michal ;
Rudolph, Tanja K. ;
Baan, Jan ;
Nielsen, Niels-Erik ;
Baumgartner, Helmut ;
Vendrik, Jeroen ;
Froehlich, Maren ;
Borst, Oliver ;
Woehrle, Jochen ;
Gawaz, Meinrad ;
Potratz, Paul ;
Hack, Luis P. ;
Mauri, Victor ;
Baranowski, Jacek ;
Bramlage, Peter ;
Kurucova, Jana ;
Thoenes, Martin ;
Rottbauer, Wolfgang ;
Geisler, Tobias .
HEART AND VESSELS, 2020, 35 (12) :1735-1745
[28]   Do Women Require Less Permanent Pacemaker After Transcatheter Aortic Valve Implantation? A Meta-Analysis and Meta-Regression [J].
Ravaux, Justine M. ;
Di Mauro, Michele ;
Vernooy, Kevin ;
Van't Hof, Arnoud W. ;
Veenstra, Leo ;
Kats, Suzanne ;
Maessen, Jos G. ;
Lorusso, Roberto .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (07)
[29]   Influence of permanent pacemaker implantation after transcatheter aortic valve implantation with new-generation devices [J].
Gonska, B. ;
Kessler, M. ;
Woehrle, J. ;
Rottbauer, W. ;
Seeger, J. .
NETHERLANDS HEART JOURNAL, 2018, 26 (12) :620-627
[30]   A Two-Step Risk Score for Prediction of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation [J].
Janiszewski, Alexandra ;
Lueg, Julia ;
Schulze, Daniel ;
Juri, Benjamin ;
Morell, Louis ;
Hajduczenia, Maria ;
Hennig, Pierre ;
Erbay, Aslihan ;
Lembcke, Alexander ;
Niehues, Stefan ;
Landmesser, Ulf ;
Stangl, Karl ;
Leistner, David ;
Tscholl, Verena ;
Dreger, Henryk .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2025, 14 (10)