Evaluation of the stiffness of normal cervix and its change with different factors using transvaginal two-dimensional shear wave elastography under strict quality control

被引:3
|
作者
Zhang, Hui-Ping [1 ]
Wu, Jing-Jing [1 ]
Zhang, Wen-Ying [2 ]
Tao, Jiu-Zhi [1 ]
Ma, Cheng-Bin [2 ]
Zhou, Yu-Qing [1 ]
机构
[1] East China Normal Univ, Shanghai Changning Matern & Infant Hlth Hosp, Dept Ultrasound, Shanghai 200050, Peoples R China
[2] East China Normal Univ, Shanghai Changning Matern & Infant Hlth Hosp, Dept Gynecol, Shanghai 200050, Peoples R China
基金
上海市自然科学基金;
关键词
Cervix; Two-dimension; Shear wave elastography; Transvaginal ultrasound; Quality control; ULTRASOUND ELASTOGRAPHY; CARCINOMA;
D O I
10.1186/s12880-023-01020-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe usefulness of transvaginal two-dimensional shear wave elastography (2D SWE) for cervical lesions is still uncertain. This study was to explore the value of transvaginal 2D SWE in the evaluation of the stiffness of normal cervix and its change with different factors under strict quality control (QC).MethodsTwo hundred patients with normal cervix were included in this study and were examined using quantitative 2D SWE to evaluate cervical stiffness and its change with different factors under strict QC.ResultsIntra-observer concordance of transvaginal 2D SWE parameters in midsagittal planes were acceptable with intraclass correlation coefficients higher than 0.5. Transvaginal 2D SWE parameters were significantly higher than the corresponding transabdominal parameters. 2D SWE parameters of internal cervical os were significantly higher than the corresponding parameters of external cervical os in a transvaginal midsagittal plane. 2D SWE parameters of external cervical os increased significantly over 50 years old, while these parameters of internal cervical os didn't change significantly with increasing age. 2D SWE parameters of internal cervical os of horizontal position cervix were significantly higher than those of vertical position cervix. SWE parameters of normal cervix did not change according to different menstrual cycles, parities and human papilloma virus test results.ConclusionsTransvaginal 2D SWE under strict QC could provide quantitative, repeatable and reliable cervical stiffness information. Internal cervical os was stiffer than external cervical os. Menstrual cycles, parities and human papilloma virus test results wouldn't affect cervical stiffness. However, age and cervical positions should be taken into condition while interpreting 2D SWE results of cervical stiffness.
引用
收藏
页数:9
相关论文
共 8 条
  • [1] Evaluation of the stiffness of normal cervix and its change with different factors using transvaginal two-dimensional shear wave elastography under strict quality control
    Hui-Ping Zhang
    Jing-Jing Wu
    Wen-Ying Zhang
    Jiu-Zhi Tao
    Cheng-Bin Ma
    Yu-Qing Zhou
    BMC Medical Imaging, 23
  • [2] Effects of Confounding Factors on Liver Stiffness in Two-Dimensional Shear Wave Elastography in Beagle Dogs
    Cha, Jinwoo
    Kim, Jayon
    Ko, Jaeeun
    Kim, Jaehwan
    Eom, Kidong
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [3] Evaluation of liver and spleen stiffness of healthy dogs by use of two-dimensional shear wave elastography
    Tamura, Masahiro
    Ohta, Hiroshi
    Nisa, Khoirun
    Osuga, Tatsuyuki
    Sasaki, Noboru
    Morishita, Keitaro
    Takiguchi, Mitsuyoshi
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2019, 80 (04) : 378 - 384
  • [4] Evaluation of liver stiffness in a population of client owned healthy dogs using two-dimensional shear wave elastography: intraobserver reliability
    Toom, M.
    Saunders, J. H.
    Duchateau, L.
    De Rooster, H.
    Devriendt, N.
    Stock, E.
    VLAAMS DIERGENEESKUNDIG TIJDSCHRIFT, 2023, 92 (02): : 66 - 74
  • [5] Inter-platform reproducibility of liver stiffness measured with two different point shear wave elastography techniques and 2-dimensional shear wave elastography using the comb-push technique
    Ryu, Hwaseong
    Ahn, Su Joa
    Yoon, Jeong Hee
    Lee, Jeong Min
    ULTRASONOGRAPHY, 2019, 38 (04) : 345 - 354
  • [6] Feasibility of liver stiffness measured using two-dimensional shear wave elastography in assessing preoperative liver function for patients with hepatocellular carcinoma
    Long, Haiyi
    Xu, Wenxin
    Zhong, Xian
    Chen, Zebin
    Su, Liya
    Duan, Yu
    Shi, Yifan
    Xie, Xiaoyan
    Lin, Manxia
    ABDOMINAL RADIOLOGY, 2022, 47 (02) : 664 - 671
  • [7] Feasibility of liver stiffness measured using two-dimensional shear wave elastography in assessing preoperative liver function for patients with hepatocellular carcinoma
    Haiyi Long
    Wenxin Xu
    Xian Zhong
    Zebin Chen
    Liya Su
    Yu Duan
    Yifan Shi
    Xiaoyan Xie
    Manxia Lin
    Abdominal Radiology, 2022, 47 : 664 - 671
  • [8] Evaluation of liver fibrosis in HCV-infected patients using two-dimensional shear-wave elastography (2D-SWE) before and after antiviral treatment
    Inglot, Marcin
    Pozowski, Patryk
    Misiak, Paula
    Fleischer-Stepniewska, Katarzyna
    Lewandowski, Lukasz
    Bilski, Mateusz
    Zaleska-Dorobisz, Urszula
    JOURNAL OF ULTRASONOGRAPHY, 2024, 24 (99) : 7 - 10