A paired emitter-detector diode-based photometer for the determination of sodium hypochlorite adulteration in milk

被引:7
作者
Bastan, Narges [1 ]
Ahmadi, Mazaher [1 ]
Madrakian, Tayyebeh [1 ]
Afkhami, Abbas [1 ]
Khalili, Sina [1 ]
Majidi, Mohsen [1 ]
Moradi, Mohammadreza [2 ]
机构
[1] Bu Ali Sina Univ, Fac Chem, Hamadan 6517838695, Iran
[2] Hamadan Univ Med Sci, Res Ctr Mol Med, Hamadan, Iran
关键词
ABSORPTION DETECTION; TRANSITION-METALS; CHLORINE; SENSITIVITY; PERSISTENCE; OXIDATION; DIETARY;
D O I
10.1038/s41598-023-33527-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper reports on developing a low cost but efficient paired emitter-detector diode (PEDD)-based photometer. The photometer consists of a white light-emitting diode (LED) as the emitter diode, an RGB LED as the detector diode, and a multimeter for recoding the signal. The developed PEDD-based photometer was utilized for the determination of liquid bleach adulteration in cow milk samples. N,N-Diethyl-p-phenylenediamine sulfate aqueous solution of pH 6 was used as a probe to monitor the presence of residual active chlorine in milk. The results showed that the developed method could be used to determine sodium hypochlorite in the concentration range of 0.5 to 20.0 ppm Cl-2 with 0.14 and 0.46 ppm Cl-2 limit of detection and limit of quantification, respectively. The intraday and interday precisions of the method at two concentration levels of 5.5 and 13.7 ppm Cl-2 were 1.04% and 0.52%, and 1.81% and 1.02%, respectively. The recoveries of 114.2% and 106.9% were obtained for 5.5 and 13.7 ppm Cl-2 concentrations levels, respectively. Real sample analyzes results showed that "maybe" liquid bleach adulteration in milk is the case for local distributors of raw milk.
引用
收藏
页数:9
相关论文
共 53 条
[41]   In Situ Determination of Urea in Milk Employing a Portable and Low-Cost LED Photometer [J].
Suarez, Willian Toito ;
de Alvarenga Junior, Benedito Roberto ;
Krambeck Franco, Mathews de Oliveira ;
Gabriel, Wesley Lira ;
de Oliveira, Denilson Mendes ;
dos Santos, Vagner Bezerra .
FOOD ANALYTICAL METHODS, 2018, 11 (04) :1149-1154
[42]   Long path-length axial absorption detection in photonic crystal fiber [J].
Sun, Yi ;
Yu, X. ;
Nguyen, Nam Trung ;
Shum, P. ;
Kwok, Yien Chian .
ANALYTICAL CHEMISTRY, 2008, 80 (11) :4220-4224
[43]   Rapid screening for detection and differentiation of detergent powder adulteration in infant milk formula by LC-MS [J].
Tay, Manjun ;
Fang, Guihua ;
Chia, Poh Ling ;
Li, Sam Fong Yau .
FORENSIC SCIENCE INTERNATIONAL, 2013, 232 (1-3) :32-39
[44]  
Thomas S., 2021, EBOOKZ
[45]   The race for the ideal single-photon source is on [J].
Thomas, Sarah ;
Senellart, Pascale .
NATURE NANOTECHNOLOGY, 2021, 16 (04) :367-368
[46]   Paired emitter-detector diode detection with dual wavelength monitoring for enhanced sensitivity to transition metals in ion chromatography with post-column reaction [J].
Toole, Martina O' ;
Barron, Leon ;
Shepherd, Roderick ;
Paull, Brett ;
Nesterenko, Pavel ;
Diamond, Dermot .
ANALYST, 2009, 134 (01) :124-130
[47]   Simplified paired-emitter-detector-diodes-based photometry with improved sensitivity [J].
Tymecki, Lukasz ;
Koncki, Robert .
ANALYTICA CHIMICA ACTA, 2009, 639 (1-2) :73-77
[48]   Use of universal 3D-Printed smartphone spectrophotometer to develop a time-based analysis for hypochlorite [J].
Vidal, Ezequiel ;
Lorenzetti, Anabela S. ;
Garcia, Carlos D. ;
Domini, Claudia E. .
ANALYTICA CHIMICA ACTA, 2021, 1151
[49]  
Vogel A. I., 2000, VOGELS TXB QUANTITAT
[50]  
Wong N.P., 2012, Fundamentals of Dairy Chemistry