Comminuted Olecranon Fractures (Mayo IIB): Is Dynamic Tension Band Wiring Enough?

被引:1
作者
Esper, Garrett W. [1 ]
Herbosa, Christopher G. [1 ]
Moses, Michael J. [1 ]
Egol, Kenneth A. [1 ,2 ]
机构
[1] NYU, NYU Langone Hlth, Langone Orthoped Hosp, Dept Orthoped Surg, New York, NY USA
[2] NYU, Grossman Sch Med, Div Orthoped Trauma, Dept Orthoped Surg, 301 E 17th St,14th Floor, New York, NY 10003 USA
关键词
elbow; olecranon; fracture; fixation; impaction; comminuted; tension band wiring; PLATE FIXATION;
D O I
10.1097/BOT.0000000000002474
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives:To compare the efficacy and outcomes of dynamic tension band wiring (TBW) and plate and screw (PS) fixation of comminuted (Mayo Type IIB) olecranon fractures.Design:Retrospective cohort.Setting:Academic medical center.Patients/Participants:Forty-one patients with Mayo type IIB (OTA/AO 2U1C) olecranon fractures were involved in the study.Intervention:Patients with tensile Mayo type IIB olecranon fractures between August 2012 and November 2020 treated by a single surgeon with either TBW or PS fixation were reviewed for demographics, radiographic/surgical details, and clinical/functional outcomes. Descriptive fracture data included proximal olecranon fragment size and the presence of joint impaction at surgery.Main Outcome Measurements:The main outcome measurements were Mayo Elbow Performance Score, elbow range of motion, patient-reported pain, and complications.Results:The mean follow-up was 38 months. Fractures healed for all patients in both groups. No differences in clinical outcomes, functional outcomes, elbow range of motion, or complications were seen between fixation groups. There was no difference in proximal fragment size between the 2 groups. Fractures with articular impaction requiring elevation and grafting demonstrated no difference in clinical or functional outcomes when compared with those that did not have any impaction. However, patients with impacted articular fractures treated with TBW had a higher rate of implant removal (25% vs. 0%, P = 0.05) when compared with those treated with PS.Conclusions:Comminuted Mayo IIB olecranon fractures are amenable to TBW or plate construct, with similar clinical and functional outcomes. The presence of articular impaction is associated with a greater need for implant removal.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [31] Treatment of Sagittal Split Olecranon Fractures Using Dorsal Plates Combined With Tension Band Wiring or Cerclage Wires
    Kiyak, Gorkem
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2019, 20 (03) : 75 - 79
  • [32] Olecranon tension plating or olecranon tension band wiring? A comparative biomechanical study
    Dominik Gruszka
    Charlotte Arand
    Tobias Nowak
    Sven-Oliver Dietz
    Daniel Wagner
    Pol Rommens
    International Orthopaedics, 2015, 39 : 955 - 960
  • [33] Olecranon fractures: A biomechanical comparison of three tension band wiring fixation methods on bone models
    Calisal, Emre
    Ugur, Levent
    JOURNAL OF ORTHOPAEDIC SURGERY, 2023, 31 (03)
  • [34] The effect of Ding's screws and tension band wiring for treatment of olecranon fractures: a biomechanical study
    Zhao, Yong
    Tian, Hongbo
    Yin, Nuo
    Du, Li
    Pan, Mingmang
    Ding, Liang
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [35] Outcomes of olecranon fractures in adolescents: comparison of tension band wiring and Herbert screw fixations
    Yang, Weiwei
    Zhang, Xintao
    Sun, Dong
    Jin, Shaobin
    Chen, Junfei
    Li, Yang
    FRONTIERS IN PEDIATRICS, 2024, 11
  • [36] The effect of ding's screw and tension band wiring for treatment of olecranon fractures: a finite element study
    Yin, Nuo
    Pan, Mingmang
    Li, Chenglei
    Du, Li
    Ding, Liang
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [37] Tension Band Wiring Provides Excellent Patient-Reported Long-Term Results for Both Comminuted and Simple Displaced Olecranon Fractures
    Terstappen, Afra L. E.
    Joosse, Pieter
    van Dijke, Cornelis F.
    Mirck, Boj
    van den Brand, Johan G. H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (07) : E239 - E244
  • [38] A novel technique of using a miniature plate in combination with tension band wiring to treat comminuted patellar fractures
    Gao, Song
    Liu, Xuqiang
    Zhang, Fengtian
    Gao, Tian
    Zhang, Zhihong
    Dai, Min
    MEDICINE, 2018, 97 (15)
  • [39] Polydimethylsiloxane pressure sensors for force analysis in tension band wiring of the olecranon
    Zens, Martin
    Goldschmidtboeing, Frank
    Wagner, Ferdinand
    Reising, Kilian
    Suedkamp, Norbert P.
    Woias, Peter
    TECHNOLOGY AND HEALTH CARE, 2016, 24 (06) : 909 - 917
  • [40] Malpositioned olecranon fracture tension-band wiring results in proximal radioulnar synostosis
    Willinger, Lukas
    Lucke, Martin
    Croenlein, Moritz
    Sandmann, Gunther H.
    Biberthaler, Peter
    Siebenlist, Sebastian
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2015, 20