Comminuted Olecranon Fractures (Mayo IIB): Is Dynamic Tension Band Wiring Enough?

被引:1
作者
Esper, Garrett W. [1 ]
Herbosa, Christopher G. [1 ]
Moses, Michael J. [1 ]
Egol, Kenneth A. [1 ,2 ]
机构
[1] NYU, NYU Langone Hlth, Langone Orthoped Hosp, Dept Orthoped Surg, New York, NY USA
[2] NYU, Grossman Sch Med, Div Orthoped Trauma, Dept Orthoped Surg, 301 E 17th St,14th Floor, New York, NY 10003 USA
关键词
elbow; olecranon; fracture; fixation; impaction; comminuted; tension band wiring; PLATE FIXATION;
D O I
10.1097/BOT.0000000000002474
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives:To compare the efficacy and outcomes of dynamic tension band wiring (TBW) and plate and screw (PS) fixation of comminuted (Mayo Type IIB) olecranon fractures.Design:Retrospective cohort.Setting:Academic medical center.Patients/Participants:Forty-one patients with Mayo type IIB (OTA/AO 2U1C) olecranon fractures were involved in the study.Intervention:Patients with tensile Mayo type IIB olecranon fractures between August 2012 and November 2020 treated by a single surgeon with either TBW or PS fixation were reviewed for demographics, radiographic/surgical details, and clinical/functional outcomes. Descriptive fracture data included proximal olecranon fragment size and the presence of joint impaction at surgery.Main Outcome Measurements:The main outcome measurements were Mayo Elbow Performance Score, elbow range of motion, patient-reported pain, and complications.Results:The mean follow-up was 38 months. Fractures healed for all patients in both groups. No differences in clinical outcomes, functional outcomes, elbow range of motion, or complications were seen between fixation groups. There was no difference in proximal fragment size between the 2 groups. Fractures with articular impaction requiring elevation and grafting demonstrated no difference in clinical or functional outcomes when compared with those that did not have any impaction. However, patients with impacted articular fractures treated with TBW had a higher rate of implant removal (25% vs. 0%, P = 0.05) when compared with those treated with PS.Conclusions:Comminuted Mayo IIB olecranon fractures are amenable to TBW or plate construct, with similar clinical and functional outcomes. The presence of articular impaction is associated with a greater need for implant removal.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [21] Olecranon tension plating or olecranon tension band wiring? A comparative biomechanical study
    Gruszka, Dominik
    Arand, Charlotte
    Nowak, Tobias
    Dietz, Sven-Oliver
    Wagner, Daniel
    Rommens, Pol
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (05) : 955 - 960
  • [22] Stabilization of Olecranon Fractures by Tension Band Wiring or Plate Osteosynthesis: A Retrospective Study of 41 Cases
    Fournet, Alexandre
    Boursier, Jean-Francois
    Corbeau, Solene
    Decambron, Adeline
    Viateau, Veronique
    Fayolle, Pascal
    Bedu, Anne-Sophie
    Leperlier, Dimitri
    Manassero, Mathieu
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2018, 31 (01) : 53 - 61
  • [23] Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures
    Midtgaard, Kaare Sourin
    Soreide, Endre
    Brattgjerd, Jan Egil
    Moatshe, Gilbert
    Madsen, Jan Erik
    Flugsrud, Gunnar B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (06) : 1242 - 1248
  • [24] Tension band wiring of the olecranon: Is it really a dynamic principle of osteosynthesis?
    Brink, P. R. G.
    Windolf, M.
    de Boer, P.
    Brianza, S.
    Braunstein, V.
    Schwieger, K.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 518 - 522
  • [25] Functional Outcomes Following Plating or Tension Band Wiring of Olecranon Fractures
    Nadim Aslam
    Sunil Nair
    George Ampat
    Keith Willett
    European Journal of Trauma, 2003, 29 (5): : 273 - 277
  • [26] Miniplate Augmented Tension-Band Wiring for Comminuted Patella Fractures
    Cho, Jae-Woo
    Kent, William T.
    Cho, Won-Tae
    Kim, Jin-Kak
    Moon, Ki-Ho
    Yeo, Do-Hyun
    Kim, Beom-Soo
    Oh, Chang-Wug
    Oh, Jong-Keon
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (04) : E143 - E150
  • [27] Tension Band Wiring for Olecranon Fractures: Relative Stability of Kirschner Wires in Various Configurations
    Huang, Tsan-Wen
    Wu, Chi-Chuan
    Fan, Kuo-Feng
    Tseng, I-Chuan
    Lee, Po-Cheng
    Chou, Ying-Chao
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (01): : 173 - 176
  • [28] Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones
    Dominik Gruszka
    Charlotte Arand
    Julia Greenfield
    Tobias E. Nowak
    Raphael Kuechle
    Sebastian Kuhn
    Pol M. Rommens
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1651 - 1658
  • [29] Factors influencing K-wire migration in tension-band wiring of olecranon fractures
    Saeed, Zubair M.
    Trickett, Ryan W.
    Yewlett, Alun D.
    Matthews, Timothy J. W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (08) : 1181 - 1186
  • [30] Treatment of Sagittal Split Olecranon Fractures Using Dorsal Plates Combined With Tension Band Wiring or Cerclage Wires
    Kiyak, Gorkem
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2019, 20 (03) : 75 - 79