A fluorogenic micrococcal nuclease-based probe for fast detection and optical imaging of Staphylococcus aureus in prosthetic joint and fracture-related infections

被引:2
|
作者
Schoenmakers, Jorrit W. A. [1 ,2 ]
Lopez-Alvarez, Marina [1 ]
Ijpma, Frank F. A. [3 ]
Wouthuyzen-Bakker, Marjan [1 ]
McNamara II, James O. [4 ]
van Oosten, Marleen [1 ]
Jutte, Paul C. [2 ]
van Dijl, Jan Maarten [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen UMCG, Dept Med Microbiol & Infect Prevent, Hanzepl 1, NL-9700RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen UMCG, Dept Orthopaed, Groningen, Netherlands
[3] Univ Groningen, UMCG, Div Trauma Surg, Dept Surg, Groningen, Netherlands
[4] Nuclease Probe Technol Inc, Lowell, MA USA
关键词
Infection imaging; Optical probe; Orthopedic infection; Periprosthetic joint infection; Fracture-related infection; Staphylococcus aureus; Micrococcal nuclease;
D O I
10.1007/s00259-023-06499-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Staphylococcus aureus is the most common and impactful multi-drug resistant pathogen implicated in (periprosthetic) joint infections (PJI) and fracture-related infections (FRI). Therefore, the present proof-of-principle study was aimed at the rapid detection of S. aureus in synovial fluids and biofilms on extracted osteosynthesis materials through bacteria-targeted fluorescence imaging with the 'smart-activatable' DNA-based AttoPolyT probe. This fluorogenic oligonucleotide probe yields large fluorescence increases upon cleavage by micrococcal nuclease, an enzyme secreted by S. aureus. Methods Synovial fluids from patients with suspected PJI and extracted osteosynthesis materials from trauma patients with suspected FRI were inspected for S. aureus nuclease activity with the AttoPolyT probe. Biofilms on osteosynthesis materials were imaged with the AttoPolyT probe and a vancomycin-IRDye800CW conjugate (vanco-800CW) specific for Gram-positive bacteria. Results 38 synovial fluid samples were collected and analyzed. Significantly higher fluorescence levels were measured for S. aureus-positive samples compared to, respectively, other Gram-positive bacterial pathogens (p < 0.0001), Gram-negative bacterial pathogens (p = 0.0038) and non-infected samples (p = 0.0030), allowing a diagnosis of S. aureus-associated PJI within 2 h. Importantly, S. aureus-associated biofilms on extracted osteosynthesis materials from patients with FRI were accurately imaged with the AttoPolyT probe, allowing their correct distinction from biofilms formed by other Gram-positive bacteria detected with vanco-800CW within 15 min. Conclusion The present study highlights the potential clinical value of the AttoPolyT probe for fast and accurate detection of S. aureus infection in synovial fluids and biofilms on extracted osteosynthesis materials.
引用
收藏
页码:2988 / 2997
页数:10
相关论文
共 1 条
  • [1] Staphylococcus aureus Specific FRET Probe-Based Antibacterial Susceptibility Testing (SF-AST) by Detection of Micrococcal Nuclease Activity
    Yi, So Yeon
    Jeong, Jinyoung
    Kim, Kyoon Eon
    Park, Kyoungsook
    Shin, Yong Beom
    ACS INFECTIOUS DISEASES, 2020, 6 (02): : 215 - 223