Multiparametric Renal Magnetic Resonance Imaging for Prediction and Annual Monitoring of the Progression of Chronic Kidney Disease over Two Years

被引:0
|
作者
Buchanan, Charlotte E. [1 ]
Mahmoud, Huda [2 ,3 ]
Cox, Eleanor F. [1 ,4 ,5 ]
Prestwich, Benjamin L. [1 ]
Noble, Rebecca A. [2 ]
Selby, Nicholas M. [2 ]
Taal, Maarten W. [2 ]
Francis, Susan T. [1 ,4 ,5 ]
机构
[1] Univ Nottingham, Sir Peter Mansfield Imaging Ctr, Sch Phys & Astron, Nottingham NG7 2RD, England
[2] Univ Nottingham, Ctr Kidney Res & Innovat, Royal Derby Hosp Campus, Derby DE2 3DT, England
[3] Manor Hosp, Walsall Healthcare NHS Trust, Moat Rd, Walsall WS2 9PS, England
[4] Nottingham Univ Hosp NHS Trust, NIHR Nottingham Biomed Res Ctr, Nottingham NG7 2QW, England
[5] Univ Nottingham, Nottingham NG7 2QW, England
基金
英国医学研究理事会;
关键词
chronic kidney disease; magnetic resonance imaging; multiparametric; progression; monitoring; INTRARENAL OXYGENATION; GFR DECLINE; END-POINT; FIBROSIS; PATHOLOGY; EQUATION; CKD;
D O I
10.3390/jcm12237282
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Multiparametric renal Magnetic Resonance Imaging (MRI) provides a non-invasive method to assess kidney structure and function, but longitudinal studies are limited. Methods: A total of 22 patients with CKD category G3-4 (estimated glomerular filtration rate (eGFR) 15-59 mL/min/1.73 m(2)) were recruited. Annual 3T multiparametric renal MRI scans were performed, comprising total kidney volume (TKV), longitudinal relaxation time (T-1), apparent diffusion coefficient (ADC), Arterial Spin Labelling, and Blood Oxygen Level Dependent relaxation time (T-2*), with 15 patients completing a Year 2 scan. CKD progression over 2 years was defined as eGFR_slope >= -5 mL/min/1.73 m(2)/year. Results: At baseline, T-1 was higher (cortex p = 0.05, medulla p = 0.03) and cortex perfusion lower (p = 0.015) in participants with subsequent progression versus stable eGFR. A significant decrease in TKV and ADC and an increase in cortex T-1 occurred in progressors at Year 1 and Year 2, with a significant decrease in perfusion in progressors only at Year 2. The only decline in the stable group was a reduction in TKV. There was no significant change in cortex or medulla T-2* at Year 1 or Year 2 for progressors or stable participants. Conclusion: Lower renal cortex perfusion and higher T-1 in the cortex and medulla may predict CKD progression, while renal cortex T-1, TKV, and ADC may be useful to monitor progression. This study provides pilot data for future large-scale studies.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Quantitative magnetic resonance imaging of chronic kidney disease: an experimental in vivo study using rat chronic kidney disease models
    Kim, Sang Youn
    Kim, Hyeonjin
    Lee, Joongyub
    Jung, Sung Il
    Moon, Min Hoan
    Joo, Kwon Wook
    Cho, Jeong Yeon
    ACTA RADIOLOGICA, 2023, 64 (01) : 404 - 414
  • [12] Multiparametric magnetic resonance imaging predicts clinical outcomes in patients with chronic liver disease
    Pavlides, Michael
    Banerjee, Rajarshi
    Sellwood, Joanne
    Kelly, Catherine J.
    Robson, Matthew D.
    Booth, Jonathan C.
    Collier, Jane
    Neubauer, Stefan
    Barnes, Eleanor
    JOURNAL OF HEPATOLOGY, 2016, 64 (02) : 308 - 315
  • [13] Multiparametric magnetic resonance imaging allows non-invasive functional and structural evaluation of diabetic kidney disease
    Makvandi, Kianoush
    Hockings, Paul D.
    Jensen, Gert
    Unnerstall, Tim
    Leonhardt, Henrik
    Jarl, Lisa, V
    Englund, Camilla
    Francis, Susan
    Sundgren, Anna K.
    Hulthe, Johannes
    Baid-Agrawal, Seema
    CLINICAL KIDNEY JOURNAL, 2022, 15 (07) : 1387 - 1402
  • [14] Magnetic resonance elastography for evaluation of renal parenchyma in chronic kidney disease: a pilot study
    Han, Jun Hee
    Ahn, Jhii-Hyun
    Kim, Jae-Seok
    RADIOLOGIA MEDICA, 2020, 125 (12): : 1209 - 1215
  • [15] Magnetic resonance elastography for evaluation of renal parenchyma in chronic kidney disease: a pilot study
    Jun Hee Han
    Jhii-Hyun Ahn
    Jae-Seok Kim
    La radiologia medica, 2020, 125 : 1209 - 1215
  • [16] Magnetic resonance imaging in the monitoring of disease progression in multiple sclerosis
    Stevenson, VL
    Miller, DH
    MULTIPLE SCLEROSIS JOURNAL, 1999, 5 (04) : 268 - 272
  • [17] Multiparametric magnetic resonance imaging in patients with chronic liver disease: are we there yet?
    Ronot, Maxime
    Vilgrain, Valerie
    LIVER INTERNATIONAL, 2016, 36 (05) : 631 - 633
  • [18] How reliable is renal ultrasound to measure renal length and volume in patients with chronic kidney disease compared with magnetic resonance imaging?
    Braconnier, Philippe
    Piskunowicz, Maciej
    Vakilzadeh, Nima
    Mueller, Marie-Eve
    Zuercher, Emilie
    Burnier, Michel
    Pruijm, Menno
    ACTA RADIOLOGICA, 2020, 61 (01) : 117 - 127
  • [19] Evaluation of the parenchymal distribution of renal steatosis in chronic kidney disease using chemical shift magnetic resonance imaging
    Aydin, Hueseyin
    Aydin, Hasan
    Karaibrahimoglu, Adnan
    Afsar, Baris
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2024, 33 (05): : 455 - 462
  • [20] Prediction of chronic kidney disease stages by renal ultrasound imaging
    Chen, Chi-Jim
    Pai, Tun-Wen
    Hsu, Hui-Huang
    Lee, Chien-Hung
    Chen, Kuo-Su
    Chen, Yung-Chih
    ENTERPRISE INFORMATION SYSTEMS, 2020, 14 (02) : 178 - 195