A rapid multiplex loop-mediated isothermal amplification (mLAMP) assay for detection of Entamoeba histolytica and Giardia duodenalis

被引:1
|
作者
Mewara, Abhishek [1 ]
Khunger, Sandhya [1 ,2 ]
Sharma, Chayan [1 ]
Krishnamoorthi, Sivanantham [3 ]
Singh, Shreya [1 ]
Yadav, Rakesh [4 ]
Khurana, Sumeeta [1 ]
Sehgal, Rakesh [1 ]
机构
[1] Postgrad Inst Med Educ & Res PGIMER, Dept Med Parasitol, Chandigarh 160012, India
[2] Shree Guru Gobind Singh Tricentenary Univ, Dept Microbiol FAHS, Gurgaon 122505, India
[3] All India Inst Med Sci AIIMS, Dept Microbiol, Bathinda 151001, India
[4] Postgrad Inst Med Educ & Res PGIMER, Dept Med Microbiol, Chandigarh 160012, India
关键词
multiplex LAMP; NAAT; Giardia duodenalis; Entamoeba histolytica; CRYPTOSPORIDIUM SPP; FECAL SAMPLES; LAMBLIA; PCR; INDIA; LAMP;
D O I
10.1093/lambio/ovad114
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We developed a rapid multiplex loop-mediated isothermal amplification (mLAMP) assay for two common intestinal parasites-Entamoeba histolytica and Giardia duodenalis, where early detection may be helpful. The mLAMP assay was optimized for the detection of DNA of E. histolytica (18S rRNA gene) and G. duodenalis (Elongation factor 1 alpha gene) from standard strains by using six specific primers FIP (forward inner primer), BIP (backward inner primer), F3 (forward outer primer), B3 (backward outer primer), loopF (forward loop primer), and loopB (backward loop primer) for each gene target. The amplification time was 16-26 min for E. histolytica and 10-15 min for G. duodenalis, and the parasites could be distinguished based on melting-curve analysis for specific annealing temperatures (Tm) of 84 degrees C-86 degrees C and 88 degrees C-90 degrees C for E. histolytica and G. duodenalis, respectively. The analytical sensitivity was one fg, and no cross-reactivity with other intestinal pathogens was observed. Thus, the mLAMP assay could detect and clearly distinguish E. histolytica and G. duodenalis with a rapid turnaround time and excellent analytical sensitivity and specificity.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A Rapid Colorimetric Loop-Mediated Isothermal Amplification Assay for the Detection of Lawsonia intracellularis in Pigs
    Choi, Nag-Jin
    Park, Byoung-Yong
    Park, Chul
    Kim, Young-Jun
    Cho, Ho-Seong
    JOURNAL OF ANIMAL AND VETERINARY ADVANCES, 2012, 11 (22): : 4258 - 4262
  • [32] Development of a loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Beiji nairovirus
    Wang, Yiwen
    Huang, Jing
    Chen, Meiyi
    Jin, Zha
    Liu, Tingting
    Jiang, Xi
    Huang, Rongsheng
    Hu, Kairao
    Wei, Zhengkai
    Liu, Quan
    MICROBIAL PATHOGENESIS, 2025, 199
  • [33] Development of a loop-mediated isothermal amplification for rapid detection of orf virus
    Tsai, Su-Ming
    Chan, Kun-Wei
    Hsu, Wei-Li
    Chang, Tien-Jye
    Wong, Min-Liang
    Wang, Chi-Young
    JOURNAL OF VIROLOGICAL METHODS, 2009, 157 (02) : 200 - 204
  • [34] Rapid and Sensitive Detection of Didymella bryoniae by Visual Loop-Mediated Isothermal Amplification Assay
    Yao, Xiefeng
    Li, Pingfang
    Xu, Jinghua
    Zhang, Man
    Ren, Runsheng
    Liu, Guang
    Yang, Xingping
    FRONTIERS IN MICROBIOLOGY, 2016, 7
  • [35] Development of a loop-mediated isothermal amplification assay for rapid and simple detection of Erysipelothrix rhusiopathiae
    Yamazaki, Y.
    Oba, E.
    Kashiwagi, N.
    Sugita, K.
    Shiiba, K.
    Baba, Y.
    Shimoji, Y.
    Yamazaki, W.
    LETTERS IN APPLIED MICROBIOLOGY, 2014, 58 (04) : 362 - 369
  • [36] Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for the Rapid Detection of Alternaria alternata
    Zhang, Xinyue
    Xu, Guojie
    Tang, Huaqi
    Li, Yanpeng
    Liu, Chunsheng
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (01) : 99 - 103
  • [37] A novel and rapid loop-mediated isothermal amplification assay for the specific detection of Verticillium dahliae
    Moradi, A.
    Almasi, M. A.
    Jafary, H.
    Mercado-Blanco, J.
    JOURNAL OF APPLIED MICROBIOLOGY, 2014, 116 (04) : 942 - 954
  • [38] Detection of Mycobacterium Tuberculosis by Loop-Mediated Isothermal Amplification Assay
    Ahn, Young-Chang
    Nam, Youn-Hyoung
    Park, Su-Min
    Cho, Min-Ho
    Seo, Jae-Won
    Yoon, Il-Kyu
    Park, Yong Hyun
    Jang, Won-Cheoul
    JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2008, 52 (03): : 273 - 280
  • [39] Multiple Endonuclease Restriction Real-Time Loop-Mediated Isothermal Amplification A Novel Analytically Rapid, Sensitive, Multiplex Loop-Mediated Isothermal Amplification Detection Technique
    Wang, Yi
    Wang, Yan
    Lan, Ruiting
    Xu, Huaqing
    Ma, Aijing
    Li, Dongxun
    Dai, Hang
    Yuan, Xuejiao
    Xu, Jianguo
    Ye, Changyun
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2015, 17 (04) : 392 - 401
  • [40] Multiplex Loop-Mediated Isothermal Amplification Coupled Lateral Flow Assay for Point-of-Care Detection of Syphilis
    Priya, Krishnamoorthy
    Saranya, Elangovan
    Kapoor, Ashish
    Ramya, Mohandass
    INDIAN JOURNAL OF MICROBIOLOGY, 2024, 64 (03) : 1246 - 1256