Monte Carlo Modeling of the Siemens® ARTISTE™ 160 Multi-leaf Collimator for IMRT dose verification

被引:0
|
作者
Dayyani, M. [1 ]
Hoseinian-Azghadi, E. [2 ]
Rafat-Motavalli, L. [3 ]
Miri-Hakimabad, H. [3 ]
Tugrul, T. [4 ]
Sobhkhiz-Sabet, L. [5 ]
机构
[1] Reza Radiotherapy & Oncol Ctr, Radiat Oncol Dept, Mashhad, Iran
[2] Reza Radiotherapy & Oncol Ctr, Res & Educ Dept, Mashhad, Iran
[3] Ferdowsi Univ Mashhad, Dept Phys, Fac Sci, Mashhad, Iran
[4] Yuzuncu Yil Univ, Dept Radiat Oncol, Med Fac, Van, Turkiye
[5] Reza Radiotherapy & Oncol Ctr, Dept Med Phys, Mashhad, Iran
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-1801
引用
收藏
页码:S1526 / S1526
页数:1
相关论文
共 50 条
  • [1] A multi-leaf collimator model for accurate IMRT Monte Carlo dose calculation
    Siebers, J
    Keall, P
    Kim, J
    Mohan, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1316 - 1316
  • [2] Modeling a Multi Leaf Collimator for IMRT Monte Carlo Dose Calculations
    Craig, J.
    Mulligan, M.
    Chen, J.
    Wong, E.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [3] Development and verification of a time delivery model for prostate intensity modulated radiotherapy using a Siemens® Artiste™ 160 Multi-leaf Collimator Linac
    Nicola Fourie
    Omer A. Ali
    William I. D. Rae
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 51 - 56
  • [4] Development and verification of a time delivery model for prostate intensity modulated radiotherapy using a Siemens® Artiste™ 160 Multi-leaf Collimator Linac
    Fourie, Nicola
    Ali, Omer A.
    Rae, William I. D.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 51 - 56
  • [5] Development of Monte Carlo Dose Calculation System for a New Dual Layer Multi-Leaf Collimator
    Ishihara, Y.
    Nakamura, M.
    Mizowaki, T.
    Hiraoka, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E164 - E164
  • [6] Motorized multi-leaf collimator for electrons: Measurements with a prototype and Monte Carlo simulations
    Tremblay, H.
    Bouchard, H.
    Mercure, S.
    Robichaud, J.
    Beausoleil, M.
    Charette, M.
    Carrier, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2175 - 2175
  • [7] Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization
    Siebers, JV
    Lauterbach, M
    Keall, PJ
    Mohan, R
    MEDICAL PHYSICS, 2002, 29 (06) : 952 - 959
  • [8] Feasibility of using Geant4 Monte Carlo simulation for IMRT dose calculations for the Novalis Tx with a HD-120 multi-leaf collimator
    Hyunuk Jung
    Jungsuk Shin
    Kwangzoo Chung
    Youngyih Han
    Jinsung Kim
    Doo Ho Choi
    Journal of the Korean Physical Society, 2015, 66 : 1489 - 1494
  • [9] Philips Pinnacle Photon Beam Modeling for Elekta Agility 160 Leaf Multi-Leaf Collimator
    Girard, F.
    Hinse, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Feasibility of using Geant4 Monte Carlo simulation for IMRT dose calculations for the Novalis Tx with a HD-120 multi-leaf collimator
    Jung, Hyunuk
    Shin, Jungsuk
    Chung, Kwangzoo
    Han, Youngyih
    Kim, Jinsung
    Choi, Doo Ho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (10) : 1489 - 1494