Enantiomeric excess determination by quantum cascade laser vibrational circular dichroism - a chemometric approach

被引:0
|
作者
Lendl, Bernhard [1 ]
Hermann, Daniel-Ralph [1 ]
Ramer, Georg [1 ]
Kitzler-Zeiler, Markus [2 ]
机构
[1] TU Wien, Inst Chem Technol & Analyt, Getreidemarkt 9-164 UPA, A-1060 Vienna, Austria
[2] TU Wien, Photon Inst, Gusshausstr 27-29, A-1040 Vienna, Austria
来源
关键词
Vibrational Circular Dichroism; EC-QCL; Balanced detection; Enantiomeric Excess; chemometrics; ridge regression; Lasso; SPECTROSCOPY; REGRESSION;
D O I
10.1117/12.2650526
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Enantiomeric excess, the ratio between two enantiomers, is an important process variable in chiral catalysis. To increase the efficiency of such processes, this parameter needs to be monitored as close to real time as possible and ideally without elaborate sample preparation. Vibrational circular dichroism (VCD) provides chiral information in a pretreatment free and nondestructive manner. Since classical VCD suffers from a low time resolution, quantum cascade laser (QCL) based VCD was introduced to enable studying more dynamic processes. This significantly improved time resolution enables the use of EC-QCL VCD for monitoring the change of EE e.g. in a chemical process or a chemical reaction. In such applications, the classical approach of human interpretation of individual VCD spectra is no longer reasonable. Hence, chemometric evaluation of VCD spectral datasets is required. In this work we compare accuracy and stability of common multivariate regression algorithms for predicting EE from EC-QCL VCD spectra. Besides classical partial-least-squares regression, modified multiple linear regressions and models derived from chemical knowledge were investigated. We found that a combination of introducing chemical knowledge via spectral descriptor and a reduction of multicollinearity by a ridge regression model resulted in the most stable prediction. Additionally, least absolute shrinkage and selection operator ( Lasso) revealed a potential for sensor design involving dedicated QCL arrays focused on a few relevant wavelengths. In summary, a more comprehensive chemometric perspective on QCL-VCD spectra can yield improvements in predictive performance and the shorter measurement times provided by QCL-VCD aid in acquiring datasets of appropriate size.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Enantiomeric Excess Sensitivity to Below One Percent by Using Femtosecond Photoelectron Circular Dichroism
    Kastner, Alexander
    Lux, Christian
    Ring, Tom
    Zuellighoven, Stefanie
    Sarpe, Cristian
    Senftleben, Arne
    Baumert, Thomas
    CHEMPHYSCHEM, 2016, 17 (08) : 1119 - 1122
  • [32] Synthesis of Chiral Labtb and Visualization of Its Enantiomeric Excess by Induced Circular Dichroism Imaging
    Yamada, Teppei
    Eguchi, Toshiki
    Wakiyama, Taro
    Narushima, Tetsuya
    Okamoto, Hiromi
    Kimizuka, Nobuo
    CHEMISTRY-A EUROPEAN JOURNAL, 2019, 25 (27) : 6698 - 6702
  • [33] Determination of enantiomeric purity by simultaneous dual circular dichroism and ultraviolet spectroscopy
    Horvath, P
    Gergely, A
    Noszal, B
    TALANTA, 1997, 44 (08) : 1479 - 1485
  • [34] Determination of the absolute configurations using electronic and vibrational circular dichroism measurements and quantum chemical calculations
    Polavarapu, Prasad L.
    Frelek, Jadwiga
    Woznica, Magdalena
    TETRAHEDRON-ASYMMETRY, 2011, 22 (18-19) : 1720 - 1724
  • [35] Stereodynamic Chemosensor with Selective Circular Dichroism and Fluorescence Readout for in Situ Determination of Absolute Configuration, Enantiomeric Excess, and Concentration of Chiral Compounds
    Bentley, Keith W.
    Wolf, Christian
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (33) : 12200 - 12203
  • [36] Magnetic circular dichroism in Archean atmosphere and asymmetric photolysis of biomolecules: enantiomeric excess of prebiotic sugar
    Sharma, A.
    JOURNAL OF BIOLOGICAL PHYSICS, 2020, 46 (03) : 283 - 295
  • [37] Magnetic circular dichroism in Archean atmosphere and asymmetric photolysis of biomolecules: enantiomeric excess of prebiotic sugar
    A. Sharma
    Journal of Biological Physics, 2020, 46 : 283 - 295
  • [38] Enantiomeric characterization and structure elucidation of LH601A using vibrational circular dichroism spectroscopy
    Shen, Jian
    Magesh, Sadagopan
    Chen, Lin
    Hu, Longqin
    He, Yanan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 192 : 312 - 317
  • [39] Determination of absolute configuration using circular dichroism: Troger's base revisited using vibrational circular dichroism
    Aamouche, A
    Devlin, FJ
    Stephens, PJ
    CHEMICAL COMMUNICATIONS, 1999, (04) : 361 - 362
  • [40] Multidimensional Vibrational Circular Dichroism Apparatus Equipped with Quantum Cascade Laser and Its Use for Investigating Some Peptide Systems Containing D-Amino Acids
    Sato, Hisako
    Shimizu, Masaru
    Watanabe, Keisuke
    Yoshida, Jun
    Kawamura, Izuru
    Koshoubu, Jun
    ANALYTICAL CHEMISTRY, 2021, 93 (05) : 2742 - 2748