Confirmation of Statin and Fibrate Use from Small-Volume Archived Plasma Samples by High-Throughput LC-MS/MS Method

被引:1
|
作者
Kusovschi, Jennifer D. D. [1 ]
Ivanova, Anna A. A. [1 ]
Gardner, Michael S. S. [1 ]
McGarrah III, Robert W. W. [2 ]
Kraus, William E. E. [2 ]
Kuklenyik, Zsuzsanna [1 ]
Pirkle, James L. L. [1 ]
Barr, John R. R. [1 ]
机构
[1] CDCP, Clin Chem Branch, Div Lab Sci, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
[2] Duke Univ, Sch Med, Duke Mol Physiol Inst, Durham, NC 27701 USA
关键词
mass spectrometry; LC-MS/MS; human plasma; medical records; statins; fibrates; cardiovascular disease; LIQUID-CHROMATOGRAPHY; FAMILIAL HYPERCHOLESTEROLEMIA; SIMULTANEOUS QUANTIFICATION; QUANTITATIVE-DETERMINATION; SIMVASTATIN ACID; FENOFIBRIC ACID; ROSUVASTATIN; METABOLITE; ASSAY; GEMFIBROZIL;
D O I
10.3390/ijms24097931
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Designing studies for lipid-metabolism-related biomarker discovery is challenging because of the high prevalence of various statin and fibrate usage for lipid-lowering therapies. When the statin and fibrate use is determined based on self-reports, patient adherence to the prescribed statin dose regimen remains unknown. A potentially more accurate way to verify a patient's medication adherence is by direct analytical measurements. Current analytical methods are prohibitive because of the limited panel of drugs per test and large sample volume requirement that is not available from archived samples. A 4-min-long method was developed for the detection of seven statins and three fibrates using 10 mu L of plasma analyzed via reverse-phase liquid chromatography and tandem mass spectrometry. The method was applied to the analysis of 941 archived plasma samples collected from patients before cardiac catheterization. When statin use was self-reported, statins were detected in 78.6% of the samples. In the case of self-reported atorvastatin use, the agreement with detection was 90.2%. However, when no statin use was reported, 42.4% of the samples had detectable levels of statins, with a similar range of concentrations as the samples from the self-reported statin users. The method is highly applicable in population studies designed for biomarker discovery or diet and lifestyle intervention studies, where the accuracy of statin or fibrate use may strongly affect the statistical evaluation of the biomarker data.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] High-throughput LC-MS quantitation of cell culture metabolites
    Sun, Zhiyuan
    Ji, Qinqin
    Evans, Adam R.
    Lewis, Michael J.
    Mo, Jingjie
    Hu, Ping
    BIOLOGICALS, 2019, 61 : 44 - 51
  • [42] Derivatization-based High-throughput Bioanalysis by LC-MS
    Toshimasa Toyo’Oka
    Analytical Sciences, 2017, 33 : 555 - 564
  • [43] A Novel Analytical Method for the Estimation of Solriamfetol in Plasma Samples by Lc-Ms/Ms
    Ratnakumar, Perina
    Kannappan, N.
    Premkumar, P.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2021, 11 (05): : 129 - 138
  • [44] Validation of LC-MS/MS Method for Monitoring of Upadacitinib in Rat Plasma Samples
    Inturi, Ravikanth
    Raju, Medepalli David
    Rao, Mandava Venkata Basaveswara
    Inturi, Srikanth
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 (02) : 102 - 107
  • [45] An LC-MS/MS Method Development and Validation for the Quantification of Abametapir in Plasma Samples
    Sankar, Palakollu D. S.
    Panigrahi, Naresh
    SEPARATION SCIENCE PLUS, 2025, 8 (01):
  • [46] A high-throughput LC-MS/MS assay for quantification of artesunate and its metabolite dihydroartemisinin in human plasma and saliva
    Birgersson, Sofia
    Ericsson, Therese
    Blank, Antje
    von Hagens, Cornelia
    Ashton, Michael
    Hoffmann, Kurt-Jurgen
    BIOANALYSIS, 2014, 6 (18) : 2357 - 2369
  • [47] High throughput LC-MS/MS method for simultaneous determination of tenofovir, lamivudine and nevirapine in human plasma
    Valluru, Rajani Kumar
    Reddy, Phani Bhushana B.
    Sumanth, Kalyan S.
    Kumar, Praveen, V
    Kilaru, Naveen Babu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 931 : 117 - 126
  • [48] High throughput LC-MS/MS method for simultaneous determination of zidovudine, lamivudine and nevirapine in human plasma
    Kumar, Valluru Rajani
    Reddy, B. Phani Bhushana
    Kumar, B. Ravi
    Sreekanth, K.
    Babu, Kilaru Naveen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 921 : 9 - 14
  • [49] High throughput LC-MS/MS method for simultaneous quantification of lamivudine, stavudine and nevirapine in human plasma
    Mistri, Hiren N.
    Jangid, Arvind G.
    Pudage, Ashutosh
    Gomes, Noel
    Sanyal, Mallika
    Shrivastav, Pranav
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 320 - 332
  • [50] An Automated High-Throughput Sample Preparation Protocol for LC-MS/MS Analysis of Glycopeptides
    Arul, Albert-Baskar
    Park, Jong-Moon
    Lee, Hookeun
    Baek, Jeong-Heum
    Jeon, Jongho
    Ji, Eunhee
    Oh, Jae Won
    Kim, Kwang Pyo
    CURRENT PROTEOMICS, 2016, 13 (01) : 55 - 60