Confirmation of Statin and Fibrate Use from Small-Volume Archived Plasma Samples by High-Throughput LC-MS/MS Method

被引:1
|
作者
Kusovschi, Jennifer D. D. [1 ]
Ivanova, Anna A. A. [1 ]
Gardner, Michael S. S. [1 ]
McGarrah III, Robert W. W. [2 ]
Kraus, William E. E. [2 ]
Kuklenyik, Zsuzsanna [1 ]
Pirkle, James L. L. [1 ]
Barr, John R. R. [1 ]
机构
[1] CDCP, Clin Chem Branch, Div Lab Sci, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
[2] Duke Univ, Sch Med, Duke Mol Physiol Inst, Durham, NC 27701 USA
关键词
mass spectrometry; LC-MS/MS; human plasma; medical records; statins; fibrates; cardiovascular disease; LIQUID-CHROMATOGRAPHY; FAMILIAL HYPERCHOLESTEROLEMIA; SIMULTANEOUS QUANTIFICATION; QUANTITATIVE-DETERMINATION; SIMVASTATIN ACID; FENOFIBRIC ACID; ROSUVASTATIN; METABOLITE; ASSAY; GEMFIBROZIL;
D O I
10.3390/ijms24097931
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Designing studies for lipid-metabolism-related biomarker discovery is challenging because of the high prevalence of various statin and fibrate usage for lipid-lowering therapies. When the statin and fibrate use is determined based on self-reports, patient adherence to the prescribed statin dose regimen remains unknown. A potentially more accurate way to verify a patient's medication adherence is by direct analytical measurements. Current analytical methods are prohibitive because of the limited panel of drugs per test and large sample volume requirement that is not available from archived samples. A 4-min-long method was developed for the detection of seven statins and three fibrates using 10 mu L of plasma analyzed via reverse-phase liquid chromatography and tandem mass spectrometry. The method was applied to the analysis of 941 archived plasma samples collected from patients before cardiac catheterization. When statin use was self-reported, statins were detected in 78.6% of the samples. In the case of self-reported atorvastatin use, the agreement with detection was 90.2%. However, when no statin use was reported, 42.4% of the samples had detectable levels of statins, with a similar range of concentrations as the samples from the self-reported statin users. The method is highly applicable in population studies designed for biomarker discovery or diet and lifestyle intervention studies, where the accuracy of statin or fibrate use may strongly affect the statistical evaluation of the biomarker data.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] High-throughput method for the quantitation of total folate in whole blood using LC-MS/MS
    Owens, Janel E.
    Holstege, Dirk M.
    Clifford, Andrew J.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (09) : 3292 - 3297
  • [22] High-Throughput Fragment Screening by Affinity LC-MS
    Minh-Dao Duong-Thi
    Bergstrom, Maria
    Fex, Tomas
    Isaksson, Roland
    Ohlson, Sten
    JOURNAL OF BIOMOLECULAR SCREENING, 2013, 18 (02) : 160 - 171
  • [23] The development and validation of a high-throughput LC-MS/MS method for the analysis of endogenous β-hydroxy-β-methylbutyrate in human plasma
    Ramachandran, Subramanian
    Ehling, Stefan
    Shreeram, Sathyavageeswaran
    Reddy, Todime M.
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (07)
  • [24] Development and validation of a sensitive and high-throughput LC-MS/MS method for the simultaneous determination of esomeprazole and naproxen in human plasma
    Gopinath, Shanmugam
    Kumar, Ramadass Satiesh
    Shankar, Madhira Bhawani
    Danabal, Palanisamy
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (07) : 894 - 899
  • [25] A high-volume, high-throughput LC-MS therapeutic drug monitoring system
    Zahlsen, K
    Aamo, T
    Zweigenbaum, J
    SPECTROSCOPY, 2005, 20 (06) : 22 - 28
  • [26] Fast and high-throughput LC-MS characterization, and peptide mapping of engineered AAV capsids using LC-MS/MS
    Lam, Anh K.
    Zhang, Junping
    Frabutt, Dylan
    Mulcrone, Patrick L.
    Li, Lei
    Zeng, Lifan
    Herzog, Roland W.
    Xiao, Weidong
    MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT, 2022, 27 : 185 - 194
  • [27] METHOD OF DEVELOPMENT AND VALIDATION OF NIRAPARIB IN PLASMA SAMPLES BY LC-MS/MS
    Anil, Pamarthi
    Rahaman, Sk. Abdul
    Raj, Injety Sundar
    Ravikishore, Saiempu
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2020, : 613 - 618
  • [28] High-throughput protein identification of complex mixtures by LC-MS/MS.
    Patterson, SD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U151 - U151
  • [29] High-throughput LC-MS/MS method with 96-well plate precipitation for the determination of arotinolol and amlodipine in a small volume of rat plasma: Application to a pharmacokinetic interaction study
    Qian, Zheyuan
    Le, Jian
    Chen, Xiujuan
    Li, Shengni
    Song, Hongjie
    Hong, Zhanying
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (03) : 618 - 629
  • [30] Measurement of yunaconitine and crassicauline A in small-volume blood serum samples by LC-MS/MS: Tracing of aconite poisoning in clinical diagnosis
    Chung, Karen Ka-Wing
    Chen, Sammy Pak-Lam
    Ng, Sau-Wah
    Mak, Tony Wing-Lai
    Leung, Kelvin Sze-Yin
    TALANTA, 2012, 97 : 491 - 498