Confirmation of Statin and Fibrate Use from Small-Volume Archived Plasma Samples by High-Throughput LC-MS/MS Method

被引:1
|
作者
Kusovschi, Jennifer D. D. [1 ]
Ivanova, Anna A. A. [1 ]
Gardner, Michael S. S. [1 ]
McGarrah III, Robert W. W. [2 ]
Kraus, William E. E. [2 ]
Kuklenyik, Zsuzsanna [1 ]
Pirkle, James L. L. [1 ]
Barr, John R. R. [1 ]
机构
[1] CDCP, Clin Chem Branch, Div Lab Sci, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
[2] Duke Univ, Sch Med, Duke Mol Physiol Inst, Durham, NC 27701 USA
关键词
mass spectrometry; LC-MS/MS; human plasma; medical records; statins; fibrates; cardiovascular disease; LIQUID-CHROMATOGRAPHY; FAMILIAL HYPERCHOLESTEROLEMIA; SIMULTANEOUS QUANTIFICATION; QUANTITATIVE-DETERMINATION; SIMVASTATIN ACID; FENOFIBRIC ACID; ROSUVASTATIN; METABOLITE; ASSAY; GEMFIBROZIL;
D O I
10.3390/ijms24097931
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Designing studies for lipid-metabolism-related biomarker discovery is challenging because of the high prevalence of various statin and fibrate usage for lipid-lowering therapies. When the statin and fibrate use is determined based on self-reports, patient adherence to the prescribed statin dose regimen remains unknown. A potentially more accurate way to verify a patient's medication adherence is by direct analytical measurements. Current analytical methods are prohibitive because of the limited panel of drugs per test and large sample volume requirement that is not available from archived samples. A 4-min-long method was developed for the detection of seven statins and three fibrates using 10 mu L of plasma analyzed via reverse-phase liquid chromatography and tandem mass spectrometry. The method was applied to the analysis of 941 archived plasma samples collected from patients before cardiac catheterization. When statin use was self-reported, statins were detected in 78.6% of the samples. In the case of self-reported atorvastatin use, the agreement with detection was 90.2%. However, when no statin use was reported, 42.4% of the samples had detectable levels of statins, with a similar range of concentrations as the samples from the self-reported statin users. The method is highly applicable in population studies designed for biomarker discovery or diet and lifestyle intervention studies, where the accuracy of statin or fibrate use may strongly affect the statistical evaluation of the biomarker data.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A sensitive, high-throughput LC-MS/MS method for measuring catecholamines in low volume serum
    Zheng, Jiamin
    Mandal, Rupasri
    Wishart, David S.
    ANALYTICA CHIMICA ACTA, 2018, 1037 : 159 - 167
  • [2] Fast LC for high-throughput LC-MS
    Wehr, T
    LC GC NORTH AMERICA, 2003, : 75 - 78
  • [3] Fast LC for high-throughput LC-MS
    Wehr, T
    LC GC NORTH AMERICA, 2002, 20 (01) : 40 - +
  • [4] Development of rapid and high-throughput LC-MS/MS method for quantification of olprinone in rabbit plasma
    Kertys, Martin
    Kosutova, Petra
    Mokra, Daniela
    Mokry, Juraj
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (10)
  • [5] Development and validation of a selective and robust LC-MS/MS method for high-throughput quantifying rizatriptan in small plasma samples: Application to a clinical pharmacokinetic study
    Chen, Yi
    Fan, Guorong
    Hong, Zhanying
    Wu, Huiling
    Wu, Yutian
    Lin, Mei
    Miao, Haijun
    DRUG METABOLISM REVIEWS, 2006, 38 : 107 - 107
  • [6] Development and validation of a selective and robust LC-MS/MS method for high-throughput quantifying rizatriptan in small plasma samples: Application to a clinical pharmacokinetic study
    Chen, Yi
    Miao, Haijun
    Lin, Mei
    Fan, Guorong
    Hong, Zhanying
    Wu, Huiling
    Wu, Yutian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (02): : 268 - 277
  • [7] A high-throughput LC-MS/MS method for simultaneous determination of isoniazid, ethambutol and pyrazinamide in human plasma
    Prso, Kristian
    Zidekova, Nela
    Porvaznik, Igor
    Solovic, Ivan
    Mokry, Juraj
    Kertys, Martin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (02)
  • [8] High-throughput toxicological analysis of Methamphetamine, MDA and MDMA from human plasma by LC-MS/MS
    Vlase, Laurian
    Popa, Daniela-Saveta
    Loghin, Felicia
    Leucuta, Sorin E.
    ROMANIAN JOURNAL OF LEGAL MEDICINE, 2009, 17 (03): : 213 - 220
  • [9] A high-throughput LC-MS/MS method for determination of flunarizine in human plasma: Pharmacokinetic study with different doses
    Bhadoriya, Abhaysingh
    Shah, Priyanka A.
    Shrivastav, Pranav S.
    Sanyal, Mallika
    Yadav, Manish S.
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (09)
  • [10] A sensitive and validated LC-MS/MS method for high-throughput determination of pomalidomide in human plasma and pharmacokinetic studies
    Shu, Chang
    Li, Teng-Fei
    Li, Duo
    Li, Zhong-Qiu
    Xia, Xing-Hua
    CHINESE CHEMICAL LETTERS, 2022, 33 (02) : 916 - 919