Validation of a digital method for patient-specific verification of VMAT treatment using a 2D ionisation detector array
被引:1
|
作者:
U'wais, Fatima Adel
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, MalaysiaUniv Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
U'wais, Fatima Adel
[1
]
Radzi, Yasmin
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Sch Phys, George Town 11800, MalaysiaUniv Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
Radzi, Yasmin
[2
]
Rizan, Naslinda Noor
论文数: 0引用数: 0
h-index: 0
机构:
Gleneagles Hosp, George Town, MalaysiaUniv Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
Rizan, Naslinda Noor
[3
]
Zin, Hafiz M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, MalaysiaUniv Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
Zin, Hafiz M.
[1
]
机构:
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
[2] Univ Sains Malaysia, Sch Phys, George Town 11800, Malaysia
VMAT treatment involves the delivery of complex beam parameters including the dynamic multi-leaf collimators (MLC) from a linac. The use of a detector array has become a standard method to verify the treatment accuracy before the treatment planned is delivered to the patient with some limitations. This study aims to evaluate the accuracy of a high-resolution, digital method using linac log data for VMAT treatment verification. The log data was obtained from a Versa HD (Elekta ltd., Crawley, UK) linac during VMAT treatment. All the dynamic treatment parameters including MLC position, and MLC speed, were recorded at the rate of 4 Hz in the log data. The treatment delivery was also measured simultaneously using an Octavius 1500 2D ionisation chamber array (PTW, Freiburg, Germany) during the log data measurements. The parameters were extracted and analysed using algorithms written in MATLAB (MathWorks, Natick, MA). The results demonstrated that the log data can track MLC leaves with an accuracy of 1 mm at speeds ranging from 3.04 to 3.40 cm/s. Evaluation of the fluence generated for the VMAT delivery using log data was shown to agree well with the planned dose distribution measured in the 2D detector array, with an average gamma pass rate of 97.5% at 3%/3 mm. Log data obtained a higher gamma pass rate of 98.5% compared to the 2D detector array of 97.5%. The digital linac log data provides the basis for an essential high-resolution real-time verification tool that may be used for routine VMAT verification.
机构:
Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
Harvard Med Sch, Boston, MA 02115 USA
Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC USAMassachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
Lin, Yuting
Bentefour, Hassan
论文数: 0引用数: 0
h-index: 0
机构:
IBA Ltd, Louvain La Neuve, BelgiumMassachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
Bentefour, Hassan
Flanz, Jacob
论文数: 0引用数: 0
h-index: 0
机构:
Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
Harvard Med Sch, Boston, MA 02115 USAMassachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
Flanz, Jacob
Kooy, Hanne
论文数: 0引用数: 0
h-index: 0
机构:
Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
Harvard Med Sch, Boston, MA 02115 USAMassachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
Kooy, Hanne
Clasie, Benjamin
论文数: 0引用数: 0
h-index: 0
机构:
Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
Harvard Med Sch, Boston, MA 02115 USAMassachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA