Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting

被引:39
作者
Freckmann, Guido [1 ,2 ]
Eichenlaub, Manuel [2 ]
Waldenmaier, Delia [2 ]
Pleus, Stefan [2 ]
Wehrstedt, Stephanie [2 ]
Haug, Cornelia [2 ]
Witthauer, Lilian [3 ,4 ,5 ]
Jendle, Johan [1 ,6 ]
Hinzmann, Rolf [1 ,7 ]
Thomas, Andreas [1 ]
Boija, Elisabet Eriksson [1 ,8 ]
Makris, Konstantinos [1 ,9 ]
Diem, Peter [1 ,10 ]
Nam Tran [1 ,11 ]
Klonoff, David C. [1 ,12 ]
Nichols, James H. [1 ,13 ]
Slingerland, Robbert J. [1 ,14 ]
机构
[1] IIFCC Sci Div, Working Grp Continuous Glucose Monitoring, Milan, Italy
[2] Univ Ulm, Inst Diabet Technol Forsch & Entwicklungsgesell M, Lise Meitner Str 8-2, D-89081 Ulm, Germany
[3] Diabet Ctr Berne, Bern, Switzerland
[4] Bern Univ Hosp, Dept Diabet Endocrinol Nutr Med & Metab, Inselspital Bern, Bern, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Orebro Univ, Sch Med Sci, Fac Med & Hlth, Orebro, Sweden
[7] Roche Diabet Care GmbH, Mannheim, Germany
[8] Equalis AB, Uppsala, Sweden
[9] KAT Gen Hosp, Dept Clin Biochem, Athens, Greece
[10] Endokrinol Diabetol Bern, Bern, Switzerland
[11] Univ Calif Davis Hlth, Dept Pathol & Lab Med, Sacramento, CA USA
[12] Mills Peninsula Med Ctr, Diabet Res Inst, San Mateo, CA USA
[13] Vanderbilt Univ, Med Ctr, Nashville, TN USA
[14] Isala Clin, Dept Clin Chem, Zwolle, Netherlands
关键词
continuous glucose monitoring; clinical performance evaluation; study design; accuracy; DEXCOM G4 PLATINUM; PROSPECTIVE MULTICENTER EVALUATION; TREATMENT EXPERIENCE; DIABETIC-PATIENTS; FREESTYLE LIBRE; ACCURACY; SENSOR; FLASH; CHILDREN; RELIABILITY;
D O I
10.1177/19322968231190941
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022. Specifically, this review quantifies the prevalence of numerous options associated with various aspects of study design, including subject population, comparator (reference) method selection, testing procedures, and statistical accuracy evaluation. We found that there is a large variability in nearly all of those aspects and, in particular, in the characteristics of the comparator measurements. Furthermore, these characteristics as well as other crucial aspects of study design are often not reported in sufficient detail to allow an informed interpretation of study results. We therefore provide recommendations for reporting the general study design, CGM system use, comparator measurement approach, testing procedures, and data analysis/statistical performance evaluation. Additionally, this review aims to serve as a foundation for the development of a standardized CGM performance evaluation procedure, thereby supporting the goals and objectives of the Working Group on CGM established by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine.
引用
收藏
页码:1506 / 1526
页数:21
相关论文
共 176 条
[1]   Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes [J].
Aberer, Felix ;
Hajnsek, Martin ;
Rumpler, Markus ;
Zenz, Sabine ;
Baumann, Petra M. ;
Elsayed, Hesham ;
Puffing, Adelheid ;
Treiber, Gerlies ;
Pieber, Thomas R. ;
Sourij, Harald ;
Mader, Julia K. .
DIABETES OBESITY & METABOLISM, 2017, 19 (07) :1051-1055
[2]   Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes [J].
Alva, Shridhara ;
Bailey, Timothy ;
Brazg, Ronald ;
Budiman, Erwin S. ;
Castorino, Kristin ;
Christiansen, Mark P. ;
Forlenza, Gregory ;
Kipnes, Mark ;
Liljenquist, David R. ;
Liu, Hanqing .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (01) :70-77
[4]  
Andelin Mervi, 2016, J Diabetes Sci Technol, V10, P876, DOI 10.1177/1932296815626724
[5]  
[Anonymous], Evaluation of Automatic Class III Designation for FilmArray Meningitis/Encephalitis
[6]  
[Anonymous], 2004, DIABETES CARE, V27, P722, DOI [DOI 10.2337/DIACARE.27.3.722, 10.2337/diacare.27.3.722]
[7]   First assessment of the performance of an implantable continuous glucose monitoring system through 180 days in a primarily adolescent population with type 1 diabetes [J].
Aronson, Ronnie ;
Abitbol, Alexander ;
Tweden, Katherine S. .
DIABETES OBESITY & METABOLISM, 2019, 21 (07) :1689-1694
[8]   Flash glucose monitoring in type 1 diabetes: A comparison with self-monitoring blood glucose [J].
Babaya, Naru ;
Noso, Shinsuke ;
Hiromine, Yoshihisa ;
Taketomo, Yasunori ;
Niwano, Fumimaru ;
Yoshida, Sawa ;
Yasutake, Sara ;
Kawabata, Yumiko ;
Ikegami, Hiroshi .
JOURNAL OF DIABETES INVESTIGATION, 2020, 11 (05) :1222-1229
[9]   The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System [J].
Bailey, Timothy ;
Bode, Bruce W. ;
Christiansen, Mark P. ;
Klaff, Leslie J. ;
Alva, Shridhara .
DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) :787-794
[10]   New Features and Performance of a Next-Generation SEVEN-Day Continuous Glucose Monitoring System with Short Lag Time [J].
Bailey, Timothy ;
Zisser, Howard ;
Chang, Anna .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (12) :749-755