Chronic Effects of e-Cigarette Aerosol Inhalation on Macular Perfusion Assessed Using OCT Angiography

被引:0
作者
Ponugoti, Arathi [1 ]
Ngo, Hoan [2 ]
Stinnett, Sandra [1 ]
Vajzovic, Lejla [1 ,3 ]
机构
[1] Duke Univ, Ctr Eye, Dept Ophthalmol, Durham, NC USA
[2] Int Univ VNU HCM, Sch Biomed Engn, Ho Chi Minh City, Vietnam
[3] Duke Eye Ctr, Dept Ophthalmol, 2351 Erwin Rd, Durham, NC 27705 USA
关键词
retina; optical coherence tomography (OCT); optical coherence tomography angiography (OCTA); retinal vascular disease; retinal manifestations of systemic disease; BLOOD-FLOW; SMOKING; TOBACCO;
D O I
10.1177/24741264231205071
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine whether there are significant differences in the microvasculature and central retinal thickness (CRT) between e-cigarette users (user group) and age-matched nonusers (control group) using optical coherence tomography angiography (OCTA). Methods: In this prospective cross-sectional observational study, OCTA images were acquired of 52 eyes of 26 users and 25 eyes of 25 age-matched nonusers. Daily e-cigarette users with no ocular history were identified from provider information in the electronic medical record. A custom algorithm was used to calculate the foveal avascular zone (FAZ), vessel area density (VAD), and vessel length density (VLD). OCT software was used to calculate the foveal, superior, inferior, nasal, and temporal CRT. Generalized estimating equations using the Z-statistic were used to determine how the FAZ, VAD, VLD, and CRT parameters varied between groups and to assess the differential contribution of descriptive data in the user group. Results: No statistically significant difference was found between the user group and control group in the FAZ, superficial vascular complex (SVC) VAD, SVC VLD, or deep vascular complex (DVC) VAD. A statistically significant difference was found for DVC VLD (P = .002), with the user group having a slightly higher VLD on average. Superior, temporal, and inferior inner macular thicknesses were significantly thinner in the user group (P = .038, P = .012, and P = .035, respectively). Conclusions: Significant negative differences were found in CRT measures but not in retinal microvasculature parameters between e-cigarette users and nonusers. Decreased inferior, temporal, and superior inner macular thickness in e-cigarette users may show an early chronic structural effect that warrants further assessment of retinal effects as this population ages and continues to use e-cigarettes.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 25 条
[1]   Central macular thickness in patients with sickle cell disease and no signs of retinopathy: a cross-sectional study of Jordanian patients [J].
Abu-Yaghi, Nakhleh E. ;
AlNawaiseh, Ahmad M. ;
Khourshid, Issam M. ;
AlRawashdeh, Tala J. ;
Al Rawashdeh, Majd M. ;
Zghoul, Ayat M. ;
Shafagoj, Abdallah N. ;
Alomairi, Yousif A. ;
Muhsen, Sana' M. ;
AlRyalat, SaifAldeen S. .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (04)
[2]  
Alnawaiseh M, 2017, RETINA-J RET VIT DIS, V37, P1642, DOI 10.1097/IAE.0000000000001419
[3]   Evaluation of Macular Perfusion in Healthy Smokers by Using Optical Coherence Tomography Angiography [J].
Ayhan, Ziya ;
Kaya, Mahmut ;
Ozturk, Taylan ;
Karti, Omer ;
Oner, F. Hakan .
OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2017, 48 (08) :617-622
[4]   Structural Abnormalities of the Inner Macula in Incontinentia Pigmenti [J].
Basilius, Jacob ;
Young, Marielle P. ;
Michaelis, Timothy C. ;
Hobbs, Ronald ;
Jenkins, Glen ;
Hartnett, M. Elizabeth .
JAMA OPHTHALMOLOGY, 2015, 133 (09) :1067-1072
[5]   Optical coherence tomography angiography-derived flow density: a review of the influencing factors [J].
Bruecher, Viktoria C. ;
Storp, Jens J. ;
Eter, Nicole ;
Alnawaiseh, Maged .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (04) :701-710
[6]   Acute Effects of Electronic Cigarette Aerosol Inhalation on Vascular Function Detected at Quantitative MRI [J].
Caporale, Alessandra ;
Langham, Michael C. ;
Guo, Wensheng ;
Johncola, Alyssa ;
Chatterjee, Shampa ;
Wehrli, Felix W. .
RADIOLOGY, 2019, 293 (01) :97-106
[7]   Acute Impact of Tobacco vs Electronic Cigarette Smoking on Oxidative Stress and Vascular Function [J].
Carnevale, Roberto ;
Sciarretta, Sebastiano ;
Violi, Francesco ;
Nocella, Cristina ;
Loffredo, Lorenzo ;
Perri, Ludovica ;
Peruzzi, Mariangela ;
Marullo, Antonino G. M. ;
De Falco, Elena ;
Chimenti, Isotta ;
Valenti, Valentina ;
Biondi-Zoccai, Giuseppe ;
Frati, Giacomo .
CHEST, 2016, 150 (03) :606-612
[8]   Immediate effects of smoking on optic nerve and macular perfusion measured by optical coherence tomography angiography [J].
Ciesielski, Maksym ;
Rakowicz, Piotr ;
Stopa, Marcin .
SCIENTIFIC REPORTS, 2019, 9 (1)
[9]   Use of Electronic Cigarettes and Any Tobacco Product Among Middle and High School Students - United States, 2011-2018 [J].
Cullen, Karen A. ;
Ambrose, Bridget K. ;
Gentzke, Andrea S. ;
Apelberg, Benjamin J. ;
Jamal, Ahmed ;
King, Brian A. .
MMWR-MORBIDITY AND MORTALITY WEEKLY REPORT, 2018, 67 (45) :1276-1277
[10]   Cigarette smoking reduces deep retinal vascular density [J].
Febo, Mustafa Dogan ;
Akdogan, Muberra ;
Gulyesil, Furkan Fatih ;
Sabaner, Mehmet Cem ;
Gobeka, Hamidu Hamisi .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2020, 103 (06) :838-842