Seismic retrofit of structures using added steel column friction dampers

被引:5
作者
Javidan, Mohammad Mahdi [1 ]
Naeem, Asad [2 ]
Kim, Jinkoo [1 ]
机构
[1] Sungkyunkwan Univ, Dept Global Smart City, Suwon, South Korea
[2] Balochistan Univ Informat Technol, Dept Civil & Architectural Engn, Quetta, Pakistan
基金
新加坡国家研究基金会;
关键词
friction damper; nonlinear time history analysis; seismic dampers; seismic performance; seismic retrofit; PERFORMANCE EVALUATION; FRAME;
D O I
10.12989/scs.2023.49.3.257
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, the feasibility and applicability of a friction damper with a vertical installation scheme are investigated. This device is composed of a steel section and two friction hinges at both ends which dissipate seismic energy. Due to its small width and vertical installation scheme, the proposed damper can minimize the interference with architectural functions. To evaluate the performance of the proposed damper, its mechanical behavior is theoretically evaluated and the required formulas for the yield strength and elastic stiffness are derived. The theoretical formulas are verified by establishing the analytical model of the damper in the SAP2000 software and comparing their results. To further investigate the performance of the developed damper, the provided analytical model is applied to a 4-story reinforced concrete (RC) structure and its performance is evaluated before and after retrofit under the Maximum Considered Earthquake (MCE) hazard level. The seismic performance is thoroughly evaluated in terms of maximum interstory drift ratio, displacement time history, residual displacement, and energy dissipation. The results show that the proposed damper can be efficiently used to protect the structure against seismic loads.
引用
收藏
页码:257 / 270
页数:14
相关论文
共 50 条
[21]   Experimental dynamic characterization of friction brace dampers and application to the seismic retrofit of RC buildings [J].
Saingam, Panumas ;
Matsuzaki, Ryota ;
Nishikawa, Koki ;
Sitler, Ben ;
Terazawa, Yuki ;
Takeuchi, Toru .
ENGINEERING STRUCTURES, 2021, 242
[22]   Performance-based seismic retrofit of RC structures using concentric braced frames equipped with friction dampers and disc springs [J].
Noureldin, Mohamed ;
Memon, Shabir Ahmed ;
Gharagoz, Masom ;
Kim, Jinkoo .
ENGINEERING STRUCTURES, 2021, 243
[23]   Seismic analysis of structures connected with friction dampers [J].
Bhaskararao, AV ;
Jangid, RS .
ENGINEERING STRUCTURES, 2006, 28 (05) :690-703
[24]   Risk-based optimal retrofit of a tall steel building by using friction dampers [J].
Tafakori, Ehsan ;
Banazadeh, Mehdi ;
Jalali, Seyed Alireza ;
Tehranizadeh, Mohsen .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2013, 22 (09) :700-717
[25]   Study on seismic retrofit of structures using SPSW systems and LYP steel material [J].
Zirakian, Tadeh ;
Zhang, Jian .
EARTHQUAKES AND STRUCTURES, 2016, 10 (01) :1-23
[26]   Application of a Comprehensive Seismic Retrofit Procedure for Steel Buildings Using Nonlinear Viscous Dampers [J].
Bahmani, Mohammad ;
Zahrai, Seyed Mehdi .
INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2019, 17 (8A) :1261-1279
[27]   Application of a Comprehensive Seismic Retrofit Procedure for Steel Buildings Using Nonlinear Viscous Dampers [J].
Mohammad Bahmani ;
Seyed Mehdi Zahrai .
International Journal of Civil Engineering, 2019, 17 :1261-1279
[28]   Seismic retrofit of framed structures using a steel frame assembly [J].
Adane, Michael ;
Chun, Seungho ;
Kim, Jinkoo .
STEEL AND COMPOSITE STRUCTURES, 2023, 46 (06) :857-865
[29]   Experimental study on seismic retrofit of a RC frame using viscoelastic dampers [J].
Nasab, Mohammad Seddiq Eskandari ;
Javidan, Mohammad Mahdi ;
Chun, Seungho ;
Kim, Jinkoo .
STRUCTURES, 2021, 34 :771-786
[30]   Optimal distribution of friction dampers for seismic retrofit of a reinforced concrete moment frame [J].
Kim, Jinkoo ;
An, Seeun .
ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (10) :1523-1539