Non-Directional Property of Human-Body Communication Channel for Implantable Device Application

被引:0
|
作者
Jung, Jaehyo [1 ]
Choi, Daegil [1 ]
Kim, Da Eun [1 ]
Li, Meina [2 ,3 ]
机构
[1] Chosun Univ, AI Healthcare Res Ctr, Dept IT Fus Technol, Gwangju 61452, South Korea
[2] Jilin Univ, Dept Instrument Sci & Technol, Changchun 130061, Peoples R China
[3] Jilin Univ, Yibin Res Inst, Yibin 644000, Peoples R China
关键词
human-body communication; implantable device; channel measurement; impulse response; ANTENNA;
D O I
10.3390/s23156754
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we present the properties of a communication channel used for implantable devices. The human-body communication (HBC) channel was proposed for data communication in implantable devices. The impulse response was measured using a channel-mimicking model, which mimics electrical losses caused by human body tissues. Furthermore, we compared two types of channel-mimicking models to evaluate their applicability depending on the measurement environment. The resultant impulse responses of the HBC channel showed that HBC does not cause severe changes in the channel properties even when the implantable device is rotated.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Measurement and analysis of channel attenuation characteristics for an implantable galvanic coupling human-body communication
    Zhang, Shuang
    Pun, Sio Hang
    Mak, Peng Un
    Qin, Yu-Ping
    Liu, Yi-He
    Vai, Mang I.
    TECHNOLOGY AND HEALTH CARE, 2016, 24 (06) : 821 - 826
  • [2] The constrained principal property (CPP) space in QSAR - Directional and non-directional modelling approaches
    Eriksson, L
    Andersson, P
    Johansson, E
    Tysklind, M
    Sandberg, M
    Wold, S
    MOLECULAR MODELING AND PREDICTION OF BIOACTIVITY, 2000, : 65 - 70
  • [3] Path loss modeling and verification of implantable human-body communication based on a point source field
    Yan, Dan-Dan
    Zhang, Tao
    Zhang, Shuang
    TECHNOLOGY AND HEALTH CARE, 2020, 28 (03) : 283 - 292
  • [4] THE APPLICATION OF MOIRE CONTOUROGRAPHY TO HUMAN-BODY
    ZHANG, RX
    LAN, ZY
    ZHANG, XZ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 389 : 59 - 61
  • [5] Body Coupled Communication: The Channel and Implantable Sensors
    Anderson, Grant S.
    Sodini, Charles G.
    2013 IEEE INTERNATIONAL CONFERENCE ON BODY SENSOR NETWORKS (BSN), 2013,
  • [6] Mathematical Model of Tissue Characteristics in Human-Body Communication
    Qin, Yuping
    Zhang, Shuang
    Liu, Yihe
    PROCEEDINGS OF THE 2016 6TH INTERNATIONAL CONFERENCE ON MANAGEMENT, EDUCATION, INFORMATION AND CONTROL (MEICI 2016), 2016, 135 : 455 - 460
  • [7] 1ST IMPLANTATION OF A 16-CHANNEL ELECTRIC-STIMULATION DEVICE IN THE HUMAN-BODY
    THOMA, H
    FREY, M
    GRUBER, H
    HOLLE, J
    KERN, H
    REINER, E
    SCHWANDA, G
    STOHR, H
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1983, 29 : 301 - 306
  • [8] Asymmetry, developmental instability and non-directional growth constraints in the human skull.
    DeLeon, VB
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2003, : 86 - 86
  • [9] Calculation and application of non-directional near-horizontal borehole trajectory parameters
    Gao J.
    Qin S.
    Zhang J.
    Chang L.
    Caikuang yu Anquan Gongcheng Xuebao/Journal of Mining and Safety Engineering, 2024, 41 (02): : 341 - 351
  • [10] Modeling of human-body near-field communication and evaluation of communication quality
    Sasaki, Ai-Ichiro
    Kawano, Ryusuke
    Ishihara, Takako
    Shinagawa, Mitsuru
    NTT Technical Review, 2010, 8 (03):