Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging

被引:0
作者
Hatipoglu, Filiz [1 ]
Cetin, Neslihan [2 ]
机构
[1] Ataturk Training & Res Hosp, Clin Nucl Med, Izmir, Turkiye
[2] Umraniye Training & Res Hosp, Clin Nucl Med, Istanbul, Turkiye
关键词
Myocardial perfusion; scintigraphy; attenuation correction; COMPUTED-TOMOGRAPHY; DIAGNOSTIC PERFORMANCE; TASK-FORCE; ARTIFACTS; SCATTER; GUIDELINES; COMMITTEE; ACCURACY; HEART; TRIAL;
D O I
10.4274/mirt.galenos.2022.68094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We aimed to investigate and compare the role of computed tomography (CT)-based attenuation-corrected images (AC) with non -attenuation-corrected images (NAC) obtained by single-photon emission computed tomography/computed tomography (SPECT/CT) myocardial perfusion imaging (MPI).Methods: The data of 124 patients who were applied one-day stress-rest Tc-99m sestamibi SPECT/CT MPI and who had coronary angiography (CAG) results within & PLUSMN;3 months were retrospectively reviewed. AC and NAC images were visually evaluated by two nuclear medicine specialists in a consensus. CAG results were used as the reference standard.Results: Specificity, sensitivity, and accuracy were calculated as 66%, 61%, 71%, 79% and 69%, 70% for AC and NAC imaging in the whole group, respectively. There was no statistically significant difference between AC and NAC images for specificity, sensitivity, and accuracy in the male and female subgroups. In the diagnosis of right coronary artery (RCA) disease, CT AC significantly increased the specificity from 87% to 96%. However, in the left anterior descending artery (LAD) region, the specificity was significantly reduced from 95% to 77%. Conclusion: CT-based AC did not significantly contribute to diagnostic performance for increased specificity for the RCA and reduced specificity in the LAD region. Therefore, AC images should always be evaluated side by side with NAC images to benefit from the different advantages of both techniques.
引用
收藏
页码:138 / 145
页数:8
相关论文
共 31 条
[11]   SPECT attenuation correction: An essential tool to realize nuclear cardiology's manifest destiny [J].
Garcia, Ernest V. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (01) :16-24
[12]  
Genovesi D, EUR
[13]   Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging [J].
Hendel, RC ;
Berman, DS ;
Cullom, SJ ;
Follansbee, W ;
Heller, GV ;
Kiat, H ;
Groch, MW ;
Mahmarian, JJ .
CIRCULATION, 1999, 99 (21) :2742-2749
[14]   Hybrid SPECT/CT for Attenuation Correction of Stress Myocardial Perfusion Imaging [J].
Huang, Rui ;
Li, Fanglan ;
Zhao, Zhen ;
Liu, Bin ;
Ou, Xiaohong ;
Tian, Rong ;
Li, Lin .
CLINICAL NUCLEAR MEDICINE, 2011, 36 (05) :344-349
[15]   Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging [J].
Johansen, A ;
Grupe, P ;
Veje, A ;
Braad, PEN ;
Hoilund-Carlsen, PF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (08) :1152-1159
[16]  
Kalantari F, 2011, HELL J NUCL MED, V14, P278
[17]   ACC/AHA/ASNC uidelines for the clinical use of cardiac radionuclide imaging - Executive summary - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to revise the 1995 guidelines for the clinical use of cardiac radionuclide imaging) [J].
Klocke, FJ ;
Baird, MG ;
Lorell, BH ;
Bateman, TM ;
Messer, JV ;
Berman, DS ;
O'Gara, PT ;
Carabello, BA ;
Russell, RO ;
Cerqueira, MD ;
Sutton, MGS ;
DeMaria, AN ;
Udelson, JE ;
Kennedy, JW ;
Verani, MS ;
Williams, KA ;
Antman, EM ;
Smith, SC ;
Alpert, JS ;
Gregoratos, G ;
Anderson, JL ;
Hiratzka, LF ;
Faxon, DP ;
Hunt, SA ;
Fuster, V ;
Jacobs, AK ;
Gibbons, RJ ;
Russell, RO .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (07) :1318-1333
[18]   Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: A multicenter trial [J].
Links, JM ;
Becker, LC ;
Rigo, P ;
Taillefer, R ;
Hanelin, L ;
Anstett, F ;
Burckhardt, D ;
Mixon, L .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (05) :414-425
[19]   Clinical validation of SPECT attenuation correction using X-ray computed tomography-derived attenuation maps: Multicenter clinical trial with angiographic correlation [J].
Masood, Y ;
Liu, YH ;
DePuey, G ;
Taillefer, R ;
Araujo, LI ;
Allen, S ;
Delbeke, D ;
Anstett, F ;
Peretz, A ;
Zito, MJ ;
Tsatkin, V ;
Wackers, FJT .
JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (06) :676-686
[20]   Cardiac Event Risk in Japanese Subjects Estimated Using Gated Myocardial Perfusion Imaging, in Conjunction With Diabetes Mellitus and Chronic Kidney Disease [J].
Nakajima, Kenichi ;
Matsuo, Shinro ;
Okuyama, Chio ;
Hatta, Tsuguru ;
Tsukamoto, Kazumasa ;
Nishimura, Shigeyuki ;
Yamashina, Akira ;
Kusuoka, Hideo ;
Nishimura, Tsunehiko .
CIRCULATION JOURNAL, 2012, 76 (01) :168-175