Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging

被引:0
|
作者
Hatipoglu, Filiz [1 ]
Cetin, Neslihan [2 ]
机构
[1] Ataturk Training & Res Hosp, Clin Nucl Med, Izmir, Turkiye
[2] Umraniye Training & Res Hosp, Clin Nucl Med, Istanbul, Turkiye
关键词
Myocardial perfusion; scintigraphy; attenuation correction; COMPUTED-TOMOGRAPHY; DIAGNOSTIC PERFORMANCE; TASK-FORCE; ARTIFACTS; SCATTER; GUIDELINES; COMMITTEE; ACCURACY; HEART; TRIAL;
D O I
10.4274/mirt.galenos.2022.68094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We aimed to investigate and compare the role of computed tomography (CT)-based attenuation-corrected images (AC) with non -attenuation-corrected images (NAC) obtained by single-photon emission computed tomography/computed tomography (SPECT/CT) myocardial perfusion imaging (MPI).Methods: The data of 124 patients who were applied one-day stress-rest Tc-99m sestamibi SPECT/CT MPI and who had coronary angiography (CAG) results within & PLUSMN;3 months were retrospectively reviewed. AC and NAC images were visually evaluated by two nuclear medicine specialists in a consensus. CAG results were used as the reference standard.Results: Specificity, sensitivity, and accuracy were calculated as 66%, 61%, 71%, 79% and 69%, 70% for AC and NAC imaging in the whole group, respectively. There was no statistically significant difference between AC and NAC images for specificity, sensitivity, and accuracy in the male and female subgroups. In the diagnosis of right coronary artery (RCA) disease, CT AC significantly increased the specificity from 87% to 96%. However, in the left anterior descending artery (LAD) region, the specificity was significantly reduced from 95% to 77%. Conclusion: CT-based AC did not significantly contribute to diagnostic performance for increased specificity for the RCA and reduced specificity in the LAD region. Therefore, AC images should always be evaluated side by side with NAC images to benefit from the different advantages of both techniques.
引用
收藏
页码:138 / 145
页数:8
相关论文
共 50 条
  • [1] Clinical utility of attenuation correction with X-rays in myocardial perfusion SPECT studies
    Bajen, M. T.
    Ricart, Y.
    Rodriguez-Gasen, A.
    Mora, J.
    Quintana, M. E.
    Benitez, A.
    Domenech, A.
    Ruiz-Mayoral, A.
    Puchala, R.
    Pallares, C.
    Martin-Comin, J.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2007, 26 (06): : 359 - 366
  • [2] CT-based attenuation and scatter correction compared with uniform attenuation correction in brain perfusion SPECT imaging for dementia
    Gillen, Rebecca
    Firbank, Michael J.
    Lloyd, Jim
    O'Brien, John T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (17) : 6775 - 6787
  • [3] Hybrid SPECT/CT for Attenuation Correction of Stress Myocardial Perfusion Imaging
    Huang, Rui
    Li, Fanglan
    Zhao, Zhen
    Liu, Bin
    Ou, Xiaohong
    Tian, Rong
    Li, Lin
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (05) : 344 - 349
  • [4] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Zhang, Duo
    Yang, Bang-Hung
    Wu, Nien Yun
    Mok, Greta Seng Peng
    ANNALS OF NUCLEAR MEDICINE, 2017, 31 (02) : 172 - 180
  • [5] The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
    Saleki, Leila
    Ghafarian, Pardis
    Bitarafan-Rajabi, Ahmad
    Yaghoobi, Nahid
    Fallahi, Babak
    Ay, Mohammad Reza
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 27 (02): : 63 - 72
  • [6] What is the benefit of CT-based attenuation correction in myocardial perfusion SPET?
    Apostolopoulos, Dimitrios J.
    Savvopoulos, Christos
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2016, 19 (02): : 89 - 92
  • [7] Comparative Accuracy of CT Attenuation-Corrected and Non-Attenuation-Corrected SPECT Myocardial Perfusion Imaging
    Sharma, Punit
    Patel, Chetan D.
    Karunanithi, Sellam
    Maharjan, Sagar
    Malhotra, Arun
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (04) : 332 - 338
  • [8] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Duo Zhang
    Bang-Hung Yang
    Nien Yun Wu
    Greta Seng Peng Mok
    Annals of Nuclear Medicine, 2017, 31 : 172 - 180
  • [9] The effect of CT-based attenuation correction on the automatic perfusion score of myocardial perfusion imaging using a dedicated cardiac solid-state CZT SPECT/CT
    Kennedy, John A.
    Brodov, Yafim
    Weinstein, Adam L.
    Israel, Ora
    Frenkel, Alex
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (01) : 236 - 245
  • [10] Clinical Impact of Nonuniform CT-Based Attenuation Correction in Brain Perfusion SPECT/CT Using 99mTc-ECD
    Farid, Karim
    Petras, Slavomir
    Poullias, Xavier
    Caillat-Vigneron, Nadine
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (06) : E343 - E345