Clinical applications of contactless photoplethysmography for vital signs monitoring in pediatrics: A systematic review and meta-analysis

被引:1
作者
Bautista, Melissa [1 ,2 ]
Cave, Daniel [1 ,3 ]
Downey, Candice [1 ,2 ]
Bentham, James R. [1 ,3 ]
Jayne, David [1 ,2 ]
机构
[1] Univ Leeds, Leeds, W Yorkshire, England
[2] Leeds Teaching Hosp NHS Trust, St Jamess Univ Hosp, Gen Surg Dept, Leeds, W Yorkshire, England
[3] Leeds Teaching Hosp NHS Trust, Leeds Childrens Hosp, Leeds, W Yorkshire, England
关键词
Vital signs monitoring; photoplethysmography; paediatrics; children; neonates; heart rate; respiratory rate; systematic review; meta-analysis; HEART-RATE; ROBUST;
D O I
10.1017/cts.2023.557
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background:Contactless photoplethysmography (PPG) potentially affords the ability to obtain vital signs in pediatric populations without disturbing the child. Most validity studies have been conducted in laboratory settings or with healthy adult volunteers. This review aims to evaluate the current literature on contactless vital signs monitoring in pediatric populations and within a clinical setting. Methods:OVID, Webofscience, Cochrane library, and clinicaltrials.org were systematically searched by two authors for research studies which used contactless PPG to assess vital signs in children and within a clinical setting. Results:Fifteen studies were included with a total of 170 individuals. Ten studies were included in a meta-analysis for neonatal heart rate (HR), which demonstrated a pooled mean bias of -0.25 (95% limits of agreement (LOA), -1.83 to 1.32). Four studies assessed respiratory rate (RR) in neonates, and meta-analysis demonstrated a pooled mean bias of 0.65 (95% LOA, -3.08 to 4.37). All studies were small, and there were variations in the methods used and risk of bias. Conclusion:Contactless PPG is a promising tool for vital signs monitoring in children and accurately measures neonatal HR and RR. Further research is needed to assess children of different age groups, the effects of skin type variation, and the addition of other vital signs.
引用
收藏
页数:8
相关论文
共 27 条
  • [1] Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - A pilot study
    Aarts, Lonneke A. M.
    Jeanne, Vincent
    Cleary, John P.
    Lieber, C.
    Nelson, J. Stuart
    Oetomo, Sidarto Bambang
    Verkruysse, Wim
    [J]. EARLY HUMAN DEVELOPMENT, 2013, 89 (12) : 943 - 948
  • [2] Photoplethysmography and its application in clinical physiological measurement
    Allen, John
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) : R1 - R39
  • [3] MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES
    ALTMAN, DG
    BLAND, JM
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) : 307 - 317
  • [4] Antognoli L, 2018, IEEE INT SYM MED MEA, P997
  • [5] Non-contact estimation of heart rate and oxygen saturation using ambient light
    Bal, Ufuk
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (01): : 86 - 97
  • [6] Bersani I, 2021, EUR J PEDIATR, V180, P1335, DOI 10.1007/s00431-020-03882-3
  • [7] Remote vital parameter monitoring in neonatology - robust, unobtrusive heart rate detection in a realistic clinical scenario
    Blanik, Nikolai
    Heimann, Konrad
    Pereira, Carina
    Paul, Michael
    Blazek, Vladimir
    Venema, Boudewijn
    Orlikowsky, Thorsten
    Leonhardt, Steffen
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2016, 61 (06): : 631 - 643
  • [8] Cenci A, 2016, INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 9
  • [9] Camera-based heart rate estimation for hospitalized newborns in the presence of motion artifacts
    Chen, Qiong
    Wang, Yalin
    Liu, Xiangyu
    Long, Xi
    Yin, Bin
    Chen, Chen
    Chen, Wei
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2021, 20 (01)
  • [10] Chen Q, 2020, IEEE ENG MED BIO, P5822, DOI 10.1109/EMBC44109.2020.9175651