Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising

被引:9
|
作者
Koons, Emily K. K. [1 ,2 ]
Thorne, Jamison E. E. [1 ]
Huber, Nathan R. R. [1 ]
Chang, Shaojie [1 ]
Rajendran, Kishore [1 ]
McCollough, Cynthia H. H. [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Biomed Engn & Physiol, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
computed tomography; convolutional neural network; coronary artery stents; denoising; photon counting detector; RESTENOSIS;
D O I
10.1002/mp.16415
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundSmall coronary arteries containing stents pose a challenge in CT imaging due to metal-induced blooming artifact. High spatial resolution imaging capability is as the presence of highly attenuating materials limits noninvasive assessment of luminal patency. PurposeThe purpose of this study was to quantify the effective lumen diameter within coronary stents using a clinical photon-counting-detector (PCD) CT in concert with a convolutional neural network (CNN) denoising algorithm, compared to an energy-integrating-detector (EID) CT system. MethodsSeven coronary stents of different materials and inner diameters between 3.43 and 4.72 mm were placed in plastic tubes of diameters 3.96-4.87 mm containing 20 mg/mL of iodine solution, mimicking stented contrast-enhanced coronary arteries. Tubes were placed parallel with or perpendicular to the scanner's z-axis in an anthropomorphic phantom emulating an average-sized patient and scanned with a clinical EID-CT and PCD-CT. EID scans were performed using our standard coronary computed tomography angiography (cCTA) protocol (120 kV, 180 quality reference mAs). PCD scans were performed using the ultra-high-resolution (UHR) mode (120 x 0.2 mm collimation) at 120 kV with tube current adjusted so that CTDIvol was matched to that of EID scans. EID images were reconstructed per our routine clinical protocol (Br40, 0.6 mm thickness), and with the sharpest available kernel (Br69). PCD images were reconstructed at a thickness of 0.6 mm and a dedicated sharp kernel (Br89) which is only possible with the PCD UHR mode. To address increased image noise introduced by the Br89 kernel, an image-based CNN denoising algorithm was applied to the PCD images of stents scanned parallel to the scanner's z-axis. Stents were segmented based on full-width half maximum thresholding and morphological operations, from which effective lumen diameter was calculated and compared to reference sizes measured with a caliper. ResultsSubstantial blooming artifacts were observed on EID Br40 images, resulting in larger stent struts and reduced lumen diameter (effective diameter underestimated by 41% and 47% for parallel and perpendicular orientations, respectively). Blooming artifacts were observed on EID Br69 images with 19% and 31% underestimation of lumen diameter compared to the caliper for parallel and perpendicular scans, respectively. Overall image quality was substantially improved on PCD, with higher spatial resolution and reduced blooming artifacts, resulting in the clearer delineation of stent struts. Effective lumen diameters were underestimated by 9% and 19% relative to the reference for parallel and perpendicular scans, respectively. CNN reduced image noise by about 50% on PCD images without impacting lumen quantification (<0.3% difference). ConclusionThe PCD UHR mode improved in-stent lumen quantification for all seven stents as compared to EID images due to decreased blooming artifacts. Implementation of CNN denoising algorithms to PCD data substantially improved image quality.
引用
收藏
页码:4173 / 4181
页数:9
相关论文
共 50 条
  • [31] Ultrasonic adaptive plane wave high-resolution imaging based on convolutional neural network
    Zhang, Fuben
    Luo, Lin
    Li, Jinlong
    Peng, Jianping
    Zhang, Yu
    Gao, Xiaorong
    NDT & E INTERNATIONAL, 2023, 138
  • [32] HIGH-RESOLUTION COMPUTED TOMOGRAPHY BRONCHIAL LUMEN TO PULMONARY ARTERY DIAMETER RATIO IN ANESTHETIZED VENTILATED CATS WITH NORMAL LUNGS
    Reid, Lauren E.
    Dillon, A. Ray
    Hathcock, John T.
    Brown, Lawrence A.
    Tillson, Michael
    Wooldridge, Anne A.
    VETERINARY RADIOLOGY & ULTRASOUND, 2012, 53 (01) : 34 - 37
  • [33] Low-Dose High-Resolution Photon-Counting CT of the Lung: Radiation Dose and Image Quality in the Clinical Routine
    Woeltjen, Matthias Michael
    Niehoff, Julius Henning
    Michael, Arwed Elias
    Horstmeier, Sebastian
    Moenninghoff, Christoph
    Borggrefe, Jan
    Kroeger, Jan Robert
    DIAGNOSTICS, 2022, 12 (06)
  • [34] High-pitch, high temporal resolution, multi-energy cardiac imaging on a dual-source photon-counting-detector CT
    Ahmed, Zaki
    Campeau, David
    Gong, Hao
    Rajendran, Kishore
    Rajiah, Prabhakar
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL PHYSICS, 2023, 50 (03) : 1428 - 1435
  • [35] Coronary CT angiography-based FFR with ultrahigh-resolution photon-counting detector CT: Intra-individual comparison to energy-integrating detector CT
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    Gnasso, Chiara
    Zsarnoczay, Emese
    Fink, Nicola
    Kravchenko, Dmitrij
    Hagar, Muhammad Taha
    Halfmann, Moritz C.
    Jokkel, Zsofia
    O'Doherty, Jim
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Suranyi, Pal Spruill
    Varga-Szemes, Akos
    Emrich, Tilman
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [36] Classification of High-Resolution Remote Sensing Image Based on Swin Transformer and Convolutional Neural Network
    He Xiaoying
    Xu Weiming
    Pan Kaixiang
    Wang Juan
    Li Ziwei
    LASER & OPTOELECTRONICS PROGRESS, 2024, 61 (14)
  • [37] Convolutional Neural Network for High-Resolution Cloud Motion Prediction from Hemispheric Sky Images
    Crisosto, Cristian
    Luiz, Eduardo W.
    Seckmeyer, Gunther
    ENERGIES, 2021, 14 (03)
  • [38] Cost-effectiveness of ultrahigh-resolution photon-counting detector coronary CT angiography for the evaluation of stable chest pain
    Vecsey-Nagy, Milan
    Emrich, Tilman
    Tremamunno, Giuseppe
    Kravchenko, Dmitrij
    Hagar, Muhammad Taha
    Laux, Gerald S.
    Schoepf, U. Joseph
    O'Doherty, Jim
    Boussoussou, Melinda
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Kroencke, Thomas
    Kabakus, Ismail Mikdat
    Suranyi, Pal Spruill
    Varga-Szemes, Akos
    Decker, Josua A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2025, 19 (01) : 106 - 112
  • [39] Quantification of coronary artery stenosis with high-resolution CT in comparison with histopathology in an ex vivo study
    Dettmer, Matthias
    Glaser-Gallion, Nicola
    Stolzmann, Paul
    Glaser-Gallion, Florian
    Fornaro, Juergen
    Feuchtner, Gudrun
    Jochum, Wolfram
    Alkadhi, Hatem
    Wildermuth, Simon
    Leschka, Sebastian
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 264 - 269
  • [40] Dose Reduction and Image Quality in Photon-counting Detector High-resolution Computed Tomography of the Chest Routine Clinical Data
    Graafen, Dirk
    Emrich, Tilman
    Halfmann, Moritz C.
    Mildenberger, Peter
    Dueber, Christoph
    Yang, Yang
    Othman, Ahmed E.
    O' Doherty, Jim
    Mueller, Lukas
    Kloeckner, Roman
    JOURNAL OF THORACIC IMAGING, 2022, 37 (05) : 315 - 322