Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising

被引:9
|
作者
Koons, Emily K. K. [1 ,2 ]
Thorne, Jamison E. E. [1 ]
Huber, Nathan R. R. [1 ]
Chang, Shaojie [1 ]
Rajendran, Kishore [1 ]
McCollough, Cynthia H. H. [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Biomed Engn & Physiol, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
computed tomography; convolutional neural network; coronary artery stents; denoising; photon counting detector; RESTENOSIS;
D O I
10.1002/mp.16415
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundSmall coronary arteries containing stents pose a challenge in CT imaging due to metal-induced blooming artifact. High spatial resolution imaging capability is as the presence of highly attenuating materials limits noninvasive assessment of luminal patency. PurposeThe purpose of this study was to quantify the effective lumen diameter within coronary stents using a clinical photon-counting-detector (PCD) CT in concert with a convolutional neural network (CNN) denoising algorithm, compared to an energy-integrating-detector (EID) CT system. MethodsSeven coronary stents of different materials and inner diameters between 3.43 and 4.72 mm were placed in plastic tubes of diameters 3.96-4.87 mm containing 20 mg/mL of iodine solution, mimicking stented contrast-enhanced coronary arteries. Tubes were placed parallel with or perpendicular to the scanner's z-axis in an anthropomorphic phantom emulating an average-sized patient and scanned with a clinical EID-CT and PCD-CT. EID scans were performed using our standard coronary computed tomography angiography (cCTA) protocol (120 kV, 180 quality reference mAs). PCD scans were performed using the ultra-high-resolution (UHR) mode (120 x 0.2 mm collimation) at 120 kV with tube current adjusted so that CTDIvol was matched to that of EID scans. EID images were reconstructed per our routine clinical protocol (Br40, 0.6 mm thickness), and with the sharpest available kernel (Br69). PCD images were reconstructed at a thickness of 0.6 mm and a dedicated sharp kernel (Br89) which is only possible with the PCD UHR mode. To address increased image noise introduced by the Br89 kernel, an image-based CNN denoising algorithm was applied to the PCD images of stents scanned parallel to the scanner's z-axis. Stents were segmented based on full-width half maximum thresholding and morphological operations, from which effective lumen diameter was calculated and compared to reference sizes measured with a caliper. ResultsSubstantial blooming artifacts were observed on EID Br40 images, resulting in larger stent struts and reduced lumen diameter (effective diameter underestimated by 41% and 47% for parallel and perpendicular orientations, respectively). Blooming artifacts were observed on EID Br69 images with 19% and 31% underestimation of lumen diameter compared to the caliper for parallel and perpendicular scans, respectively. Overall image quality was substantially improved on PCD, with higher spatial resolution and reduced blooming artifacts, resulting in the clearer delineation of stent struts. Effective lumen diameters were underestimated by 9% and 19% relative to the reference for parallel and perpendicular scans, respectively. CNN reduced image noise by about 50% on PCD images without impacting lumen quantification (<0.3% difference). ConclusionThe PCD UHR mode improved in-stent lumen quantification for all seven stents as compared to EID images due to decreased blooming artifacts. Implementation of CNN denoising algorithms to PCD data substantially improved image quality.
引用
收藏
页码:4173 / 4181
页数:9
相关论文
共 50 条
  • [1] Photon-Counting CT High-Resolution Imaging of Coronary Stents
    Mannil, Manoj
    Hickethier, Tilman
    von Spiczak, Jochen
    Baer, Matthias
    Henning, Andre
    Hertel, Madeleine
    Schmidt, Bernhard
    Flohr, Thomas
    Maintz, David
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2018, 53 (03) : 143 - 149
  • [2] Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT
    Rajagopal, Jayasai R.
    Farhadi, Faraz
    Richards, Taylor
    Nikpanah, Moozhan
    Sahbaee, Pooyan
    Shanbhag, Sujata M.
    Bandettini, W. Patricia
    Saboury, Babak
    Malayeri, Ashkan A.
    Pritchard, William F.
    Jones, Elizabeth C.
    Samei, Ehsan
    Chen, Marcus Y.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2021, 3 (05):
  • [3] Dedicated convolutional neural network for noise reduction in ultra-high-resolution photon-counting detector computed tomography
    Huber, Nathan R.
    Ferrero, Andrea
    Rajendran, Kishore
    Baffour, Francis
    Glazebrook, Katrina N.
    Diehn, Felix E.
    Inoue, Akitoshi
    Fletcher, Joel G.
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (17)
  • [4] The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT
    Mergen, Victor
    Sartoretti, Thomas
    Cundari, Giulia
    Serifovic, Medina
    Higashigaito, Kai
    Allmendinger, Thomas
    Schmidt, Bernhard
    Flohr, Thomas
    Manka, Robert
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2023, 58 (11) : 767 - 774
  • [5] Ultra-high resolution CT angiography for the assessment of intracranial stents and flow diverters using photon counting detector CT
    Ludovichetti, Riccardo
    Gorup, Dunja
    Krepuska, Mikos
    Winklhofer, Sebastian
    Thurner, Patrick
    Madjidyar, Jawid
    Flohr, Thomas
    Piccirelli, Marco
    Michels, Lars
    Alkadhi, Hatem
    Mergen, Victor
    Kulcsar, Zsolt
    Schubert, Tilman
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024,
  • [6] High-resolution CT Image Retrieval Using Sparse Convolutional Neural Network
    Lei, Yang
    Xu, Dong
    Zhou, Zhengyang
    Higgins, Kristin
    Dong, Xue
    Liu, Tian
    Shim, Hyunsuk
    Mao, Hui
    Curran, Walter J.
    Yang, Xiaofeng
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [7] Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT Feasibility and Image Characterization
    Mergen, Victor
    Sartoretti, Thomas
    Baer-Beck, Matthias
    Schmidt, Bernhard
    Petersilka, Martin
    Wildberger, Joachim Ernst
    Euler, Andre
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 780 - 788
  • [8] Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience
    Rajendran, Kishore
    Petersilka, Martin
    Henning, Andre
    Shanblatt, Elisabeth
    Marsh, Jeffrey, Jr.
    Thorne, Jamison
    Schmidt, Bernhard
    Flohr, Thomas
    Fletcher, Joel
    McCollough, Cynthia
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (20)
  • [9] Improvement of coronary stent visualization using ultra-high-resolution photon-counting detector CT
    Qin, Le
    Zhou, Shanshui
    Dong, Haipeng
    Li, Jiqiang
    Zhang, Ruiyan
    Yang, Chendie
    Liu, Peng
    Xu, Zhihan
    Yan, Fuhua
    Yang, Wenjie
    EUROPEAN RADIOLOGY, 2024, 34 (10) : 6568 - 6577
  • [10] A High-Resolution Imaging Technique using a Whole-body, Research Photon Counting Detector CT System
    Leng, S.
    Yu, Z.
    Halaweish, A.
    Kappler, S.
    Hahn, K.
    Henning, A.
    Li, Z.
    Lane, J.
    Levin, D. L.
    Jorgensen, S.
    Ritman, E.
    McCollough, C.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783