Photon attenuations of trichloride of gadolinium by Geant4 and XCom: a comparative study

被引:0
|
作者
Saim, A. [1 ]
Belkharroubi, F. [1 ,2 ]
Maroc, F. Z. [1 ]
Blaha, L. F. [2 ]
Ameri, I. [2 ]
Ameri, M. [2 ]
Tebboune, A. [1 ]
Belkaid, M. N. [1 ]
Al-Douri, Y. [3 ,4 ,5 ,6 ,7 ,8 ,9 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Dept Engn Phys, Lab Anal & Applicat Radiat LAAR, Oran, Algeria
[2] Univ DjillaliLiabes, Lab Phys Chem Adv Mat LPCMA, Sidi Bel Abbes, Algeria
[3] Univ Malaya, Nanotechnol & Catalysis Res Ctr NANOCAT, Kuala Lumpur, Malaysia
[4] Bahcesehir Univ, Fac Engn & Nat Sci, Dept Mechatron Engn, Istanbul, Turkiye
[5] Univ Sharjah, Coll Sci, Dept Appl Sci & Astron, Sharjah, U Arab Emirates
[6] Univ Malaya, Nanotechnol & Catalysis Res Ctr NANOCAT, Kuala Lumpur 50603, Malaysia
[7] Bahcesehir Univ, Fac Engn & Nat Sci, Dept Mechatron Engn, TR-34349 Istanbul, Turkiye
[8] Univ Sharjah, Coll Sci, Dept Appl Sci & Astron, POB 27272, Sharjah, U Arab Emirates
[9] Piri Reis Univ, Fac Engn, Dept Mech Engn, Eflatun Sk 8, TR-34940 Istanbul, Turkiye
来源
JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE | 2023年 / 17卷 / 01期
关键词
GdCl3; XRD; WinXCom; Geant4; COEFFICIENTS;
D O I
10.1080/16583655.2023.2168335
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The total mass attenuation coefficient of trichloride gadolinium has been investigated utilizing Geant4 compared with WinXCom simulation data at energies; 1-10 MeV. The simulated results are used to calculate the total cross section, atomic and electronic cross sections. The aim of this work is to characterize new materials and their interactions with radiation in order to be able for using in shielding or detection. The GdCl3 is applied for super-Kamiokande detector of neutrons. From our comparison study, it is found that the mass attenuation coefficient of GdCl3 with those of two detectors of X-ray (Si and CdTe) is very closed. Also, the total mass transfer attenuation coefficient increases as high energies increases at pairs effect production. From our comparison study, we can predict that GdCl3 can be a good detector of X-ray and concluded that this material has shown good interaction with electromagnetic radiations at high energies.
引用
收藏
页数:5
相关论文
共 6 条
  • [1] Elemental characterization of quartzite of Pouma sub-division of Cameroon and radiation attenuation properties based on XCOM and GEANT4 Monte Carlo simulation
    Degbe, Patricia-Laurelle
    Shouop, Cebastien Joel Guembou
    Bongue, Daniel
    Beyinda, Merylle Glawdys
    Moyo, Maurice Ndontchueng
    Njock, Moise Godfroy Kwato
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2022, 177 (7-8): : 688 - 705
  • [2] Photon and electron attenuation parameters of phosphate and borate bioactive glasses by using Geant4 simulations
    Boukhris, Imed
    Kebaili, Imen
    Al-Buriahi, M. S.
    Alalawi, Amani
    Abouhaswa, A. S.
    Tonguc, Baris
    CERAMICS INTERNATIONAL, 2020, 46 (15) : 24435 - 24442
  • [3] The effect of heavy metals on the radiation shielding capabilities of borated polyethylene: a Geant4 study
    Akhdar, Hanan
    PHYSICA SCRIPTA, 2025, 100 (02)
  • [4] Gamma radiation shielding study of tellurite glasses containing V2O5 and Bi2O3 using Geant4 code
    Hendi, A. A.
    Rashad, M.
    Sayyed, M., I
    CERAMICS INTERNATIONAL, 2020, 46 (18) : 28870 - 28876
  • [5] Assessment of gamma-rays and fast neutron beam attenuation features of Er2O3-doped B2O3-ZnO-Bi2O3 glasses using XCOM and simulation codes (MCNP5 and Geant4)
    Lakshminarayana, G.
    Dong, M. G.
    Kumar, Ashok
    Elmahroug, Y.
    Wagh, Akshatha
    Lee, Dong-Eun
    Yoon, Jonghun
    Park, Taejoon
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2019, 125 (11):
  • [6] The impact of Gd2O3 on nuclear safety proficiencies of TeO2-ZnO-Nb2O5 glasses: A GEANT4 Monte Carlo study
    Al-Buriahi, M. S.
    Tonguc, B.
    Perisanoglu, U.
    Kavaz, E.
    CERAMICS INTERNATIONAL, 2020, 46 (15) : 23347 - 23356