Diagnostic biomarkers and aortic dissection: a systematic review and meta-analysis

被引:9
|
作者
Chen, Hongjian [1 ]
Li, Yunjie [2 ]
Li, Zheqian [3 ]
Shi, Yanli [3 ]
Zhu, Haobo [4 ]
机构
[1] Nanjing Med Univ, Childrens Hosp, Dept Infect Dis, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Dept Pediat, Nanjing, Jiangsu, Peoples R China
[3] Nanjing Med Univ, Childrens Hosp, Dept Clin Lab, Nanjing, Jiangsu, Peoples R China
[4] Nanjing Med Univ, Childrens Hosp, Dept Urol, Nanjing, Jiangsu, Peoples R China
关键词
Aortic dissection; Diagnosis; Biomarkers; Systematic review; microRNA; D-DIMER; INTERNATIONAL REGISTRY; ENTRANCE TEAR; MANAGEMENT; FIBRINOGEN; INFARCTION; HELP;
D O I
10.1186/s12872-023-03448-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAortic dissection (AD) is a serious and fatal vascular disease. The earlier the condition of AD patients can be assessed precisely, the more scientifically controlled the patient's condition will be. Therefore, timely and accurate diagnosis is significant for AD. Blood biomarker testing as a method of liquid biopsy can improve the diagnostic efficiency of AD. This study conducted a systematic review of the current blood diagnostic biomarkers of AD.MethodsThe PubMed, Cochrane Library, Web of Science, and Embase electronic databases were systematically searched from inception to January 1, 2023, using the terms "aortic dissection", "serum", "plasma" and "diagnosis". Stata 12.0 software was used to perform Random effects meta-analysis was performed using Stata 12.0 software to determine the effect sizes and corresponding 95% confidence intervals. Then, a summary receiver operator characteristic (SROC) curve was drawn, and the area under the ROC curve (AUC) was calculated.ResultsD-dimer had the best sensitivity and AUC for AD, with values of 0.96 (95% CI: 0.93-0.98) and 0.95 (95% CI: 0.93-0.97), respectively. The sensitivity and AUC values for D-dimer with a cut-off value of 500 ng/mL were 0.97 (95% CI: 0.95-0.99) and 0.94 (95% CI: 0.92-0.96), respectively. In contrast, microRNA had a better specificity value for AD, at 0.79 (95% CI: 0.73-0.83).ConclusionsD-dimer and microRNA have good accuracy in the diagnosis of AD, but the specificity of D-dimer is worse, and studies of microRNA are insufficient. The combination of different biomarkers can improve the diagnostic accuracy. Other blood biomarkers are related to the pathological progression of AD and can be selected according to pathological progress.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Diagnostic biomarkers and aortic dissection: a systematic review and meta-analysis
    Hongjian Chen
    Yunjie Li
    Zheqian Li
    Yanli Shi
    Haobo Zhu
    BMC Cardiovascular Disorders, 23
  • [2] A systematic review and meta-analysis of isolated abdominal aortic dissection
    Wu, Jinlin
    Zafar, Mohammad
    Qiu, Juntao
    Huang, Yan
    Chen, Yuling
    Yu, Cuntao
    Elefteriades, John A.
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (06) : 2046 - +
  • [3] Diagnostic accuracy of transthoracic echocardiography for the identification of proximal aortic dissection: a systematic review and meta-analysis
    Sutarjono, Bayu
    Ahmed, Abrar Justin
    Ivanova, Anna
    Buchel, Brandon
    Rauscher, Joseph
    O'Connell, Alanna
    Riekena, Jeremy
    Gift, Aluko
    Kessel, Matthew
    Grewal, Ekjot
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] Diagnostic accuracy of transthoracic echocardiography for the identification of proximal aortic dissection: a systematic review and meta-analysis
    Bayu Sutarjono
    Abrar Justin Ahmed
    Anna Ivanova
    Brandon Buchel
    Joseph Rauscher
    Alanna O’Connell
    Jeremy Riekena
    Aluko Gift
    Matthew Kessel
    Ekjot Grewal
    Scientific Reports, 13
  • [5] Aortic Dissection and Aortic Aneurysms Associated with Fluoroquinolones: A Systematic Review and Meta-Analysis
    Singh, Sonal
    Nautiyal, Amit
    AMERICAN JOURNAL OF MEDICINE, 2017, 130 (12): : 1449 - +
  • [6] Systematic Review and Meta-Analysis of Diagnostic Biomarkers for Pediatric Pneumonia
    Gunaratnam, Lourdes Cynthia
    Robinson, Joan L.
    Hawkes, Michael T.
    JOURNAL OF THE PEDIATRIC INFECTIOUS DISEASES SOCIETY, 2021, 10 (09) : 891 - 900
  • [7] The association between fluoroquinolones and aortic dissection and aortic aneurysms: a systematic review and meta-analysis
    Wee, Ian
    Chin, Brian
    Syn, Nicholas
    Lee, Keng Siang
    Ng, Jun Jie
    Choong, Andrew M. T. L.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] The association between fluoroquinolones and aortic dissection and aortic aneurysms: a systematic review and meta-analysis
    Ian Wee
    Brian Chin
    Nicholas Syn
    Keng Siang Lee
    Jun Jie Ng
    Andrew M. T. L. Choong
    Scientific Reports, 11
  • [9] Biomarkers for prediction of neurological complications after acute Stanford type A aortic dissection: A systematic review and meta-analysis
    Si, Yi
    Duan, Weixun
    Xie, Jiangang
    Duan, Chujun
    Liu, Shanshou
    Wang, Qianmei
    Zhao, Xiaojun
    Wu, Dan
    Wang, Yifan
    Wang, Lingxiao
    Li, Junjie
    PLOS ONE, 2023, 18 (02):
  • [10] Circulating microRNAs as diagnostic biomarkers for melanoma: a systematic review and meta-analysis
    Wu, Nan
    Sun, Hongyan
    Sun, Qian
    Zhang, Fangqing
    Ma, Lingli
    Hu, Yue
    Cong, Xianling
    BMC CANCER, 2023, 23 (01)