Acute human defibrillation performance of a subcutaneous implantable cardioverter-defibrillator with an additional coil electrode

被引:4
作者
Yap, Sing -Chien [7 ,8 ]
Oosterwerff, Erik F. J. [6 ]
Boersma, Lucas V. A. [1 ,2 ]
van der Stuijt, Willeke [2 ]
Lenssen, Anneke [4 ]
Hahn, Stephen J. [5 ]
Knops, Reinoud E. [3 ]
机构
[1] Erasmus MC, Cardiovasc Inst, Thorax Ctr, Dept Cardiol, Rotterdam, Netherlands
[2] Isala Klin, Dept Cardiol, Zwolle, Netherlands
[3] St Antonious Ziekenhuis, Dept Cardiol, Nieuwegein, Netherlands
[4] Univ Amsterdam, Med Ctr, Dept Cardiol, Amsterdam, Netherlands
[5] Boston Sci, Amsterdam, Netherlands
[6] Boston Sci CRM, St Paul, MN USA
[7] Flevo Hosp, Almere, Netherlands
[8] Erasmus MC, Dept Surg, Doctor Molenwaterpl 40, NL-3015 GD Rotterdam, Netherlands
关键词
Defibrillation; Subcutaneous; Human; Electrodes; Implantable cardioverter-defibrillator; OUTCOMES; TRIAL; ICD;
D O I
10.1016/j.hrthm.2023.08.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The subcutaneous implantable cardioverter-defibrillator (S-ICD) delivers 80 J shocks from an 8 cm left-parasternal coil to a 59 cm(3) left lateral pulse generator (PG). A system that defibrillates with lower energy could significantly reduce PG size. Computer modeling and animal studies suggested that a second shock coil either parallel to the left-parasternal coil or transverse from the xiphoid to the PG pocket would significantly reduce the defibrillation threshold.Objective The purpose of this study was to acutely assess the defibrillation efficacy of parallel and transverse configurations in patients receiving an S-ICD.Methods Testing was performed in patients receiving a conventional S-ICD system. Success at 65 J was required before investigational testing. A second electrode was temporarily inserted from the xiphoid incision connected to the PG with an investigational Y-adapter. Phase 1 (n = 11) tested the parallel configuration. Phase 2 (n = 21) tested both parallel and transverse configurations in random order.Results This study enrolled 35 patients (28 males (80%); mean age 51 +/- 17 years; left ventricular ejection fraction 40% +/- 15%; body mass index 26 +/- 4 kg/m(2); prior myocardial infarction 46%; congestive heart failure 49%; cardiomyopathy 63%). Compared to the conventional S-ICD system, mean shock impedance decreased for both parallel (69 +/- 15 Omega vs 86 +/- 20 Omega; n = 33; P < .001) and transverse (56 +/- 14 Omega vs 81 +/- 21 Omega; n = 20; P < .001) configurations. Shock success rates at 20, 30, and 40 J were 55%, 79%, 97%, and 25%, 70%, 90% for parallel and transverse configurations, respectively. Defibrillation threshold testing was well tolerated with no serious adverse events.Conclusion Adding a second shock coil, particularly in the parallel configuration, significantly reduced the impedance and had a high likelihood of defibrillation success at energies <= 40 J. This may enable the development of a smaller S-ICD.
引用
收藏
页码:1649 / 1656
页数:8
相关论文
共 18 条
  • [1] Factors Associated With High-Voltage Impedance and Subcutaneous Implantable Defibrillator Ventricular Fibrillation Conversion Success
    Amin, Anish K.
    Gold, Michael R.
    Burke, Martin C.
    Knight, Bradley P.
    Rajjoub, Moutie R.
    Duffy, Elizabeth
    Husby, Michael
    Stahl, Wyatt K.
    Weiss, Raul
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (04)
  • [2] An Entirely Subcutaneous Implantable Cardioverter-Defibrillator
    Bardy, Gust H.
    Smith, Warren M.
    Hood, Margaret A.
    Crozier, Ian G.
    Melton, Iain C.
    Jordaens, Luc
    Theuns, Dominic
    Park, Robert E.
    Wright, David J.
    Connelly, Derek T.
    Fynn, Simon P.
    Murgatroyd, Francis D.
    Sperzel, Johannes
    Neuzner, Joerg
    Spitzer, Stefan G.
    Ardashev, Andrey V.
    Oduro, Amo
    Boersma, Lucas
    Maass, Alexander H.
    Van Gelder, Isabelle C.
    Wilde, Arthur A.
    van Dessel, Pascal F.
    Knops, Reinoud E.
    Barr, Craig S.
    Lupo, Pierpaolo
    Cappato, Riccardo
    Grace, Andrew A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) : 36 - 44
  • [3] Is 40 Joules Enough to Successfully Defibrillate With Subcutaneous Implantable Cardioverter-Defibrillators?
    Biffi, Mauro
    Bongiorni, Maria Grazia
    D'Onofrio, Antonio
    Manzo, Michele
    Pieragnoli, Paolo
    Palmisano, Pietro
    Ottaviano, Luca
    Perego, Giovanni Battista
    Pangallo, Antonio
    Lavalle, Carlo
    Bonfantino, Vincenzo
    Nigro, Gerardo
    Landolina, Maurizio Eugenio
    Katsouras, Grigorios
    Diemberger, Igor
    Viani, Stefano
    Bianchi, Valter
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Ziacchi, Matteo
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (06) : 767 - 776
  • [4] Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry The EFFORTLESS Study
    Boersma, Lucas
    Barr, Craig
    Knops, Reinoud
    Theuns, Dominic
    Eckardt, Lars
    Neuzil, Petr
    Scholten, Marcoen
    Hood, Margaret
    Kuschyk, Juergen
    Jones, Paul
    Duffy, Elizabeth
    Husby, Michael
    Stein, Kenneth
    Lambiase, Pier D.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (07) : 830 - 841
  • [5] Implantation technique and optimal subcutaneous defibrillator chest position: a PRAETORIAN score-based study
    Francia, Pietro
    Biffi, Mauro
    Adduci, Carmen
    Ottaviano, Luca
    Migliore, Federico
    De Bonis, Silvana
    Dello Russo, Antonio
    De Filippo, Paolo
    Viani, Stefano
    Bongiorni, Maria Grazia
    Caravati, Fabrizio
    Lavalle, Carlo
    Landolina, Maurizio Eugenio
    Pisano, Ennio
    Giorgi, Davide
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Diemberger, Igor
    [J]. EUROPACE, 2020, 22 (12): : 1822 - 1829
  • [6] Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial
    Gold, Michael R.
    Lambiase, Pier D.
    El-Chami, Mikhael F.
    Knops, Reinoud E.
    Aasbo, Johan D.
    Bongiorni, Maria Grazia
    Russo, Andrea M.
    Deharo, Jean-Claude
    Burke, Martin C.
    Dinerman, Jay
    Barr, Craig S.
    Shaik, Naushad
    Carter, Nathan
    Stoltz, Thomas
    Stein, Kenneth M.
    Brisben, Amy J.
    Boersma, Lucas V. A.
    [J]. CIRCULATION, 2021, 143 (01) : 7 - 17
  • [7] Comparison of single- and dual-coil active pectoral defibrillation lead systems
    Gold, MR
    Olsovsky, MR
    Pelini, MA
    Peters, RW
    Shorofsky, SR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) : 1391 - 1394
  • [8] Hahn SJ, 2022, Heart Rhythm, V19, pS175
  • [9] Perioperative Safety and Early Patient and Device Outcomes Among Subcutaneous Versus Transvenous Implantable Cardioverter Defibrillator Implantations: A Randomized, Multicenter Trial
    Healey, Jeff S.
    Krahn, Andrew D.
    Bashir, Jamil
    Amit, Guy
    Philippon, Francois
    McIntyre, William F.
    Tsang, Bernice
    Joza, Jacqueline
    Exner, Derek, V
    Birnie, David H.
    Sadek, Mouhannad
    Leong, Darryl P.
    Sikkel, Markus
    Korley, Victoria
    Sapp, John L.
    Roux, Jean-Francois
    Lee, Shun Fu
    Wong, Gloria
    Djuric, Angie
    Spears, Danna
    Carroll, Sandra
    Crystal, Eugene
    Hruczkowski, Tom
    Connolly, Stuart J.
    Mondesert, Blandine
    [J]. ANNALS OF INTERNAL MEDICINE, 2022, 175 (12) : 1658 - +
  • [10] Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE)
    Healey, Jeff S.
    Hohnloser, Stefan H.
    Glikson, Michael
    Neuzner, Jorg
    Mabo, Phillipe
    Vinolas, Xavier
    Kautzner, Josef
    O'Hara, Gilles
    VanErven, Lieselot
    Gadler, Fredrik
    Pogue, Janice
    Appl, Ursula
    Gilkerson, Jim
    Pochet, Thierry
    Stein, Kenneth M.
    Merkely, Bela
    Chrolavicius, Susan
    Meeks, Brandi
    Foldesi, Csaba
    Thibault, Bernard
    Connolly, Stuart J.
    [J]. LANCET, 2015, 385 (9970) : 785 - 791