Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience

被引:16
作者
Eleshra, Ahmed [1 ,2 ]
Haulon, Stephan [3 ]
Bertoglio, Luca [4 ,5 ]
Lindsay, Thomas [6 ]
Rohlffs, Fiona [1 ]
Dias, Nuno [7 ]
Tsilimparis, Nikolaos [1 ,8 ]
Panuccio, Giuseppe [1 ]
Koelbel, Tilo [1 ]
机构
[1] Univ Med Ctr Eppendorf, Univ Heart & Vasc Ctr, German Aort Ctr, Hamburg, Germany
[2] Mansoura Univ, Fac Med, Dept Vasc Surg, Mansoura, Egypt
[3] Hosp Marie Lannelongue, Paris, France
[4] Osped San Raffaele, Milan, Italy
[5] Univ & ASST Spedali Civili Hosp Brescia, Dept Sperimental & Clin Sci DSCS, Div Vasc Surg, Brescia, Italy
[6] Univ Hlth Network, Toronto, ON, Canada
[7] Skane Univ Hosp, Malmo, Sweden
[8] LMU, Univ Hosp, Munich, Germany
关键词
Aneurysm; Aortic dissection; Aortic remodelling; Endovascular repair; False lumen occlusion; Thoracic endovascular aortic repair; ENDOVASCULAR REPAIR; EMBOLIZATION; THROMBOSIS; BRANCHES; OUTCOMES; DEVICE;
D O I
10.1016/j.ejvs.2023.03.020
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To evaluate early and midterm outcomes of the Candy Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection (AD) in a more real world cohort of patients from an international multicentre registry. Methods: A multicentre retrospective study was conducted of all consecutive patients from the contributing centres with subacute and chronic AD treated with the CP technique from October 2013 to April 2020 at 18 centres.Results: A custom made CP was used in 155 patients (92 males, mean age 62 + 11 years). Fourteen (9%) presented with ruptured false lumen aneurysms. Technical success was achieved in all patients (100%). Clinical success was achieved in 138 patients (89%). The median hospital stay was 7 days (1 -77). The 30 day mortality rate was 3% (n = 5). Stroke occurred in four patients (3%). Spinal cord ischaemia occurred in three patients (2%). The 30 day computed tomography angiogram (CTA) confirmed successful CP placement at the intended level in all patients. Early complete FL occlusion was achieved in 120 patients (77%). Early (30 day) CP related re-intervention was required in four patients (3%). The early (30 day) stent graft related re-intervention rate was 8% (n = 12). Follow up CTA was available in 142 patients (92%), with a median follow up of 23 months (6 -87). Aneurysmal regression was achieved in 68 of 142 patients (47%); the aneurysm diameter remained stable in 69 of 142 patients (49%) and increased in five of 142 patients (4%). A higher rate of early FL occlusion was detected in the largest volume centre patients (50 [88%] vs. 70 [71%] from other centres; p = .019). No other differences in outcome were identified regarding volume of cases or learning curve.Conclusion: This international CP technique experience confirmed its feasibility and low mortality and morbidity rates. Aortic remodelling and false lumen thrombosis rates were high and support the concept of distal FL occlusion in AD using the CP technique.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 29 条
  • [1] Aortic Remodeling After Custom-Made Candy-Plug for Distal False Lumen Occlusion in Aortic Dissection
    Eleshra, Ahmed
    Rohlffs, Fiona
    Spanos, Konstantinos
    Panuccio, Giuseppe
    Heidemann, Franziska
    Tsilimparis, Nikolaos
    Kolbel, Tilo
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (03) : 399 - 406
  • [2] Candy-Plug Generation II for False Lumen Occlusion in Chronic Aortic Dissection: Feasibility and Early Results
    Eleshra, Ahmed
    Koelbel, Tilo
    Tsilimparis, Nikolaos
    Panuccio, Giuseppe
    Scheerbaum, Martin
    Debus, E. Sebastian
    Mogensen, John
    Rohlffs, Fiona
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (06) : 782 - 786
  • [3] Eleshra Ahmed Sameh, 2018, Korean J Thorac Cardiovasc Surg, V51, P286, DOI 10.5090/kjtcs.2018.51.4.286
  • [4] Stentless thoracic endovascular aortic repair of a chronic DeBakey IIIb aneurysm
    Eleshra, Ahmed Sameh
    Heo, Woon
    Lee, Kwang-Hun
    Song, Suk-Won
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (03) : E67 - E68
  • [5] A pitfall of false lumen embolization in chronic aortic dissection: intimal injury caused by the embolization device edge
    Furukawa, Tomokuni
    Uchida, Naomichi
    Yamane, Yoshitaka
    Yamada, Kazunori
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (01) : 153 - 155
  • [6] The Number of Preoperative Abdominal False Lumen-perfused Small Branches Is Related to Abdominal Aortic Remodeling after Thoracic Endovascular Aortic Repair for Type B Aortic Dissection
    Ge, Yangyang
    Lv, Xiaomeng
    Ge, Xiaohu
    Miao, Jianhang
    Fan, Weidong
    Rong, Dan
    Guo, Wei
    [J]. ANNALS OF VASCULAR SURGERY, 2021, 71 : 56 - 64
  • [7] Aortic False Lumen Thrombosis Induction by Embolotherapy (AFTER) Following Endovascular Repair of Aortic Dissection
    Hofferberth, Sophie C.
    Nixon, Ian K.
    Mossop, Peter J.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (04) : 538 - 545
  • [8] Outcomes after false lumen embolization with covered stent devices in chronic dissection
    Idrees, Jahanzaib
    Roselli, Eric E.
    Shafii, Susan
    Reside, Joshua
    Lytle, Bruce W.
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (06) : 1507 - 1513
  • [9] Kölbe T, 2014, J ENDOVASC THER, V21, P117, DOI 10.1583/13-4463MR-R.1
  • [10] Kölbel T, 2013, J CARDIOVASC SURG, V54, P81