ADEPT: Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs

被引:3
|
作者
Shafieizargar, Banafshe [1 ,2 ]
Jeurissen, Ben [1 ,2 ]
Poot, Dirk H. J. [3 ]
Klein, Stefan [3 ]
Van Audekerke, Johan [2 ,4 ]
Verhoye, Marleen [2 ,4 ]
den Dekker, Arnold J. [1 ,2 ]
Sijbers, Jan [1 ,2 ]
机构
[1] Univ Antwerp, Dept Phys, Iimec Vis Lab, Univ Pl 1,DN 103, B-2610 Antwerp, Belgium
[2] Univ Antwerp, NEURO Res Ctr Excellence, Antwerp, Belgium
[3] Erasmus MC, Dept Radiol & Nucl Med, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
[4] Univ Antwerp, Dept Biomed Sci, Bioimaging Lab, Antwerp, Belgium
基金
欧盟地平线“2020”;
关键词
diffusion MRI; model-based reconstruction; multi-shot EPI; phase correction; QMRI; MODEL-BASED RECONSTRUCTION; RICIAN DISTRIBUTION; WEIGHTED-MRI; RESOLUTION; MOTION; CONVERGENCE; ARTIFACTS; SENSE; EPI;
D O I
10.1002/mrm.29398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To introduce a novel imaging and parameter estimation framework for accurate multi-shot diffusion MRI. Theory and Methods We propose a new framework called ADEPT (Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs) that enables fast diffusion MRI by allowing diffusion contrast settings to change between shots in a multi-shot EPI acquisition (i.e., intra-scan modulation). The framework estimates diffusion parameter maps directly from the acquired intra-scan modulated k-space data, while simultaneously accounting for shot-to-shot phase inconsistencies. The performance of the estimation framework is evaluated using Monte Carlo simulation studies and in-vivo experiments and compared to that of reference methods that rely on parallel imaging for shot-to-shot phase correction. Results Simulation and real-data experiments show that ADEPT yields more accurate and more precise estimates of the diffusion metrics in multi-shot EPI data in comparison with the reference methods. Conclusion ADEPT allows fast multi-shot EPI diffusion MRI without significantly degrading the accuracy and precision of the estimated diffusion maps.
引用
收藏
页码:396 / 410
页数:15
相关论文
共 50 条
  • [21] Correction of Shearing Distortions in Echo-Planar Imaging
    Liu, Guoxiang
    Oshio, Koichi
    Ogawa, Seiji
    Murata, Tsutomu
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (07) : 2628 - 2634
  • [22] Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar Imaging
    Zaharchuk, G.
    Saritas, E. U.
    Andre, J. B.
    Chin, C. T.
    Rosenberg, J.
    Brosnan, T. J.
    Shankaranarayan, A.
    Nishimura, D. G.
    Fischbein, N. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (05) : 813 - 820
  • [23] Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging
    Reeder, SB
    Atalar, E
    Bolster, BD
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 429 - 439
  • [24] Pseudo multishot echo-planar imaging for geometric distortion improvement
    Chen, Hao
    Dai, Ke
    Bao, Jianfeng
    Zhong, Sijie
    Hu, Chenxi
    Liu, Yiling
    Zhang, Zhiyong
    NMR IN BIOMEDICINE, 2023, 36 (05)
  • [25] Diffusion-weighted imaging with simultaneous multi-slice echo-planar technique for the diagnosis of breast magnetic resonance imaging
    Machida, Youichi
    Nomura, Kyoko
    Shimauchi, Akiko
    Kato, Yoshiaki
    Nagatsuka, Machiko
    Fukuma, Eisuke
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (04) : 358 - 364
  • [26] Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver
    Kim, Yeun-Yoon
    Kim, Myeong-Jin
    Gho, Sung-Min
    Seo, Nieun
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
  • [27] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [28] Distortion-Free Diffusion Imaging Using Self-Navigated Cartesian Echo-Planar Time Resolved Acquisition and Joint Magnitude and Phase Constrained Reconstruction
    Dai, Erpeng
    Lee, Philip K.
    Dong, Zijing
    Fu, Fanrui
    Setsompop, Kawin
    McNab, Jennifer A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (01) : 63 - 74
  • [29] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [30] Diffusion-weighted magnetic resonance imaging in rat kidney using two-dimensional navigated, interleaved echo-planar imaging at 7.0 T
    Liu, Qiang
    Xu, Zhongbiao
    Zhao, Kaixuan
    Hoge, W. Scott
    Zhang, Xinyuan
    Mei, Yingjie
    Lu, Qiqi
    Niendorf, Thoralf
    Feng, Yanqiu
    NMR IN BIOMEDICINE, 2022, 35 (05)