Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine

被引:6
作者
Conrads, Nora [1 ]
Grunz, Jan-Peter [1 ]
Huflage, Henner [1 ]
Luetkens, Karsten Sebastian [1 ]
Feldle, Philipp [1 ]
Grunz, Katharina [2 ]
Koehler, Stefan [3 ,4 ]
Westermaier, Thomas [3 ,5 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Standort Juliusspital, Klinikum Wurzburg Mitte, Dept Orthoped & Trauma Surg, Juliuspromenade 19, D-97070 Wurzburg, Germany
[3] Univ Hosp Wurzburg, Dept Neurosurg, Josef Schneider Str 11, D-97080 Wurzburg, Germany
[4] Die Neurochirurg Praxis, Eichhornstr 28, D-97070 Wurzburg, Germany
[5] Helios Amper Klinikum Dachau, Dept Neurosurg, Krankenhausstr 15, D-85221 Dachau, Germany
关键词
Pedicle screws; Vertebral pedicles; Fluoroscopy; Neuronavigation; Spine; FREE-HAND; NAVIGATION; GUIDANCE; SURGERY;
D O I
10.1007/s00402-022-04514-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities. Materials and methods Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded. Results Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up. Conclusions Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required.
引用
收藏
页码:3007 / 3013
页数:7
相关论文
共 26 条
  • [1] Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    Amiot, LP
    Lang, K
    Putzier, M
    Zippel, H
    Labelle, H
    [J]. SPINE, 2000, 25 (05) : 606 - 614
  • [2] Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures
    Beck, Markus
    Mittlmeier, Thomas
    Gierer, Philip
    Harms, Christoph
    Gradl, Georg
    [J]. EUROPEAN SPINE JOURNAL, 2009, 18 (10) : 1469 - 1477
  • [3] Intraoperative image guidance compared with free-hand methods in adolescent idiopathic scoliosis posterior spinal surgery: a systematic review on screw-related complications and breach rates
    Chan, Andrew
    Parent, Eric
    Narvacan, Karl
    San, Cindy
    Lou, Edmond
    [J]. SPINE JOURNAL, 2017, 17 (09) : 1215 - 1229
  • [4] Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques
    Gelalis, Ioannis D.
    Paschos, Nikolaos K.
    Pakos, Emilios E.
    Politis, Angelos N.
    Arnaoutoglou, Christina M.
    Karageorgos, Athanasios C.
    Ploumis, Avraam
    Xenakis, Theodoros A.
    [J]. EUROPEAN SPINE JOURNAL, 2012, 21 (02) : 247 - 255
  • [5] The Arrival of Robotics in Spine Surgery A Review of the Literature
    Ghasem, Alexander
    Sharma, Akhil
    Greif, Dylan N.
    Alam, Milad
    Al Maaieh, Motasem
    [J]. SPINE, 2018, 43 (23) : 1670 - 1677
  • [6] Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures: a prospective trial
    Heintel, Timo Michael
    Berglehner, Andreas
    Meffert, Rainer
    [J]. EUROPEAN SPINE JOURNAL, 2013, 22 (03) : 495 - 502
  • [7] Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement
    Ishikawa, Yoshimoto
    Kanemura, Tokumi
    Yoshida, Go
    Ito, Zenya
    Muramoto, Akio
    Ohno, Shuichiro
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (05) : 606 - 611
  • [8] Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation
    Kim, Terrence T.
    Drazin, Doniel
    Shweikeh, Faris
    Pashman, Robert
    Johnson, J. Patrick
    [J]. NEUROSURGICAL FOCUS, 2014, 36 (03)
  • [9] Improved accuracy of computer-assisted cervical pedicle screw insertion
    Kotani, Y
    Abumi, K
    Ito, M
    Minami, A
    [J]. JOURNAL OF NEUROSURGERY, 2003, 99 (03) : 257 - 263
  • [10] Relevance of spinal navigation in reconstructive surgery of the cervical spine
    Kothe, R.
    Richter, M.
    [J]. ORTHOPADE, 2018, 47 (06): : 518 - 525