Localization of Low- and High-Frequency Sounds in Cochlear Implant Recipients Using a Contralateral Hearing Aid

被引:0
|
作者
Zelger, Philipp [1 ]
Zorowka, Patrick [1 ]
Schmutzhard, Joachim [2 ]
Galvan, Oliver [1 ]
Rossi, Sonja [1 ]
Stephan, Kurt [1 ]
Seebacher, Josef [1 ]
机构
[1] Med Univ Innsbruck, Dept Hearing Speech & Voice Disorders, Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Otorhinolaryngol, Innsbruck, Austria
关键词
Asymmetric hearing loss; Bimodal hearing; Cochlear implant; Hearing aid; Sound localization; HORIZONTAL LOCALIZATION; SPEECH-INTELLIGIBILITY; IDENTIFICATION; USERS;
D O I
10.1097/MAO.0000000000004090
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and ObjectivesThe ability to localize sounds is partly recovered in patients using a cochlear implant (CI) in one ear and a hearing aid (HA) on the contralateral side. Binaural processing seems effective at least to some extent, despite the difference between electric and acoustic stimulation in each ear. To obtain further insights into the mechanisms of binaural hearing in these listeners, localization of low- and high-frequency sounds was tested.Study DesignThe study used a within-subject design, where participants were tasked with localizing sound sources in the horizontal plane. The experiment was conducted in an anechoic chamber, where an array of seven loudspeakers was mounted along the 24 azimuthal angle span from -90 degrees to +90 degrees. Stimuli were applied with different frequencies: broadband noise and high- and low-frequency noise.SubjectsTen CI recipients participated in the study. All had an asymmetric hearing loss with a CI in the poorer ear and an HA on the contralateral side.Main Outcome MeasuresAccuracy of sound localization in terms of angular error and percentage of correct localization scores.ResultsThe median angular error was 40 degrees in bimodal conditions for both broadband noise and high-frequency noise stimuli. The angular error increased to 47 degrees for low-frequency noise stimuli. In the unilaterally aided condition with an HA, only a median angular error of 78 degrees was observed.ConclusionsIrrespective of the frequency composition of the stimuli, this group of bimodal listeners showed some ability to localize sounds. Angular errors were larger than those reported in the literature for bilateral CI users or single-sided deaf listeners with a CI. In the unilateral listening condition with HA, only localization of sounds was not possible for most subjects.
引用
收藏
页码:e228 / e233
页数:6
相关论文
共 50 条
  • [21] Results in Adult Cochlear Implant Recipients With Varied Asymmetric Hearing: A Prospective Longitudinal Study of Speech Recognition, Localization, and Participant Report
    Firszt, Jill B.
    Reeder, Ruth M.
    Holden, Laura K.
    Dwyer, Noel Y.
    Gotter, Brenda
    Mispagel, Karen
    Potts, Lisa
    Vanderhoof, Sallie
    Holden, Tim
    Brenner, Chris
    Strube, Mike
    Buchman, Craig
    Chole, Richard
    Drescher, Andrew
    Goebel, Joel
    Hullar, Tim
    McJunkin, Jonathan
    Neely, Gail
    Cowdrey, Lisa
    Lewis, Kristen
    Frazier, Heidi
    Zlomke, Sarah
    Cullen, Robert
    Luetje, Charles
    EAR AND HEARING, 2018, 39 (05) : 845 - 862
  • [22] Self-Reported Usage, Functional Benefit, and Audiologic Characteristics of Cochlear Implant Patients Who Use a Contralateral Hearing Aid
    Neuman, Arlene C.
    Waltzman, Susan B.
    Shapiro, William H.
    Neukam, Jonathan D.
    Zeman, Annette M.
    Svirsky, Mario A.
    TRENDS IN HEARING, 2017, 21 : 1 - 14
  • [23] The Use of Frequency Compression by Cochlear Implant Recipients with Postoperative Acoustic Hearing
    McDermotet, Hugh
    Henshall, Katherine
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2010, 21 (06) : 380 - 389
  • [24] Using hearing aid adaptive directional microphones to enhance cochlear implant performance
    Chung, King
    Zeng, Fan-Gang
    HEARING RESEARCH, 2009, 250 (1-2) : 27 - 37
  • [25] Emotional Responses to Non-Speech Sounds for Hearing-aid and Bimodal Cochlear-Implant Listeners
    Tawdrous, Marina M.
    D'Onofrio, Kristen L.
    Gifford, Rene
    Picou, Erin M.
    TRENDS IN HEARING, 2022, 26
  • [26] Effects of Low Frequency Residual Hearing on Music Perception and Psychoacoustic Abilities in Pediatric Cochlear Implant Recipients
    Yuksel, Mustafa
    Meredith, Margaret A.
    Rubinstein, Jay T.
    FRONTIERS IN NEUROSCIENCE, 2019, 13
  • [27] Simulations of high-frequency vocoder on Mandarin speech recognition for acoustic hearing preserved cochlear implant
    Wu, Tsung-Chen
    Chi, Tai-Shih
    Lee, Chia-Fone
    18TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION (INTERSPEECH 2017), VOLS 1-6: SITUATED INTERACTION, 2017, : 196 - 200
  • [28] From Hearing with a Cochlear Implant and a Contralateral Hearing Aid (CI/HA) to Hearing with Two Cochlear Implants (CI/CI): A Within-Subject Design Comparison
    Luntz, Michal
    Egra-Dagan, Dana
    Attias, Joseph
    Yehudai, Noam
    Most, Tova
    Shpak, Talma
    OTOLOGY & NEUROTOLOGY, 2014, 35 (10) : 1682 - 1690
  • [29] Bimodal Benefits for Lexical Tone Recognition: An Investigation on Mandarin-speaking Preschoolers with a Cochlear Implant and a Contralateral Hearing Aid
    Zhang, Hao
    Zhang, Jing
    Ding, Hongwei
    Zhang, Yang
    BRAIN SCIENCES, 2020, 10 (04)
  • [30] The RetroX auditory implant for high-frequency hearing loss
    Garin, P
    Genard, F
    Galle, C
    Jamart, J